This package contains examples for the use of models that can be found in Buildings.Fluid.FixedResistances.
Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).
Name | Description |
---|---|
FixedResistance | |
FixedResistancesExplicit | Test of multiple resistances in series |
FixedResistancesParallel | |
FixedResistancesSeries | Test of multiple resistances in series |
SplitterFixedResistanceDpM | |
Pipe | Test of a pipe with multiple segments |
model FixedResistance import Buildings; extends Modelica.Icons.Example; package Medium = Buildings.Media.ConstantPropertyLiquidWater;Modelica.Blocks.Sources.Constant PAtm(k=101325); Modelica.Blocks.Sources.Ramp P( duration=1, height=20, offset=101315); Buildings.Fluid.FixedResistances.FixedResistanceDpM res1( redeclare package Medium = Medium, from_dp=true, m_flow_nominal=5, dp_nominal=10); Buildings.Fluid.Sources.Boundary_pT sou1( redeclare package Medium = Medium, use_p_in=true, T=293.15, nPorts=3); Buildings.Fluid.Sources.Boundary_pT sin1( redeclare package Medium = Medium, T=283.15, use_p_in=true, nPorts=3); Buildings.Fluid.FixedResistances.FixedResistanceDpM res2( redeclare package Medium = Medium, from_dp=true, m_flow_nominal=5, dp_nominal=10, use_dh=true); Buildings.Fluid.FixedResistances.FixedResistanceDpM res3( redeclare package Medium = Medium, from_dp=true, m_flow_nominal=5, dp_nominal=10, use_dh=true); FixedResistances.LosslessPipe pipCon(redeclare package Medium = Medium, m_flow_nominal=5) "Lossless pipe connection"; Buildings.Fluid.Sensors.MassFlowRate masFlo2(redeclare package Medium = Medium) "Mass flow rate sensor"; Buildings.Fluid.Sensors.MassFlowRate masFlo3(redeclare package Medium = Medium) "Mass flow rate sensor"; Buildings.Utilities.Diagnostics.AssertEquality assEqu(threShold=1E-4, message= "Inputs differ, check that lossless pipe is correctly implemented.") "Assert equality of the two mass flow rates"; inner Modelica.Fluid.System system; equationconnect(res2.port_b, masFlo2.port_a); connect(res3.port_b, masFlo3.port_a); connect(masFlo3.port_b, pipCon.port_a); connect(P.y, sou1.p_in); connect(sou1.ports[1], res1.port_a); connect(sin1.ports[1], res1.port_b); connect(masFlo3.m_flow, assEqu.u1); connect(masFlo2.m_flow, assEqu.u2); connect(PAtm.y, sin1.p_in); connect(sou1.ports[2], res2.port_a); connect(sou1.ports[3], res3.port_a); connect(sin1.ports[2], masFlo2.port_b); connect(sin1.ports[3], pipCon.port_b); end FixedResistance;
Extends from Modelica.Icons.Example (Icon for runnable examples).
