Collection of models that illustrate model use and test models
Information
This package contains examples for the use of models that can be found in
Buildings.Fluid.Sources.
Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).
Package Content
Name |
Description |
MassFlowSource_WeatherData
|
Test model for source (sink) with weather bus |
Outside
|
Test model for source and sink with outside weather data |
Outside_Cp
|
Test model for source and sink with outside weather data and wind pressure |
Outside_CpLowRise
|
Test model for source and sink with outside weather data and wind pressure |
TraceSubstancesFlowSource
|
|
Test model for source (sink) with weather bus
Information
This model demonstrates how to connect fluid flow components to a
boundary condition that has environmental conditions as
obtained from a weather file.
The model draws a constant mass flow rate of outside air through
its components.
Extends from Modelica.Icons.Example (Icon for runnable examples).
Modelica definition
model MassFlowSource_WeatherData
extends Modelica.Icons.Example;
package Medium =
Buildings.Media.Air ;
Buildings.BoundaryConditions.WeatherData.ReaderTMY3 weaDat(filNam="modelica://Buildings/Resources/weatherdata/USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.mos");
Buildings.Fluid.Sources.MassFlowSource_WeatherData sin_with_h(
redeclare package Medium = Medium,
m_flow=-1,
nPorts=1) ;
Buildings.Fluid.Sources.Outside bou(
redeclare package Medium = Medium, nPorts
=1) ;
Buildings.Fluid.Sensors.RelativeHumidityTwoPort senRelHum(
redeclare package Medium = Medium,
m_flow_nominal=1,
tau=0) ;
Buildings.Fluid.Sensors.MassFractionTwoPort senMasFra(
redeclare package Medium = Medium,
m_flow_nominal=1,
tau=0) ;
Sensors.TemperatureTwoPort senTem(
redeclare package Medium = Medium,
m_flow_nominal=1,
tau=0) ;
equation
connect(bou.ports[1], senRelHum.port_a);
connect(senRelHum.port_b, senMasFra.port_a);
connect(senMasFra.port_b, senTem.port_a);
connect(senTem.port_b, sin_with_h.ports[1]);
connect(weaDat.weaBus, bou.weaBus);
connect(weaDat.weaBus, sin_with_h.weaBus);
end MassFlowSource_WeatherData;
Test model for source and sink with outside weather data
Information
This model demonstrates how to connect fluid flow component to a
boundary condition that has environmental conditions as
obtained from a weather file.
The model draws a constant mass flow rate of outside air through
its components.
Extends from Modelica.Icons.Example (Icon for runnable examples).
Modelica definition
model Outside
extends Modelica.Icons.Example;
package Medium =
Buildings.Media.Air ;
Buildings.Fluid.Sources.Outside bou(
redeclare package Medium = Medium, nPorts
=1) ;
Buildings.BoundaryConditions.WeatherData.ReaderTMY3 weaDat(filNam="modelica://Buildings/Resources/weatherdata/USA_IL_Chicago-OHare.Intl.AP.725300_TMY3.mos");
Buildings.Fluid.Sources.MassFlowSource_T sin(
redeclare package Medium = Medium,
m_flow=-1,
nPorts=1) ;
Buildings.Fluid.Sensors.TemperatureTwoPort senTem(
redeclare package Medium = Medium,
m_flow_nominal=1) ;
Buildings.Fluid.Sensors.RelativeHumidityTwoPort senRelHum(
redeclare package
Medium = Medium, m_flow_nominal=1) ;
Buildings.Fluid.Sensors.MassFractionTwoPort senMasFra(
redeclare package
Medium = Medium, m_flow_nominal=1) ;
equation
connect(weaDat.weaBus, bou.weaBus);
connect(senTem.port_b, sin.ports[1]);
connect(senRelHum.port_a, bou.ports[1]);
connect(senRelHum.port_b, senMasFra.port_a);
connect(senMasFra.port_b, senTem.port_a);
end Outside;
Test model for source and sink with outside weather data and wind pressure
Information
This model demonstrates the use of a source for ambient temperature, pressure and
species concentration.
The models bou1
and bou2
compute the ambient pressure
based on the weather file and the wind pressure.
The model bou1
uses a parameter for the wind pressure coefficient,
whereas bou2
uses the wind pressure coefficient from its input port.
The model bouFix
does not compute any wind pressure.
Adding the wind pressure to the models on the left-hand side induces a mass flow
rate through the orifice models ori1
and ori2
.
Since both source models use the same constant wind pressure coefficient, the
mass flow rate through the orifice model is the same.
In more realistic applications, the constant source Cp
would be
replaced by a model that computes a wind pressure coefficient that takes into
account the wind direction relative to the building.
Extends from Modelica.Icons.Example (Icon for runnable examples).
