Package with performance data for solar thermal collectors. All solar collector data package names begin with an abbreviation of the type of collector it is. The abbreviations are as follows:
| Name | Description |
|---|---|
| Package with SRCC rating information for concentrating solar thermal collectors | |
| Package with SRCC rating information for glazed flat-plate solar thermal collectors | |
| Package with SRCC rating information for tubular solar thermal collectors | |
| Generic data record providing inputs for specific collector data records |
Generic data file which is used for the Buildings.Fluid.Solarcollectors.BaseClasses.PartialSolarCollector model. Establishes the base inputs needed to create model-specific data packages.
| Type | Name | Default | Description |
|---|---|---|---|
| Area | ATyp | Gross or aperture area | |
| Area | A | Area [m2] | |
| Mass | mDry | Dry weight [kg] | |
| Volume | V | Fluid volume [m3] | |
| Pressure | dp_nominal | Pressure drop during test conditions [Pa] | |
| Real | mperA_flow_nominal | Mass flow rate per unit area of collector [kg/(s.m2)] | |
| Real | B0 | 1st incident angle modifier coefficient | |
| Real | B1 | 2nd incident angle modifier coefficient | |
| Real | y_intercept | Y intercept (Maximum efficiency) | |
| Real | slope | Slope from rating data [W/(m2.K)] | |
| Real | IAMDiff | Incidence angle modifier from EN12975 ratings data | |
| Real | C1 | Heat loss coefficient from EN12975 ratings data | |
| Real | C2 | Temperature dependence of heat loss from EN12975 ratings data | |
| Irradiance | G_nominal | Nominal solar irradiance specified in ratings data [W/m2] | |
| TemperatureDifference | dT_nominal | Nominal temperature difference specified in ratings data [K] |
record GenericSolarCollector
"Generic data record providing inputs for specific collector data records"
parameter SolarCollectors.Types.Area ATyp "Gross or aperture area";
parameter Modelica.SIunits.Area A "Area";
parameter Modelica.SIunits.Mass mDry "Dry weight";
parameter Modelica.SIunits.Volume V "Fluid volume";
parameter Modelica.SIunits.Pressure dp_nominal
"Pressure drop during test conditions";
parameter Real mperA_flow_nominal(unit="kg/(s.m2)")
"Mass flow rate per unit area of collector";
parameter Real B0 "1st incident angle modifier coefficient";
parameter Real B1 "2nd incident angle modifier coefficient";
parameter Real y_intercept "Y intercept (Maximum efficiency)";
parameter Real slope(unit = "W/(m2.K)") "Slope from rating data";
parameter Real IAMDiff "Incidence angle modifier from EN12975 ratings data";
parameter Real C1 "Heat loss coefficient from EN12975 ratings data";
parameter Real C2
"Temperature dependence of heat loss from EN12975 ratings data";
parameter Modelica.SIunits.Irradiance G_nominal
"Nominal solar irradiance specified in ratings data";
parameter Modelica.SIunits.TemperatureDifference dT_nominal
"Nominal temperature difference specified in ratings data";
end GenericSolarCollector;