model FixedResistancesExplicit "Test of multiple resistances in series" import Buildings; extends Modelica.Icons.Example; package Medium = Buildings.Media.IdealGases.SimpleAir;Buildings.Fluid.Sources.Boundary_ph sou( redeclare package Medium = Medium, nPorts=1, p(displayUnit="Pa") = 101335, use_p_in=true); Buildings.Fluid.Sources.Boundary_ph sin( redeclare package Medium = Medium, nPorts=1, use_p_in=false, p=101325); Buildings.Fluid.FixedResistances.FixedResistanceDpM res11( redeclare package Medium = Medium, from_dp=false, m_flow_nominal=2, dp_nominal=5); inner Modelica.Fluid.System system(p_ambient=101325); Buildings.Fluid.FixedResistances.FixedResistanceDpM res12( redeclare package Medium = Medium, from_dp=false, m_flow_nominal=2, dp_nominal=5); Buildings.Fluid.FixedResistances.FixedResistanceDpM res22( redeclare package Medium = Medium, m_flow_nominal=2, dp_nominal=5, from_dp=true); Buildings.Fluid.FixedResistances.FixedResistanceDpM res21( redeclare package Medium = Medium, m_flow_nominal=2, dp_nominal=5, from_dp=true); Buildings.Fluid.FixedResistances.FixedResistanceDpM res31( redeclare package Medium = Medium, from_dp=false, m_flow_nominal=2, dp_nominal=5); Buildings.Fluid.FixedResistances.FixedResistanceDpM res32( redeclare package Medium = Medium, from_dp=false, m_flow_nominal=2, dp_nominal=5); Buildings.Fluid.FixedResistances.FixedResistanceDpM res42( redeclare package Medium = Medium, m_flow_nominal=2, dp_nominal=5, from_dp=true); Buildings.Fluid.FixedResistances.FixedResistanceDpM res41( redeclare package Medium = Medium, m_flow_nominal=2, dp_nominal=5, from_dp=true); Buildings.Fluid.Sources.MassFlowSource_h bou( redeclare package Medium = Medium, m_flow=1, nPorts=1); Buildings.Fluid.Sources.MassFlowSource_h bou1( redeclare package Medium = Medium, m_flow=1, nPorts=1); Buildings.Fluid.Sources.Boundary_pT sin1( redeclare package Medium = Medium, T=273.15 + 10, nPorts=2, use_p_in=false, p=101325); Buildings.Fluid.Sources.Boundary_ph sin2( redeclare package Medium = Medium, nPorts=1, use_p_in=false, p=101325); Buildings.Fluid.Sources.Boundary_ph sou1( redeclare package Medium = Medium, nPorts=1, p(displayUnit="Pa") = 101335, use_p_in=true); Modelica.Blocks.Sources.Ramp P( duration=1, height=20, offset=101315); Buildings.Fluid.Sensors.MassFlowRate senMasFlo1(redeclare package Medium = Medium) "Mass flow rate sensor"; Buildings.Fluid.Sensors.MassFlowRate senMasFlo2(redeclare package Medium = Medium) "Mass flow rate sensor"; Buildings.Fluid.Sensors.MassFlowRate senMasFlo3(redeclare package Medium = Medium) "Mass flow rate sensor"; Buildings.Fluid.Sensors.MassFlowRate senMasFlo4(redeclare package Medium = Medium) "Mass flow rate sensor"; Buildings.Utilities.Diagnostics.AssertEquality assertEquality; Buildings.Utilities.Diagnostics.AssertEquality assertEquality1; equationconnect(res11.port_b, res12.port_a); connect(res21.port_b, res22.port_a); connect(res31.port_b, res32.port_a); connect(res41.port_b, res42.port_a); connect(sou.ports[1], res11.port_a); connect(bou.ports[1], res31.port_a); connect(bou1.ports[1], res41.port_a); connect(sou1.ports[1], res21.port_a); connect(P.y, sou.p_in); connect(P.y, sou1.p_in); connect(res12.port_b, senMasFlo1.port_a); connect(res22.port_b, senMasFlo2.port_a); connect(res32.port_b, senMasFlo3.port_a); connect(res42.port_b, senMasFlo4.port_a); connect(senMasFlo3.port_b, sin1.ports[1]); connect(senMasFlo4.port_b, sin1.ports[2]); connect(senMasFlo1.port_b, sin.ports[1]); connect(senMasFlo2.port_b, sin2.ports[1]); connect(senMasFlo3.m_flow, assertEquality1.u1); connect(senMasFlo4.m_flow, assertEquality1.u2); connect(senMasFlo1.m_flow, assertEquality.u1); connect(senMasFlo2.m_flow, assertEquality.u2); end FixedResistancesExplicit;
