Package that tests if constructions can be conditionally removed
Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).
Name | Description |
---|---|
BaseClasses | Package with base classes for Buildings.Rooms.Examples.TestConditionalConstructions |
OnlyExteriorWallNoWindow | Test model for room model |
OnlyExteriorWallWithWindow | Test model for room model |
OnlyExteriorWallWithWindowExteriorShade | Test model for room model |
OnlyExteriorWallWithWindowInteriorShade | Test model for room model |
OnlyPartition | Test model for room model |
OnlyConstructionBoundary | Test model for room model |
OnlySurfaceBoundary | Test model for room model |
Test model for room model
Extends from Modelica.Icons.Example (Icon for runnable examples), BaseClasses.PartialTestModel (Partial model that is used to build the test cases).
Type | Name | Default | Description |
---|---|---|---|
Integer | nConExt | 1 | Number of exterior constructions that do not have a window |
Integer | nConExtWin | 0 | Number of exterior constructions that do have a window |
Integer | nConPar | 0 | Number of partition constructions |
Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room |
Integer | nSurBou | 0 | Number of surface that are connected to the room air volume |
Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
Brick120 | matLayPar | Construction material for partition walls | |
DoubleClearAir13Clear | glaSys | Data record for the glazing system |
Test model for room model
Extends from Modelica.Icons.Example (Icon for runnable examples), BaseClasses.PartialTestModel (Partial model that is used to build the test cases).
Type | Name | Default | Description |
---|---|---|---|
Integer | nConExt | 0 | Number of exterior constructions that do not have a window |
Integer | nConExtWin | 2 | Number of exterior constructions that do have a window |
Integer | nConPar | 0 | Number of partition constructions |
Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room |
Integer | nSurBou | 0 | Number of surface that are connected to the room air volume |
Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
Brick120 | matLayPar | Construction material for partition walls | |
DoubleClearAir13Clear | glaSys | Data record for the glazing system |
Test model for room model
Extends from Modelica.Icons.Example (Icon for runnable examples), BaseClasses.PartialTestModel (Partial model that is used to build the test cases).
Type | Name | Default | Description |
---|---|---|---|
Integer | nConExt | 0 | Number of exterior constructions that do not have a window |
Integer | nConExtWin | 2 | Number of exterior constructions that do have a window |
Integer | nConPar | 0 | Number of partition constructions |
Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room |
Integer | nSurBou | 0 | Number of surface that are connected to the room air volume |
Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
Brick120 | matLayPar | Construction material for partition walls |
Test model for room model
Extends from Modelica.Icons.Example (Icon for runnable examples), BaseClasses.PartialTestModel (Partial model that is used to build the test cases).
Type | Name | Default | Description |
---|---|---|---|
Integer | nConExt | 0 | Number of exterior constructions that do not have a window |
Integer | nConExtWin | 2 | Number of exterior constructions that do have a window |
Integer | nConPar | 0 | Number of partition constructions |
Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room |
Integer | nSurBou | 0 | Number of surface that are connected to the room air volume |
Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
Brick120 | matLayPar | Construction material for partition walls |
Test model for room model
Extends from Modelica.Icons.Example (Icon for runnable examples), BaseClasses.PartialTestModel (Partial model that is used to build the test cases).
Type | Name | Default | Description |
---|---|---|---|
Integer | nConExt | 0 | Number of exterior constructions that do not have a window |
Integer | nConExtWin | 0 | Number of exterior constructions that do have a window |
Integer | nConPar | 1 | Number of partition constructions |
Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room |
Integer | nSurBou | 0 | Number of surface that are connected to the room air volume |
Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
Brick120 | matLayPar | Construction material for partition walls | |
DoubleClearAir13Clear | glaSys | Data record for the glazing system |
Test model for room model
Extends from Modelica.Icons.Example (Icon for runnable examples), BaseClasses.PartialTestModel (Partial model that is used to build the test cases).
Type | Name | Default | Description |
---|---|---|---|
Integer | nConExt | 0 | Number of exterior constructions that do not have a window |
Integer | nConExtWin | 0 | Number of exterior constructions that do have a window |
Integer | nConPar | 0 | Number of partition constructions |
Integer | nConBou | 1 | Number of surface that are connected to constructions that are modeled inside the room |
Integer | nSurBou | 0 | Number of surface that are connected to the room air volume |
Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
Brick120 | matLayPar | Construction material for partition walls | |
DoubleClearAir13Clear | glaSys | Data record for the glazing system |
Test model for room model
Extends from Modelica.Icons.Example (Icon for runnable examples), BaseClasses.PartialTestModel (Partial model that is used to build the test cases).
Type | Name | Default | Description |
---|---|---|---|
Integer | nConExt | 0 | Number of exterior constructions that do not have a window |
Integer | nConExtWin | 0 | Number of exterior constructions that do have a window |
Integer | nConPar | 0 | Number of partition constructions |
Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room |
Integer | nSurBou | 1 | Number of surface that are connected to the room air volume |
Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
Brick120 | matLayPar | Construction material for partition walls | |
DoubleClearAir13Clear | glaSys | Data record for the glazing system |