Buildings.Fluid.Boilers.Data.Lochinvar.FTXL
Package with performance data for Lochinvar FTXL™ Fire Tube boilers
Information
This package contains performance data for Lochinvar FTXL™ Fire Tube boilers. See the documentation of Buildings.Fluid.Boilers.Data.Lochinvar.
Extends from Modelica.Icons.Package (Icon for standard packages).
Package Content
| Name | Description |
|---|---|
| Specifications for Lochinvar FTXL FTX400 boiler | |
| Specifications for Lochinvar FTXL FTX500 boiler | |
| Specifications for Lochinvar FTXL FTX600 boiler | |
| Specifications for Lochinvar FTXL FTX725 boiler | |
| Specifications for Lochinvar FTXL FTX850 boiler |
Buildings.Fluid.Boilers.Data.Lochinvar.FTXL.FTX400
Specifications for Lochinvar FTXL FTX400 boiler
Information
Performance data for boiler model. See the documentation of Buildings.Fluid.Boilers.Data.Lochinvar.
Extends from Buildings.Fluid.Boilers.Data.Generic (Generic data record for boiler performance).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | effCur[:, :] | [0, 294.264548954895, 299.82... | Efficiency curves as a table: First row = inlet temp(K), First column = firing rates or PLR |
| Temperature | TIn_nominal | 323.15 | Nominal inlet temperature for efficiency calculations [K] |
| Generic | fue | Buildings.Fluid.Data.Fuels.N... | Fuel type |
| Power | Q_flow_nominal | 114883.8594 | Nominal heating power [W] |
| ThermalConductance | UA | 0.05*Q_flow_nominal/30 | Overall UA value [W/K] |
| Volume | VWat | 0.049210353 | Water volume of boiler [m3] |
| Mass | mDry | 216.8171529 | Mass of boiler that will be lumped to water heat capacity [kg] |
| MassFlowRate | m_flow_nominal | 2.460518 | Nominal mass flow rate [kg/s] |
| PressureDifference | dp_nominal | 10461.43 | Pressure drop at m_flow_nominal [Pa] |
Modelica definition
Buildings.Fluid.Boilers.Data.Lochinvar.FTXL.FTX500
Specifications for Lochinvar FTXL FTX500 boiler
Information
Performance data for boiler model. See the documentation of Buildings.Fluid.Boilers.Data.Lochinvar.
Extends from Buildings.Fluid.Boilers.Data.Lochinvar.FTXL.FTX400 (Specifications for Lochinvar FTXL FTX400 boiler).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | effCur[:, :] | [0, 294.264548954895, 299.82... | Efficiency curves as a table: First row = inlet temp(K), First column = firing rates or PLR |
| Temperature | TIn_nominal | 323.15 | Nominal inlet temperature for efficiency calculations [K] |
| Power | Q_flow_nominal | 143311.7532 | Nominal heating power [W] |
| ThermalConductance | UA | 0.05*Q_flow_nominal/30 | Overall UA value [W/K] |
| Volume | VWat | 0.045424941 | Water volume of boiler [m3] |
| Mass | mDry | 228.6105545 | Mass of boiler that will be lumped to water heat capacity [kg] |
| MassFlowRate | m_flow_nominal | 3.091420 | Nominal mass flow rate [kg/s] |
| PressureDifference | dp_nominal | 3.091420 | Pressure drop at m_flow_nominal [Pa] |
Modelica definition
Buildings.Fluid.Boilers.Data.Lochinvar.FTXL.FTX600
Specifications for Lochinvar FTXL FTX600 boiler
Information
Performance data for boiler model. See the documentation of Buildings.Fluid.Boilers.Data.Lochinvar.
Extends from Buildings.Fluid.Boilers.Data.Lochinvar.FTXL.FTX400 (Specifications for Lochinvar FTXL FTX400 boiler).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | effCur[:, :] | [0, 294.264548954895, 299.82... | Efficiency curves as a table: First row = inlet temp(K), First column = firing rates or PLR |
| Temperature | TIn_nominal | 323.15 | Nominal inlet temperature for efficiency calculations [K] |
| Power | Q_flow_nominal | 171446.576 | Nominal heating power [W] |
| ThermalConductance | UA | 0.05*Q_flow_nominal/30 | Overall UA value [W/K] |
| Volume | VWat | 0.045424941 | Water volume of boiler [m3] |
| Mass | mDry | 228.6105545 | Mass of boiler that will be lumped to water heat capacity [kg] |
| MassFlowRate | m_flow_nominal | 3.722322 | Nominal mass flow rate [kg/s] |
| PressureDifference | dp_nominal | 13151.51 | Pressure drop at m_flow_nominal [Pa] |
Modelica definition
Buildings.Fluid.Boilers.Data.Lochinvar.FTXL.FTX725
Specifications for Lochinvar FTXL FTX725 boiler
Information
Performance data for boiler model. See the documentation of Buildings.Fluid.Boilers.Data.Lochinvar.
Extends from Buildings.Fluid.Boilers.Data.Lochinvar.FTXL.FTX400 (Specifications for Lochinvar FTXL FTX400 boiler).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | effCur[:, :] | [0, 294.264548954895, 299.82... | Efficiency curves as a table: First row = inlet temp(K), First column = firing rates or PLR |
| Temperature | TIn_nominal | 323.15 | Nominal inlet temperature for efficiency calculations [K] |
| Power | Q_flow_nominal | 206615.1044 | Nominal heating power [W] |
| ThermalConductance | UA | 0.05*Q_flow_nominal/30 | Overall UA value [W/K] |
| Volume | VWat | 0.064352 | Water volume of boiler [m3] |
| Mass | mDry | 260.8156128 | Mass of boiler that will be lumped to water heat capacity [kg] |
| MassFlowRate | m_flow_nominal | 4.479404 | Nominal mass flow rate [kg/s] |
| PressureDifference | dp_nominal | 14646.00 | Pressure drop at m_flow_nominal [Pa] |
Modelica definition
Buildings.Fluid.Boilers.Data.Lochinvar.FTXL.FTX850
Specifications for Lochinvar FTXL FTX850 boiler
Information
Performance data for boiler model. See the documentation of Buildings.Fluid.Boilers.Data.Lochinvar.
Extends from Buildings.Fluid.Boilers.Data.Lochinvar.FTXL.FTX400 (Specifications for Lochinvar FTXL FTX400 boiler).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | effCur[:, :] | [0, 294.264548954895, 299.82... | Efficiency curves as a table: First row = inlet temp(K), First column = firing rates or PLR |
| Temperature | TIn_nominal | 323.15 | Nominal inlet temperature for efficiency calculations [K] |
| Power | Q_flow_nominal | 241637.0972 | Nominal heating power [W] |
| ThermalConductance | UA | 0.05*Q_flow_nominal/30 | Overall UA value [W/K] |
| Volume | VWat | 0.060566589 | Water volume of boiler [m3] |
| Mass | mDry | 273.9697915 | Mass of boiler that will be lumped to water heat capacity [kg] |
| MassFlowRate | m_flow_nominal | 5.236486 | Nominal mass flow rate [kg/s] |
| PressureDifference | dp_nominal | 17037.19 | Pressure drop at m_flow_nominal [Pa] |