Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.Generic.BaseClasses
Package with base classes for performance data
Information
This package contains performance curves for the cooling capacity and the EIR of air-cooled DX cooling coils. For performance data of specific air-cooled DX cooling coils, see the packages Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.SingleSpeed and Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.DoubleSpeed.
The data are described in Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.Generic.DXCoil.
Extends from Modelica.Icons.BasesPackage (Icon for packages containing base classes).
Package Content
| Name | Description |
|---|---|
| Converts the nominal values to a string representation | |
| Data record of nominal values | |
| Data record for a performance curve | |
| Generic data record for a stage of a air-cooled DX coil |
Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.Generic.BaseClasses.nominalValuesToString
Converts the nominal values to a string representation
Information
Returns a string representation of the nominal values.
Extends from Modelica.Icons.Function (Icon for functions).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| NominalValues | nomVal | Nominal values |
Outputs
| Type | Name | Description |
|---|---|---|
| String | s | A string representation of the nominal values |
Modelica definition
Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.Generic.BaseClasses.NominalValues
Data record of nominal values
Information
This is the base record of nominal values for air-cooled DX cooling coil models.
See the information section of Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.Generic.DXCoil for a description of the data.
Extends from Modelica.Icons.Record (Icon for records).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Nominal condition | |||
| HeatFlowRate | Q_flow_nominal | Nominal cooling capacity (negative number) [W] | |
| Real | COP_nominal | Nominal coefficient of performance | |
| Real | SHR_nominal | Nominal sensible heat ratio | |
| MassFlowRate | m_flow_nominal | Nominal air mass flow rate at evaporators [kg/s] | |
| Temperature | TEvaIn_nominal | 273.15 + 19.4 | Evaporator entering air wet-bulb temperature at rating condition [K] |
| Temperature | TConIn_nominal | 308.15 | Condenser entering temperature at rating condition (wet bulb for evaporative cooled coils, dry bulb for air cooled) [K] |
| Pressure | p_nominal | 101325 | Atmospheric pressure [Pa] |
| Nominal | |||
| Real | phiIn_nominal | 0.5 | Relative humidity of entering air at nominal condition |
| Re-evaporation data | |||
| Time | tWet | 1400 | Time until moisture drips from coil when a dry coil is switched on [s] |
| Real | gamma | 1.5 | Ratio of evaporation heat transfer divided by latent heat transfer at nominal conditions |
Modelica definition
Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.Generic.BaseClasses.PerformanceCurve
Data record for a performance curve
Information
This record declares the data used to specify performance curves for air-cooled DX coils.
See the information section of Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.Generic.DXCoil for a description of the data.
Extends from Modelica.Icons.Record (Icon for records).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Performance curves | |||
| Real | capFunT[6] | Biquadratic coefficients for cooling capacity function of temperature | |
| Real | capFunFF[:] | Polynomial coefficients for cooling capacity function of flow fration | |
| Real | EIRFunT[6] | Biquadratic coefficients for EIR function of temperature | |
| Real | EIRFunFF[:] | Polynomial coefficients for EIR function of flow fration | |
| Minimum and maximum values | |||
| Temperature | TConInMin | Minimum condenser inlet temperature for cooling capacity function [K] | |
| Temperature | TConInMax | Maximum condenser inlet temperature for cooling capacity function [K] | |
| Temperature | TEvaInMin | Minimum evaporator inlet temperature for cooling capacity function [K] | |
| Temperature | TEvaInMax | Maximum evaporator inlet temperature for cooling capacity function [K] | |
| Real | ffMin | Minimum flow fraction for which performance data are valid | |
| Real | ffMax | Maximum flow fraction for which performance data are valid | |
Modelica definition
Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.Generic.BaseClasses.Stage
Generic data record for a stage of a air-cooled DX coil
Information
This is the base record for air-cooled DX cooling coil model at a compressor speed. See the information section of Buildings.Fluid.HeatExchangers.DXCoils.AirCooled.Data.Generic.DXCoil for a description of the data.
Extends from Modelica.Icons.Record (Icon for records).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| AngularVelocity | spe | Rotational speed [rad/s] | |
| NominalValues | nomVal | redeclare parameter Building... | Nominal values |
| PerformanceCurve | perCur | redeclare parameter Building... | Performance curves for this stage |