LBL logo

Buildings.Electrical.AC.OnePhase.Sensors.Examples

Package with example models

Information

This package contains examples for the use of models that can be found in Buildings.Electrical.AC.OnePhase.Sensors.

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

Name Description
Buildings.Electrical.AC.OnePhase.Sensors.Examples.GeneralizedSensor GeneralizedSensor This example illustrates how to use the generalized sensor model
Buildings.Electrical.AC.OnePhase.Sensors.Examples.Probe Probe This example illustrates how to use the probe model

Buildings.Electrical.AC.OnePhase.Sensors.Examples.GeneralizedSensor Buildings.Electrical.AC.OnePhase.Sensors.Examples.GeneralizedSensor

This example illustrates how to use the generalized sensor model

Buildings.Electrical.AC.OnePhase.Sensors.Examples.GeneralizedSensor

Information

This example illustrates the use of the generalized sensor.

Extends from Modelica.Icons.Example (Icon for runnable examples).

Modelica definition

model GeneralizedSensor "This example illustrates how to use the generalized sensor model" extends Modelica.Icons.Example; Buildings.Electrical.AC.OnePhase.Sensors.GeneralizedSensor sen "Sensor that measures V, I, and S"; Buildings.Electrical.AC.OnePhase.Loads.Capacitive loa( mode=Buildings.Electrical.Types.Load.FixedZ_dynamic, P_nominal=-100, V_nominal=120) "Constant load"; Buildings.Electrical.AC.OnePhase.Sources.FixedVoltage sou(f=60, V=120) "Voltage source"; Buildings.Electrical.AC.OnePhase.Lines.TwoPortResistance res(R=0.05) "Line resistance"; equation connect(sen.terminal_p, loa.terminal); connect(sou.terminal, res.terminal_n); connect(res.terminal_p, sen.terminal_n); end GeneralizedSensor;

Buildings.Electrical.AC.OnePhase.Sensors.Examples.Probe Buildings.Electrical.AC.OnePhase.Sensors.Examples.Probe

This example illustrates how to use the probe model

Buildings.Electrical.AC.OnePhase.Sensors.Examples.Probe

Information

This example illustrates the use of the probe model.

Extends from Modelica.Icons.Example (Icon for runnable examples).

Modelica definition

model Probe "This example illustrates how to use the probe model" extends Modelica.Icons.Example; Buildings.Electrical.AC.OnePhase.Loads.Capacitive loaRC( mode=Buildings.Electrical.Types.Load.FixedZ_steady_state, P_nominal=-10000, V_nominal=120) "Constant load"; Buildings.Electrical.AC.OnePhase.Sources.FixedVoltage sou(f=60, V=120) "Voltage source"; Buildings.Electrical.AC.OnePhase.Lines.TwoPortResistance res1(R=0.1) "First line resistance"; Buildings.Electrical.AC.OnePhase.Sensors.Probe probe_source(V_nominal=120) "Probe that measures at the voltage source"; Buildings.Electrical.AC.OnePhase.Sensors.Probe probe_loadRC(V_nominal=120) "Probe that measures at the RC load"; Buildings.Electrical.AC.OnePhase.Lines.TwoPortResistance res2(R=0.1) "Second line resistance"; Buildings.Electrical.AC.OnePhase.Loads.Inductive loaRL( mode=Buildings.Electrical.Types.Load.FixedZ_steady_state, P_nominal=-10000, V_nominal=120) "Constant load"; Buildings.Electrical.AC.OnePhase.Sensors.Probe probe_loadRL(V_nominal=120) "Probe that measures at the RL load"; equation connect(sou.terminal, res1.terminal_n); connect(res1.terminal_p, loaRC.terminal); connect(sou.terminal, probe_source.term); connect(loaRC.terminal, probe_loadRC.term); connect(sou.terminal, res2.terminal_n); connect(res2.terminal_p, loaRL.terminal); connect(loaRL.terminal, probe_loadRL.term); end Probe;

http://simulationresearch.lbl.gov/modelica