Modelica definition
model Outside_Cp
extends Modelica.Icons.Example;
package Medium =
Buildings.Media.Air ;
Buildings.Fluid.Sources.Outside_Cp bou1(
redeclare package Medium = Medium,
nPorts=1,
Cp=0.6) ;
Buildings.BoundaryConditions.WeatherData.ReaderTMY3 weaDat(filNam="modelica://Buildings/Resources/weatherdata/USA_CA_San.Francisco.Intl.AP.724940_TMY3.mos");
Buildings.Fluid.Sources.Outside bouFix(
redeclare package Medium = Medium,
nPorts=2) ;
Modelica.Blocks.Sources.Constant Cp(k=0.6) ;
Buildings.Airflow.Multizone.Orifice ori1(A=0.1,
redeclare package Medium = Medium)
;
Buildings.Fluid.Sources.Outside_Cp bou2(
redeclare package Medium = Medium,
nPorts=1,
use_Cp_in=true) ;
Buildings.Airflow.Multizone.Orifice ori2(A=0.1,
redeclare package Medium = Medium)
;
equation
connect(weaDat.weaBus, bou1.weaBus);
connect(bou1.ports[1], ori1.port_a);
connect(ori1.port_b, bouFix.ports[1]);
connect(weaDat.weaBus, bouFix.weaBus);
connect(bou2.Cp_in, Cp.y);
connect(bou2.ports[1], ori2.port_a);
connect(ori2.port_b, bouFix.ports[2]);
connect(weaDat.weaBus, bou2.weaBus);
end Outside_Cp;
Test model for source and sink with outside weather data and wind pressure
Information
This model demonstrates the use of a source for ambient conditions that computes
the wind pressure on a facade of a low-rise building.
Weather data are used for San Francisco, for a period of a week
where the wind blows primarily from North-West.
The plot shows that the wind pressure on the north- and west-facing
facade is positive,
whereas it is negative for the south- and east-facing facades.
Extends from Modelica.Icons.Example (Icon for runnable examples).
Modelica definition
model Outside_CpLowRise
extends Modelica.Icons.Example;
package Medium =
Buildings.Media.Air ;
Buildings.Fluid.Sources.Outside_CpLowRise west(
redeclare package Medium = Medium,
s=5,
azi=Buildings.Types.Azimuth.W,
Cp0=0.6) ;
Buildings.BoundaryConditions.WeatherData.ReaderTMY3 weaDat(filNam="modelica://Buildings/Resources/weatherdata/USA_CA_San.Francisco.Intl.AP.724940_TMY3.mos");
Buildings.Fluid.Sources.Outside_CpLowRise north(
redeclare package Medium = Medium,
s=1/5,
azi=Buildings.Types.Azimuth.N,
Cp0=0.6) ;
Buildings.Fluid.Sources.Outside_CpLowRise south(
redeclare package Medium = Medium,
s=1/5,
azi=Buildings.Types.Azimuth.S,
Cp0=0.6) ;
Buildings.Fluid.Sources.Outside_CpLowRise east(
redeclare package Medium = Medium,
s=5,
azi=Buildings.Types.Azimuth.E,
Cp0=0.6) ;
equation
connect(weaDat.weaBus, west.weaBus);
connect(weaDat.weaBus, north.weaBus);
connect(weaDat.weaBus, south.weaBus);
connect(weaDat.weaBus, east.weaBus);
end Outside_CpLowRise;
Information
This model demonstrates the use of trace substances that are added
to a volume of air.
The source is a step function of
2 kg/s CO
2 from
t=0 second
to
t=0.5 second.
The sensors
C
and
C1
measure the same concentration that initially increases
and then remains constant as there is no flow through the volumes
vol
and
vol1
.
The sensors
C2
and
C3
first meaure an increase in concentration, which then decays to zero
as there is a mass flow rate with zero CO
2 from the source
bou
to the sink
sin
.
Extends from Modelica.Icons.Example (Icon for runnable examples).
