Buildings.Fluid.SolarCollectors.Data.Concentrating
Package with SRCC rating information for concentrating solar thermal collectors
Information
Package containing data for concentrating solar collectors. All models in the Concentraing package use EN12975 test data.
Extends from Modelica.Icons.MaterialPropertiesPackage (Icon for package containing property classes).
Package Content
Name | Description |
---|---|
C_CogenraSunDeck | C - Cogenra Solar, Inc., SunDeck 1.0 |
C_VerificationModel | C - All inputs necessary for verification of EN12975 models |
Buildings.Fluid.SolarCollectors.Data.Concentrating.C_CogenraSunDeck
C - Cogenra Solar, Inc., SunDeck 1.0
Information
Necessary data for calculating dp_nominal
, G_nominal
and dT_nominal
is not provided in the EN12975 test
data. All are left blank.
References
Ratings data taken from the
Solar Rating and Certification Corporation website. SRCC# = 2011127A.
Extends from SolarCollectors.Data.GenericSolarCollector (Generic data record providing inputs for specific collector data records).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Area | ATyp | Types.Area.Aperture | Gross or aperture area |
Area | A | 4.302 | Area [m2] |
Mass | mDry | 484 | Dry weight [kg] |
Volume | V | 4.4/1000 | Fluid volume [m3] |
PressureDifference | dp_nominal | Pressure drop during test conditions [Pa] | |
Real | mperA_flow_nominal | 0.0241 | Mass flow rate per unit area of collector [kg/(s.m2)] |
Real | B0 | 0 | 1st incident angle modifier coefficient |
Real | B1 | 0 | 2nd incident angle modifier coefficient |
Real | y_intercept | 0.720 | Y intercept (Maximum efficiency) |
Real | slope | 0 | Slope from rating data [W/(m2.K)] |
Real | IAMDiff | 0.133 | Incidence angle modifier from EN12975 ratings data |
Real | C1 | 2.8312 | Heat loss coefficient from EN12975 ratings data |
Real | C2 | 0.00119 | Temperature dependence of heat loss from EN12975 ratings data |
Irradiance | G_nominal | Nominal solar irradiance specified in ratings data [W/m2] | |
TemperatureDifference | dT_nominal | Nominal temperature difference specified in ratings data [K] |
Modelica definition
Buildings.Fluid.SolarCollectors.Data.Concentrating.C_VerificationModel
C - All inputs necessary for verification of EN12975 models
Information
No model on the Solar Rating and
Certification Corporation website tested to EN12975 standards provides all
of the necessary information for modeling. Specific limitations are
dp_nominal
, G_nominal
and dT_nominal
.
This data record was created to allow verification of EN12975 base classes
despite the limitations in available data.
Extends from SolarCollectors.Data.GenericSolarCollector (Generic data record providing inputs for specific collector data records).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Area | ATyp | Types.Area.Aperture | Gross or aperture area |
Area | A | 4.302 | Area [m2] |
Mass | mDry | 484 | Dry weight [kg] |
Volume | V | 4.4/1000 | Fluid volume [m3] |
PressureDifference | dp_nominal | 100 | Pressure drop during test conditions [Pa] |
Real | mperA_flow_nominal | 0.0241 | Mass flow rate per unit area of collector [kg/(s.m2)] |
Real | B0 | 0 | 1st incident angle modifier coefficient |
Real | B1 | 0 | 2nd incident angle modifier coefficient |
Real | y_intercept | 0.720 | Y intercept (Maximum efficiency) |
Real | slope | 0 | Slope from rating data [W/(m2.K)] |
Real | IAMDiff | 0.133 | Incidence angle modifier from EN12975 ratings data |
Real | C1 | 2.8312 | Heat loss coefficient from EN12975 ratings data |
Real | C2 | 0.00119 | Temperature dependence of heat loss from EN12975 ratings data |
Irradiance | G_nominal | 1000 | Nominal solar irradiance specified in ratings data [W/m2] |
TemperatureDifference | dT_nominal | 20 | Nominal temperature difference specified in ratings data [K] |