Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel

Validation for conditional constructions but with sampled models

Information

The models in this package are identical to the models in Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions except that the models set the parameter sampleModel = true in order to verify that all initial equations are specified.

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

Name Description
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyConstructionBoundary OnlyConstructionBoundary Test model with sampleModel = true
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow OnlyExteriorWallNoWindow Test model with sampleModel = true
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindow OnlyExteriorWallWithWindow Test model with sampleModel = true
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowExteriorShade OnlyExteriorWallWithWindowExteriorShade Test model with sampleModel = true
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade OnlyExteriorWallWithWindowInteriorShade Test model with sampleModel = true
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition OnlyPartition Test model with sampleModel = true
Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlySurfaceBoundary OnlySurfaceBoundary Test model with sampleModel = true

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyConstructionBoundary Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyConstructionBoundary

Test model with sampleModel = true

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyConstructionBoundary

Information

This model is identical to Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyConstructionBoundary, except that it sets sampleModel=true.

Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyConstructionBoundary (Test model for room model).

Parameters

TypeNameDefaultDescription
IntegernConExt0Number of exterior constructions that do not have a window
IntegernConExtWin0Number of exterior constructions that do have a window
IntegernConPar0Number of partition constructions
IntegernConBou1Number of surface that are connected to constructions that are modeled inside the room
IntegernSurBou0Number of surface that are connected to the room air volume
Insulation100Concrete200matLayExt Construction material for exterior walls
Brick120matLayPar Construction material for partition walls
DoubleClearAir13ClearglaSys Data record for the glazing system

Modelica definition

model OnlyConstructionBoundary "Test model with sampleModel = true" extends Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyConstructionBoundary ( roo(sampleModel=true)); end OnlyConstructionBoundary;

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow

Test model with sampleModel = true

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallNoWindow

Information

This model is identical to Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow, except that it sets sampleModel=true.

Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow (Test model for room model).

Parameters

TypeNameDefaultDescription
IntegernConExt1Number of exterior constructions that do not have a window
IntegernConExtWin0Number of exterior constructions that do have a window
IntegernConPar0Number of partition constructions
IntegernConBou0Number of surface that are connected to constructions that are modeled inside the room
IntegernSurBou0Number of surface that are connected to the room air volume
Insulation100Concrete200matLayExt Construction material for exterior walls
Brick120matLayPar Construction material for partition walls
DoubleClearAir13ClearglaSys Data record for the glazing system

Modelica definition

model OnlyExteriorWallNoWindow "Test model with sampleModel = true" extends Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallNoWindow ( roo(sampleModel=true)); end OnlyExteriorWallNoWindow;

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindow Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindow

Test model with sampleModel = true

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindow

Information

This model is identical to Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow, except that it sets sampleModel=true.

Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow (Test model for room model).

Parameters

TypeNameDefaultDescription
IntegernConExt0Number of exterior constructions that do not have a window
IntegernConExtWin2Number of exterior constructions that do have a window
IntegernConPar0Number of partition constructions
IntegernConBou0Number of surface that are connected to constructions that are modeled inside the room
IntegernSurBou0Number of surface that are connected to the room air volume
Insulation100Concrete200matLayExt Construction material for exterior walls
Brick120matLayPar Construction material for partition walls
DoubleClearAir13ClearglaSys Data record for the glazing system

Modelica definition

model OnlyExteriorWallWithWindow "Test model with sampleModel = true" extends Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindow ( roo(sampleModel=true)); end OnlyExteriorWallWithWindow;

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowExteriorShade Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowExteriorShade

Test model with sampleModel = true

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowExteriorShade

Information

This model is identical to Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowExteriorShade, except that it sets sampleModel=true.

Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowExteriorShade (Test model for room model).

Parameters

TypeNameDefaultDescription
IntegernConExt0Number of exterior constructions that do not have a window
IntegernConExtWin2Number of exterior constructions that do have a window
IntegernConPar0Number of partition constructions
IntegernConBou0Number of surface that are connected to constructions that are modeled inside the room
IntegernSurBou0Number of surface that are connected to the room air volume
Insulation100Concrete200matLayExt Construction material for exterior walls
Brick120matLayPar Construction material for partition walls
DoubleClearAir13ClearglaSysglaSys(haveExteriorShade=true)Data record for the glazing system

Modelica definition

model OnlyExteriorWallWithWindowExteriorShade "Test model with sampleModel = true" extends Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowExteriorShade ( roo(sampleModel=true)); end OnlyExteriorWallWithWindowExteriorShade;

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade

Test model with sampleModel = true

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade

Information

This model is identical to Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade, except that it sets sampleModel=true.

Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade (Test model for room model).

Parameters

TypeNameDefaultDescription
IntegernConExt0Number of exterior constructions that do not have a window
IntegernConExtWin2Number of exterior constructions that do have a window
IntegernConPar0Number of partition constructions
IntegernConBou0Number of surface that are connected to constructions that are modeled inside the room
IntegernSurBou0Number of surface that are connected to the room air volume
Insulation100Concrete200matLayExt Construction material for exterior walls
Brick120matLayPar Construction material for partition walls
DoubleClearAir13ClearglaSysglaSys(haveInteriorShade=true)Data record for the glazing system

Modelica definition

model OnlyExteriorWallWithWindowInteriorShade "Test model with sampleModel = true" extends Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowInteriorShade ( roo(sampleModel=true)); end OnlyExteriorWallWithWindowInteriorShade;

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition

Test model with sampleModel = true

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyPartition

Information

This model is identical to Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition, except that it sets sampleModel=true.

Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition (Test model for room model).

Parameters

TypeNameDefaultDescription
IntegernConExt0Number of exterior constructions that do not have a window
IntegernConExtWin0Number of exterior constructions that do have a window
IntegernConPar1Number of partition constructions
IntegernConBou0Number of surface that are connected to constructions that are modeled inside the room
IntegernSurBou0Number of surface that are connected to the room air volume
Insulation100Concrete200matLayExt Construction material for exterior walls
Brick120matLayPar Construction material for partition walls
DoubleClearAir13ClearglaSys Data record for the glazing system

Modelica definition

model OnlyPartition "Test model with sampleModel = true" extends Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyPartition ( roo(sampleModel=true)); end OnlyPartition;

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlySurfaceBoundary Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlySurfaceBoundary

Test model with sampleModel = true

Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlySurfaceBoundary

Information

This model is identical to Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary, except that it sets sampleModel=true.

Extends from Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary (Test model for room model).

Parameters

TypeNameDefaultDescription
IntegernConExt0Number of exterior constructions that do not have a window
IntegernConExtWin0Number of exterior constructions that do have a window
IntegernConPar0Number of partition constructions
IntegernConBou0Number of surface that are connected to constructions that are modeled inside the room
IntegernSurBou1Number of surface that are connected to the room air volume
Insulation100Concrete200matLayExt Construction material for exterior walls
Brick120matLayPar Construction material for partition walls
DoubleClearAir13ClearglaSys Data record for the glazing system

Modelica definition

model OnlySurfaceBoundary "Test model with sampleModel = true" extends Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlySurfaceBoundary ( roo(sampleModel=true)); end OnlySurfaceBoundary;