Modelica definition
model TraceSubstancesFlowSource
extends Modelica.Icons.Example;
package Medium =
Buildings.Media.Air (extraPropertiesNames={"CO2"});
MixingVolumes.MixingVolume vol(
redeclare package Medium = Medium,
V=100,
m_flow_nominal=1,
nPorts=3,
energyDynamics=Modelica.Fluid.Types.Dynamics.FixedInitial) ;
Sources.TraceSubstancesFlowSource sou(
redeclare package Medium = Medium,
use_m_flow_in=true,
nPorts=1);
Modelica.Blocks.Sources.Step step(
startTime=0.5,
height=-2,
offset=2);
FixedResistances.PressureDrop res(
redeclare package Medium = Medium,
m_flow_nominal=1,
dp_nominal=1) ;
MixingVolumes.MixingVolume vol1(
redeclare package Medium = Medium,
V=100,
m_flow_nominal=1,
nPorts=3,
energyDynamics=Modelica.Fluid.Types.Dynamics.FixedInitial) ;
Sources.TraceSubstancesFlowSource sou1(
redeclare package Medium = Medium,
use_m_flow_in=true,
nPorts=1);
Buildings.Utilities.Diagnostics.AssertEquality assEqu(threShold=1E-4) ;
MixingVolumes.MixingVolume vol2(
redeclare package Medium = Medium,
p_start=Medium.p_default,
V=100,
m_flow_nominal=1,
nPorts=3,
energyDynamics=Modelica.Fluid.Types.Dynamics.FixedInitial) ;
MixingVolumes.MixingVolume vol3(
redeclare package Medium = Medium,
p_start=Medium.p_default,
V=100,
m_flow_nominal=1,
nPorts=3,
energyDynamics=Modelica.Fluid.Types.Dynamics.FixedInitial) ;
Buildings.Utilities.Diagnostics.AssertEquality assEqu1(threShold=1E-4) ;
MixingVolumes.MixingVolume vol4(
redeclare package Medium = Medium,
nPorts=4,
p_start=Medium.p_default,
V=100,
m_flow_nominal=1,
energyDynamics=Modelica.Fluid.Types.Dynamics.FixedInitial) ;
Sources.TraceSubstancesFlowSource sou2(
redeclare package Medium = Medium,
use_m_flow_in=true,
nPorts=1);
Buildings.Fluid.Sources.Boundary_pT bou(
redeclare package Medium = Medium,
p=101325,
nPorts=1,
T=293.15);
Buildings.Fluid.Sources.Boundary_pT sin(
redeclare package Medium = Medium,
nPorts=2,
p=101320,
T=293.15) ;
FixedResistances.PressureDrop res1(
redeclare package Medium = Medium,
m_flow_nominal=1,
dp_nominal=1) ;
FixedResistances.PressureDrop res2(
redeclare package Medium = Medium,
m_flow_nominal=1,
dp_nominal=1) ;
FixedResistances.PressureDrop res3(
redeclare package Medium = Medium,
m_flow_nominal=1,
dp_nominal=1) ;
Sensors.TraceSubstances C(
redeclare package Medium = Medium) ;
Sensors.TraceSubstances C1(
redeclare package Medium = Medium) ;
Sensors.TraceSubstances C2(
redeclare package Medium = Medium) ;
Sensors.TraceSubstances C3(
redeclare package Medium = Medium) ;
FixedResistances.PressureDrop res4(
redeclare package Medium = Medium,
m_flow_nominal=1,
dp_nominal=1) ;
FixedResistances.PressureDrop res6(
redeclare package Medium = Medium,
m_flow_nominal=1,
dp_nominal=1) ;
FixedResistances.PressureDrop res5(
redeclare package Medium = Medium,
m_flow_nominal=1,
dp_nominal=1) ;
FixedResistances.PressureDrop res7(
redeclare package Medium = Medium,
m_flow_nominal=1,
dp_nominal=1) ;
Buildings.Fluid.Sources.Boundary_pT sin1(
redeclare package Medium = Medium,
nPorts=2,
p=101320,
T=293.15) ;
equation
connect(res3.port_b, vol4.ports[2]);
connect(res1.port_b, sin.ports[1]);
connect(res2.port_b, sin.ports[2]);
connect(bou.ports[1], res3.port_a);
connect(sou1.ports[1], res.port_a);
connect(sou2.ports[1], vol4.ports[1]);
connect(step.y, sou.m_flow_in);
connect(step.y, sou1.m_flow_in);
connect(step.y, sou2.m_flow_in);
connect(assEqu.u1, C.C);
connect(C1.C, assEqu.u2);
connect(assEqu1.u1, C2.C);
connect(C3.C, assEqu1.u2);
connect(sou.ports[1], vol.ports[1]);
connect(vol.ports[2], C.port);
connect(res.port_b, vol1.ports[1]);
connect(vol1.ports[2], C1.port);
connect(vol2.ports[1], res1.port_a);
connect(vol3.ports[1], res2.port_a);
connect(C2.port, vol2.ports[2]);
connect(C3.port, vol3.ports[2]);
connect(vol4.ports[3], res4.port_a);
connect(vol4.ports[4], res6.port_a);
connect(res6.port_b, vol3.ports[3]);
connect(res4.port_b, vol2.ports[3]);
connect(vol.ports[3], res5.port_a);
connect(res5.port_b, sin1.ports[1]);
connect(vol1.ports[3], res7.port_a);
connect(res7.port_b, sin1.ports[2]);
end TraceSubstancesFlowSource;