Buildings.Electrical.PhaseSystems.TwoConductor
Two conductors for DC components
Information
This package declares the functions that are used to implement the DC models with double conductors.
Extends from PartialPhaseSystem (Base package of all phase systems).
Package Content
| Name | Description |
|---|---|
| Direct current has no complex component | |
| Rotate a vector of an angle theta (anti-counterclock) | |
| Return absolute angle of rotating system as offset to thetaRef | |
| Return absolute angle of rotating reference system | |
| Return phase | |
| Return phase to neutral voltages | |
| Return phase currents | |
| Return phase powers | |
| Return phase powers | |
| Return system voltage as function of phase voltages | |
| Return system current as function of phase currents | |
| Return total power as function of phase powers | |
| Inherited | |
| phaseSystemName="TwoConductor" | Name of the phase system represented by the package |
| n=2 | Number of independent voltage and current components |
| m=0 | Number of reference angles |
| Current for connector | |
| Voltage for connector | |
| Reference angle for connector | |
| Vectorized version of j | |
| Multiply two vectors | |
| Divide two vectors | |
Buildings.Electrical.PhaseSystems.TwoConductor.j
Direct current has no complex component
Information
Extends from (Return vector rotated by 90 degrees).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Real | x[n] |
Outputs
| Type | Name | Description |
|---|---|---|
| Real | y[n] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.rotate
Rotate a vector of an angle theta (anti-counterclock)
Information
Extends from (Rotate a vector of an angle theta (anti-counterclock)).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Real | x[n] | ||
| Angle | theta | [rad] |
Outputs
| Type | Name | Description |
|---|---|---|
| Real | y[n] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.thetaRel
Return absolute angle of rotating system as offset to thetaRef
Information
Extends from (Return absolute angle of rotating system as offset to thetaRef).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Angle | theta[m] | [rad] |
Outputs
| Type | Name | Description |
|---|---|---|
| Angle | thetaRel | [rad] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.thetaRef
Return absolute angle of rotating reference system
Information
Extends from (Return absolute angle of rotating reference system).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Angle | theta[m] | [rad] |
Outputs
| Type | Name | Description |
|---|---|---|
| Angle | thetaRef | [rad] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.phase
Return phase
Information
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Real | x[n] |
Outputs
| Type | Name | Description |
|---|---|---|
| Angle | phase | [rad] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.phaseVoltages
Return phase to neutral voltages
Information
Extends from (Return phase to neutral voltages).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Voltage | V | system voltage [V] | |
| Angle | phi | 0 | phase angle [rad] |
Outputs
| Type | Name | Description |
|---|---|---|
| Voltage | v[n] | phase to neutral voltages [V] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.phaseCurrents
Return phase currents
Information
Extends from (Return phase currents).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Current | I | system current [A] | |
| Angle | phi | 0 | phase angle [rad] |
Outputs
| Type | Name | Description |
|---|---|---|
| Current | i[n] | phase currents [A] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.phasePowers
Return phase powers
Information
Extends from (Return phase powers).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| ActivePower | P | active system power [W] | |
| Angle | phi | 0 | phase angle [rad] |
Outputs
| Type | Name | Description |
|---|---|---|
| Power | p[n] | phase powers [W] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.phasePowers_vi
Return phase powers
Information
Extends from (Return phase powers).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Voltage | v[n] | phase voltages [V] | |
| Current | i[n] | phase currents [A] |
Outputs
| Type | Name | Description |
|---|---|---|
| Power | p[n] | phase powers [W] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.systemVoltage
Return system voltage as function of phase voltages
Information
Extends from (Return system voltage as function of phase voltages).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Voltage | v[n] | [V] |
Outputs
| Type | Name | Description |
|---|---|---|
| Voltage | V | [V] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.systemCurrent
Return system current as function of phase currents
Information
Extends from (Return system current as function of phase currents).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Current | i[n] | [A] |
Outputs
| Type | Name | Description |
|---|---|---|
| Current | I | [A] |
Modelica definition
Buildings.Electrical.PhaseSystems.TwoConductor.activePower
Return total power as function of phase powers
Information
Extends from (Return total power as function of phase powers).
Inputs
| Type | Name | Default | Description |
|---|---|---|---|
| Voltage | v[n] | phase voltages [V] | |
| Current | i[n] | phase currents [A] |
Outputs
| Type | Name | Description |
|---|---|---|
| ActivePower | P | active system power [W] |