Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions

Constructions used in partitions contained within a test cell

Information

This package contains models of uninsulated partition walls used in the LBNL FLEXLAB facility.

Extends from Modelica.Icons.MaterialPropertiesPackage (Icon for package containing property classes).

Package Content

Name Description
Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions.PartitionDoor PartitionDoor Model of a partition door. Air is neglected
Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions.PartitionWall PartitionWall Model of a partition wall. Air is neglected

Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions.PartitionDoor Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions.PartitionDoor

Model of a partition door. Air is neglected

Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions.PartitionDoor

Information

This is a model of a parition door. It is used in every test cell as the door between the cell itself and the closet.

Extends from Buildings.HeatTransfer.Data.OpaqueConstructions.Generic (Thermal properties of opaque constructions).

Parameters

TypeNameDefaultDescription
IntegernLay2Number of layers
Materialmaterial[nLay]{Buildings.HeatTransfer.Data...Layer by layer declaration of material, starting from outside to room-side
EmissivityabsIR_a0.9Infrared absorptivity of surface a (usually outside-facing surface) [1]
EmissivityabsIR_b0.9Infrared absorptivity of surface b (usually room-facing surface) [1]
EmissivityabsSol_a0.5Solar absorptivity of surface a (usually outside-facing surface) [1]
EmissivityabsSol_b0.5Solar absorptivity of surface b (usually room-facing surface) [1]
SurfaceRoughnessroughness_aBuildings.HeatTransfer.Types...Exterior surface roughness

Modelica definition

record PartitionDoor = Buildings.HeatTransfer.Data.OpaqueConstructions.Generic(final material={ Buildings.HeatTransfer.Data.Solids.Plywood(x=0.01588), Buildings.HeatTransfer.Data.Solids.Plywood(x=0.01588)}, final nLay=2) "Model of a partition door. Air is neglected";

Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions.PartitionWall Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions.PartitionWall

Model of a partition wall. Air is neglected

Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions.PartitionWall

Information

This is a model of a partition wall. It is used in every test cell to separate the test cell itself and the attached closet.

Extends from Buildings.HeatTransfer.Data.OpaqueConstructions.Generic (Thermal properties of opaque constructions).

Parameters

TypeNameDefaultDescription
IntegernLay2Number of layers
Materialmaterial[nLay]{Buildings.HeatTransfer.Data...Layer by layer declaration of material, starting from outside to room-side
EmissivityabsIR_a0.9Infrared absorptivity of surface a (usually outside-facing surface) [1]
EmissivityabsIR_b0.9Infrared absorptivity of surface b (usually room-facing surface) [1]
EmissivityabsSol_a0.5Solar absorptivity of surface a (usually outside-facing surface) [1]
EmissivityabsSol_b0.5Solar absorptivity of surface b (usually room-facing surface) [1]
SurfaceRoughnessroughness_aBuildings.HeatTransfer.Types...Exterior surface roughness

Modelica definition

record PartitionWall = Buildings.HeatTransfer.Data.OpaqueConstructions.Generic(final material={ Buildings.HeatTransfer.Data.Solids.GypsumBoard(x=0.01588), Buildings.HeatTransfer.Data.Solids.GypsumBoard(x=0.01588)}, final nLay=2) "Model of a partition wall. Air is neglected";