model FixedResistancesParallel import Buildings; extends Modelica.Icons.Example; package Medium = Buildings.Media.ConstantPropertyLiquidWater;Modelica.Blocks.Sources.Constant PAtm(k=101325); Modelica.Blocks.Sources.Ramp P( duration=1, height=20, offset=101315); Buildings.Fluid.FixedResistances.FixedResistanceDpM res1( redeclare package Medium = Medium, m_flow_nominal=5, dp_nominal=10, deltaM=0.3, linearized=false, from_dp=false); Buildings.Fluid.Sources.Boundary_pT sou1( redeclare package Medium = Medium, T=293.15, nPorts=2, use_p_in=true); Buildings.Fluid.Sources.Boundary_pT sin1( redeclare package Medium = Medium, T=283.15, nPorts=2, use_p_in=true); Buildings.Fluid.FixedResistances.FixedResistanceDpM res2( redeclare package Medium = Medium, m_flow_nominal=5, dp_nominal=10, deltaM=0.3, linearized=false, from_dp=false); Buildings.Fluid.Sensors.MassFlowRate masFlo2(redeclare package Medium = Medium) "Mass flow rate sensor"; Buildings.Utilities.Diagnostics.AssertEquality assEqu(threShold=1E-4, message= "Inputs differ, check that lossless pipe is correctly implemented.") "Assert equality of the two mass flow rates"; Buildings.Fluid.Sensors.MassFlowRate masFlo1(redeclare package Medium = Medium) "Mass flow rate sensor"; inner Modelica.Fluid.System system(p_ambient=101325); equationconnect(PAtm.y, sin1.p_in); connect(P.y, sou1.p_in); connect(res2.port_b, masFlo2.port_a); connect(res1.port_b, masFlo1.port_a); connect(sou1.ports[1], res1.port_a); connect(sou1.ports[2], res2.port_a); connect(sin1.ports[1], masFlo1.port_b); connect(sin1.ports[2], masFlo2.port_b); connect(masFlo2.m_flow, assEqu.u1); connect(masFlo1.m_flow, assEqu.u2); end FixedResistancesParallel;
Type | Name | Default | Description |
---|---|---|---|
Pressure | dp_nominal | 5 | Nominal pressure drop for each resistance [Pa] |
Integer | nRes | 10 | Number of resistances |
model FixedResistancesSeries "Test of multiple resistances in series" extends Modelica.Icons.Example; package Medium = Buildings.Media.IdealGases.SimpleAir;Modelica.Blocks.Sources.Constant PAtm(k=101325); parameter Modelica.SIunits.Pressure dp_nominal = 5 "Nominal pressure drop for each resistance";Modelica.Blocks.Sources.Ramp P( duration=1, height=2*dp_nominal*nRes, offset=101325 - dp_nominal*nRes); Buildings.Fluid.Sources.Boundary_pT sou( redeclare package Medium = Medium, T=273.15 + 20, use_p_in=true, nPorts=1); Buildings.Fluid.Sources.Boundary_pT sin( redeclare package Medium = Medium, T=273.15 + 10, use_p_in=true, nPorts=1); parameter Integer nRes( min=2) = 10 "Number of resistances";Buildings.Fluid.FixedResistances.FixedResistanceDpM[ nRes] res( redeclare each package Medium = Medium, each dp_nominal=dp_nominal, each from_dp = false, each m_flow_nominal=2); inner Modelica.Fluid.System system(p_ambient=101325); equation for i in 1:nRes-1 loopconnect(res[i].port_b, res[i+1].port_a); end for;connect(PAtm.y, sin.p_in); connect(P.y, sou.p_in); connect(sin.ports[1], res[nRes].port_b); connect(sou.ports[1], res[1].port_a); end FixedResistancesSeries;
model SplitterFixedResistanceDpM extends Modelica.Icons.Example; package Medium = Buildings.Media.IdealGases.SimpleAir;Buildings.Fluid.FixedResistances.SplitterFixedResistanceDpM spl( m_flow_nominal={1,2,3}, dh={1,2,3}, redeclare package Medium = Medium, dp_nominal(displayUnit="Pa") = {5,10,15}) "Splitter"; Buildings.Fluid.Sources.Boundary_pT bou1( redeclare package Medium = Medium, T=273.15 + 10, use_p_in=true, nPorts=1); Buildings.Fluid.Sources.Boundary_pT bou2( redeclare package Medium = Medium, T=273.15 + 20, use_p_in=true, nPorts=1); Buildings.Fluid.Sources.Boundary_pT bou3( redeclare package Medium = Medium, T=273.15 + 30, use_p_in=true, nPorts=1); Modelica.Blocks.Sources.Constant P2(k=101325); Modelica.Blocks.Sources.Ramp P1( offset=101320, height=10, duration=0.5); Modelica.Blocks.Sources.Ramp P3( offset=101320, height=10, duration=0.5, startTime=0.5); inner Modelica.Fluid.System system(p_ambient=101325); equationconnect(P1.y, bou1.p_in); connect(P2.y, bou2.p_in); connect(bou3.p_in, P3.y); connect(bou1.ports[1], spl.port_1); connect(bou3.ports[1], spl.port_3); connect(spl.port_2, bou2.ports[1]); end SplitterFixedResistanceDpM;
This model demonstrates the use of a pipe model.
