Name | Description |
p | Number of pole pairs (Integer) |
fsNominal | Nominal frequency [Hz] |
useSupport | Enable / disable (=fixed stator) support |
Js | Stator's moment of inertia [kg.m2] |
useThermalPort | Enable / disable (=fixed temperatures) thermal port |
powerBalance | Power balance |
thermalPort | |
thermalAmbient | |
Operational temperatures |
TsOperational | Operational temperature of stator resistance [K] |
Initialization |
phiMechanical | Mechanical angle of rotor against stator [rad] |
wMechanical | Mechanical angular velocity of rotor against stator [rad/s] |
Nominal resistances and inductances |
Rs | Stator resistance per phase at TRef [Ohm] |
TsRef | Reference temperature of stator resistance [K] |
alpha20s | Temperature coefficient of stator resistance at 20 degC [1/K] |
Lszero | Stator zero sequence inductance [H] |
Lssigma | Stator stray inductance [H] |
Losses |
statorCoreParameters | Stator core losses; all parameters refer to stator side |
strayLoadParameters | Stray load losses |
Name | Description |
useSupport | Enable / disable (=fixed stator) support |
Js | Stator's moment of inertia [kg.m2] |
useThermalPort | Enable / disable (=fixed temperatures) thermal port |
powerBalance | Power balance |
thermalPort | |
thermalAmbient | |
Operational temperatures |
TaOperational | Operational armature temperature [K] |
Initialization |
phiMechanical | Mechanical angle of rotor against stator [rad] |
wMechanical | Mechanical angular velocity of rotor against stator [rad/s] |
Nominal parameters |
VaNominal | Nominal armature voltage [V] |
IaNominal | Nominal armature current (>0..Motor, <0..Generator) [A] |
wNominal | Nominal speed [rad/s] |
TaNominal | Nominal armature temperature [K] |
Nominal resistances and inductances |
Ra | Armature resistance at TRef [Ohm] |
TaRef | Reference temperature of armature resistance [K] |
alpha20a | Temperature coefficient of armature resistance [1/K] |
La | Armature inductance [H] |
Losses |
coreParameters | Armature core losses |
strayLoadParameters | Stray load losses |
brushParameters | Brush losses |
turns ratio n |
1 | |
nominal frequency fNominal |
50 | Hz |
nominal voltage per phase |
100 | V RMS |
nominal current per phase |
100 | A RMS |
nominal apparent power |
30 | kVA |
primary resistance R1 |
0.005 | Ohm per phase at reference temperature |
reference temperature T1Ref |
20 | °C |
temperature coefficient alpha20_1 |
0 | 1/K |
primary stray inductance L1sigma |
78E-6 | H per phase |
secondary resistance R2 |
0.005 | Ohm per phase at reference temperature |
reference temperature T2Ref |
20 | °C |
temperature coefficient alpha20_2 |
0 | 1/K |
secondary stray inductance L2sigma |
78E-6 | H per phase |
operational temperature T1Operational |
20 | °C |
operational temperature T2Operational |
20 | °C |
These values give the operational parameters: |
| |
nominal voltage drop |
0.05 | p.u. |
nominal copper losses |
300 | W |
Name | Description |
n | Ratio primary voltage (line-to-line) / secondary voltage (line-to-line) |
useThermalPort | Enable / disable (=fixed temperatures) thermal port |
Operational temperatures |
T1Operational | Operational temperature of primary resistance [K] |
T2Operational | Operational temperature of secondary resistance [K] |
Nominal resistances and inductances |
R1 | Primary resistance per phase at TRef [Ohm] |
T1Ref | Reference temperature of primary resistance [K] |
alpha20_1 | Temperature coefficient of primary resistance at 20 degC [1/K] |
L1sigma | Primary stray inductance per phase [H] |
R2 | Secondary resistance per phase at TRef [Ohm] |
T2Ref | Reference temperature of secondary resistance [K] |
alpha20_2 | Temperature coefficient of secondary resistance at 20 degC [1/K] |
L2sigma | Secondary stray inductance per phase [H] |
This partial model defines shaft and housing connector for loss models.
Positive torque tau