Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel
Validation for conditional constructions but with sampled models
Information
The models in this package are identical to the models in
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions
except that the models set the parameter
sampleModel = true
in order to verify that all initial equations are specified.
Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).
Package Content
| Name | Description | 
|---|---|
|  OnlyConstructionBoundary | Test model with sampleModel = true | 
|  OnlyExteriorWallNoWindow | Test model with sampleModel = true | 
|  OnlyExteriorWallWithWindow | Test model with sampleModel = true | 
|  OnlyExteriorWallWithWindowExteriorShade | Test model with sampleModel = true | 
|  OnlyExteriorWallWithWindowInteriorShade | Test model with sampleModel = true | 
|  OnlyPartition | Test model with sampleModel = true | 
|  OnlySurfaceBoundary | Test model with sampleModel = true | 
 Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyConstructionBoundary
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyConstructionBoundary
Test model with sampleModel = true
 
Information
This model is identical to
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyConstructionBoundary,
except that it sets sampleModel=true.
Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyConstructionBoundary (Test model for room model).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| Integer | nConExt | 0 | Number of exterior constructions that do not have a window | 
| Integer | nConExtWin | 0 | Number of exterior constructions that do have a window | 
| Integer | nConPar | 0 | Number of partition constructions | 
| Integer | nConBou | 1 | Number of surface that are connected to constructions that are modeled inside the room | 
| Integer | nSurBou | 0 | Number of surface that are connected to the room air volume | 
| Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
| Brick120 | matLayPar | Construction material for partition walls | |
| DoubleClearAir13Clear | glaSys | Data record for the glazing system | 
Modelica definition
 Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow
Test model with sampleModel = true
 
Information
This model is identical to
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow,
except that it sets sampleModel=true.
Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow (Test model for room model).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| Integer | nConExt | 1 | Number of exterior constructions that do not have a window | 
| Integer | nConExtWin | 0 | Number of exterior constructions that do have a window | 
| Integer | nConPar | 0 | Number of partition constructions | 
| Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room | 
| Integer | nSurBou | 0 | Number of surface that are connected to the room air volume | 
| Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
| Brick120 | matLayPar | Construction material for partition walls | |
| DoubleClearAir13Clear | glaSys | Data record for the glazing system | 
Modelica definition
 Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindow
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindow
Test model with sampleModel = true
 
Information
This model is identical to
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow,
except that it sets sampleModel=true.
Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow (Test model for room model).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| Integer | nConExt | 0 | Number of exterior constructions that do not have a window | 
| Integer | nConExtWin | 2 | Number of exterior constructions that do have a window | 
| Integer | nConPar | 0 | Number of partition constructions | 
| Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room | 
| Integer | nSurBou | 0 | Number of surface that are connected to the room air volume | 
| Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
| Brick120 | matLayPar | Construction material for partition walls | |
| DoubleClearAir13Clear | glaSys | Data record for the glazing system | 
Modelica definition
 Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowExteriorShade
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowExteriorShade
Test model with sampleModel = true
 
Information
This model is identical to
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowExteriorShade,
except that it sets sampleModel=true.
Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowExteriorShade (Test model for room model).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| Integer | nConExt | 0 | Number of exterior constructions that do not have a window | 
| Integer | nConExtWin | 2 | Number of exterior constructions that do have a window | 
| Integer | nConPar | 0 | Number of partition constructions | 
| Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room | 
| Integer | nSurBou | 0 | Number of surface that are connected to the room air volume | 
| Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
| Brick120 | matLayPar | Construction material for partition walls | |
| DoubleClearAir13Clear | glaSys | glaSys(haveExteriorShade=true) | Data record for the glazing system | 
Modelica definition
 Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade
Test model with sampleModel = true
 
Information
This model is identical to
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade,
except that it sets sampleModel=true.
Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade (Test model for room model).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| Integer | nConExt | 0 | Number of exterior constructions that do not have a window | 
| Integer | nConExtWin | 2 | Number of exterior constructions that do have a window | 
| Integer | nConPar | 0 | Number of partition constructions | 
| Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room | 
| Integer | nSurBou | 0 | Number of surface that are connected to the room air volume | 
| Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
| Brick120 | matLayPar | Construction material for partition walls | |
| DoubleClearAir13Clear | glaSys | glaSys(haveInteriorShade=true) | Data record for the glazing system | 
Modelica definition
 Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition
Test model with sampleModel = true
 
Information
This model is identical to
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition,
except that it sets sampleModel=true.
Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition (Test model for room model).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| Integer | nConExt | 0 | Number of exterior constructions that do not have a window | 
| Integer | nConExtWin | 0 | Number of exterior constructions that do have a window | 
| Integer | nConPar | 1 | Number of partition constructions | 
| Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room | 
| Integer | nSurBou | 0 | Number of surface that are connected to the room air volume | 
| Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
| Brick120 | matLayPar | Construction material for partition walls | |
| DoubleClearAir13Clear | glaSys | Data record for the glazing system | 
Modelica definition
 Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlySurfaceBoundary
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlySurfaceBoundary
Test model with sampleModel = true
 
Information
This model is identical to
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary,
except that it sets sampleModel=true.
Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary (Test model for room model).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| Integer | nConExt | 0 | Number of exterior constructions that do not have a window | 
| Integer | nConExtWin | 0 | Number of exterior constructions that do have a window | 
| Integer | nConPar | 0 | Number of partition constructions | 
| Integer | nConBou | 0 | Number of surface that are connected to constructions that are modeled inside the room | 
| Integer | nSurBou | 1 | Number of surface that are connected to the room air volume | 
| Insulation100Concrete200 | matLayExt | Construction material for exterior walls | |
| Brick120 | matLayPar | Construction material for partition walls | |
| DoubleClearAir13Clear | glaSys | Data record for the glazing system | 