Both pipe models have the same mass flow rates and temperatures.
Otherwise, the assert
block would terminate the simulation.
The model on the top is connected to the ambient with one heat port, whereas the model at the bottom uses a vector of heat ports. Since they are all connected to the same temperature, they result in the same energy balance for the medium that flows through the pipe.
Extends from Modelica.Icons.Example (Icon for runnable examples).
Type | Name | Default | Description |
---|---|---|---|
replaceable package Medium | Buildings.Media.ConstantProp... |
Type | Name | Description |
---|---|---|
replaceable package Medium |
model Pipe "Test of a pipe with multiple segments" import Buildings; extends Modelica.Icons.Example; replaceable package Medium = Buildings.Media.ConstantPropertyLiquidWater;Modelica.Blocks.Sources.Ramp P( duration=1, height=2*pip.dp_nominal, offset=101325 - pip.dp_nominal); Buildings.Fluid.Sources.Boundary_pT sou( redeclare package Medium = Medium, use_p_in=true, T=273.15 + 50, nPorts=2); Buildings.Fluid.Sources.Boundary_pT sin( redeclare package Medium = Medium, T=273.15 + 10, nPorts=2, use_p_in=false, p(displayUnit="Pa") = 101325); inner Modelica.Fluid.System system(p_ambient=101325); HeatTransfer.Sources.FixedTemperature TEnv(T=263.15); Buildings.Fluid.FixedResistances.Pipe pip( thicknessIns=0.01, lambdaIns=0.01, m_flow_nominal=10, redeclare package Medium = Medium, length=10); HeatTransfer.Sources.FixedTemperature TEnv1[10](each T=263.15); Buildings.Fluid.FixedResistances.Pipe pip1( thicknessIns=0.01, lambdaIns=0.01, m_flow_nominal=10, redeclare package Medium = Medium, length=10, useMultipleHeatPorts=true); Buildings.Fluid.Sensors.TemperatureTwoPort senTem(redeclare package Medium = Medium, m_flow_nominal=pip.m_flow_nominal) "Temperature sensor"; Buildings.Fluid.Sensors.TemperatureTwoPort senTem1(redeclare package Medium = Medium, m_flow_nominal=pip.m_flow_nominal) "Temperature sensor"; Buildings.Utilities.Diagnostics.AssertEquality assEqu; equationconnect(P.y, sou.p_in); connect(sou.ports[1], pip.port_a); connect(TEnv.port, pip.heatPort); connect(sou.ports[2], pip1.port_a); connect(TEnv1.port, pip1.heatPorts); connect(pip.port_b, senTem.port_a); connect(senTem.port_b, sin.ports[1]); connect(pip1.port_b, senTem1.port_a); connect(senTem1.port_b, sin.ports[2]); connect(assEqu.u1, senTem.T); connect(senTem1.T, assEqu.u2); end Pipe;