Buildings.Electrical.DC.Sources
Package with models for DC sources
Information
This package contains models that represent different types of DC sources.
Extends from Modelica.Icons.SourcesPackage (Icon for packages containing sources).
Package Content
Name | Description |
---|---|
ConstantVoltage | Model of a constant DC voltage source |
PVSimple | Simple PV model |
PVSimpleOriented | Simple PV model with orientation |
VoltageSource | Model of a generoic DC voltage source |
WindTurbine | Wind turbine with power output based on table as a function of wind speed |
Examples | Package with example models |
BaseClasses | Package with base classes for DC sources |
Buildings.Electrical.DC.Sources.ConstantVoltage
Model of a constant DC voltage source
Information
This model represents a simple DC voltage source with constant voltage.
Extends from Buildings.Electrical.Interfaces.Source (Partial model of a generic source.).
Parameters
Type | Name | Default | Description |
---|---|---|---|
replaceable package PhaseSystem | OnePhase | Phase system | |
Voltage | V | Value of constant voltage [V] | |
Reference Parameters | |||
Boolean | potentialReference | true | Serve as potential root for the reference angle theta |
Boolean | definiteReference | false | Serve as definite root for the reference angle theta |
Connectors
Type | Name | Description |
---|---|---|
replaceable package PhaseSystem | Phase system | |
NegativePin | n | Negative pin |
Modelica definition
Buildings.Electrical.DC.Sources.PVSimple
Simple PV model
Information
Model of a simple photovoltaic array.
This model computes the power as
P=A fact η G
where A is the panel area, fact is the fraction of the aperture area, η is the panel efficiency and G is the total solar irradiation. This power is equal to P = v i, where v is the voltage across the panel and i is the current that flows through the panel.
To avoid a large voltage drop the panel electric connector, it is recommended to use this model together with a model that prescribes the voltage. See Buildings.Electrical.DC.Sources.Examples.PVSimple.
Note: This model takes as input the total solar irradiation on the panel. This has to be computed converting the incoming radiation to take tilt and azimuth into account.
Extends from Buildings.Electrical.Interfaces.PartialPV (Base model for a PV system).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Area | A | Gross surface area (including area not covered with active PV cells) [m2] | |
Real | fAct | 0.9 | Fraction of surface area with active solar cells [1] |
Real | eta | 0.12 | Module conversion efficiency [1] |
replaceable package PhaseSystem | PartialPhaseSystem | Phase system | |
Nominal conditions | |||
Voltage | V_nominal | Nominal voltage (V_nominal >= 0) [V] |
Connectors
Type | Name | Description |
---|---|---|
output RealOutput | P | Generated power [W] |
replaceable package PhaseSystem | Phase system | |
input RealInput | G | Total solar irradiation per unit area [W/m2] |
Modelica definition
Buildings.Electrical.DC.Sources.PVSimpleOriented
Simple PV model with orientation
Information
Model of a simple photovoltaic array.
This model computes the power as
P=A fact η G
where A is the panel area, fact is the fraction of the aperture area, η is the panel efficiency and G is the total solar irradiation, which is the sum of direct and diffuse irradiation. The model takes into account the location and the orientation of the PV panel, specified by the surface tilt, latitude and azimuth.
This power is equal to P = v i, where v is the voltage across the panel and i is the current that flows through the panel.
To avoid a large voltage drop the panel electric connector, it is recommended to use this model together with a model that prescribes the voltage. See Buildings.Electrical.DC.Sources.Examples.PVSimpleOriented.
This model takes as an input the direct and diffuse solar radiation from the weather data bus.
Extends from Buildings.Electrical.Interfaces.PartialPVOriented (Base model of a PV system with orientation).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Area | A | Gross surface area (including area not covered with active PV cells) [m2] | |
Real | fAct | 0.9 | Fraction of surface area with active solar cells [1] |
Real | eta | 0.12 | Module conversion efficiency [1] |
replaceable package PhaseSystem | PartialPhaseSystem | Phase system | |
Orientation | |||
Angle | til | Surface tilt [rad] | |
Angle | azi | Surface azimuth [rad] | |
Nominal conditions | |||
Voltage | V_nominal | Nominal voltage (V_nominal >= 0) [V] |
Connectors
Type | Name | Description |
---|---|---|
output RealOutput | P | Generated power [W] |
replaceable package PhaseSystem | Phase system | |
Bus | weaBus | Weather data |
Modelica definition
Buildings.Electrical.DC.Sources.VoltageSource
Model of a generoic DC voltage source
Information
This model represents a simple DC voltage source with variable voltage.
Extends from Buildings.Electrical.Interfaces.VariableVoltageSource (Partial model of a generic variable voltage source.).
Parameters
Type | Name | Default | Description |
---|---|---|---|
replaceable package PhaseSystem | OnePhase | Phase system | |
Boolean | use_V_in | true | If true, the voltage is an input |
Reference Parameters | |||
Boolean | potentialReference | true | Serve as potential root for the reference angle theta |
Boolean | definiteReference | false | Serve as definite root for the reference angle theta |
Initialization | |||
Voltage | V.start | 1 | Value of constant voltage [V] |
RealInput | V_in.start | 1 | Input voltage [V] |
Connectors
Type | Name | Description |
---|---|---|
replaceable package PhaseSystem | Phase system | |
NegativePin | n | Negative pin |
Initialization | ||
input RealInput | V_in | Input voltage [V] |
Modelica definition
Buildings.Electrical.DC.Sources.WindTurbine
Wind turbine with power output based on table as a function of wind speed
Information
Model of a wind turbine whose power is computed as a function of wind-speed as defined in a table.
Input to the model is the local wind speed.
The model requires the specification of a table that maps wind speed in meters per second to generated
power Pt in Watts.
The model has a parameter called scale
with a default value of one
that can be used to scale the power generated by the wind turbine.
The generated DC electrical power is
P = Pt scale = v i,
where v is the voltage and i is the current.
For example, the following specification (with default scale=1
) of a wind turbine
WindTurbine_Table tur( table=[3.5, 0; 5.5, 100; 12, 900; 14, 1000; 25, 1000]) "Wind turbine";
yields the performance shown below. In this example, the cut-in wind speed is 3.5 meters per second, and the cut-out wind speed is 25 meters per second, as entered by the first and last entry of the wind speed column. Below and above these wind speeds, the generated power is zero.
Extends from Buildings.Electrical.Interfaces.PartialWindTurbine (Partial model of a wind turbine with power output based on table as a function of wind speed).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Real | scale | 1 | Scaling factor, used to allow adjusting the power output without changing the table |
Boolean | tableOnFile | false | true, if table is defined on file or in function usertab |
Real | table[:, 2] | [3.5, 0; 5.5, 0.1; 12, 0.9; ... | Table of generated power (first column is wind speed, second column is power) |
String | tableName | "NoName" | Table name on file or in function usertab (see documentation) |
String | fileName | "NoName" | File where matrix is stored |
replaceable package PhaseSystem | PartialPhaseSystem | Phase system | |
Wind correction | |||
Real | h | Height over ground | |
Height | hRef | 10 | Reference height for wind measurement [m] |
Real | nWin | 0.4 | Height exponent for wind profile calculation |
Nominal conditions | |||
Voltage | V_nominal | Nominal voltage (V_nominal >= 0) [V] |
Connectors
Type | Name | Description |
---|---|---|
input RealInput | vWin | Steady wind speed [m/s] |
output RealOutput | P | Generated power [W] |
replaceable package PhaseSystem | Phase system |