Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions
Constructions used in partitions contained within a test cell
Information
This package contains models of uninsulated partition walls used in the LBNL FLEXLAB facility.
Extends from Modelica.Icons.MaterialPropertiesPackage (Icon for package containing property classes).
Package Content
| Name | Description |
|---|---|
| Model of a partition door. Air is neglected | |
| Model of a partition wall. Air is neglected |
Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions.PartitionDoor
Model of a partition door. Air is neglected
Information
This is a model of a parition door. It is used in every test cell as the door between the cell itself and the closet.
Extends from Buildings.HeatTransfer.Data.OpaqueConstructions.Generic (Thermal properties of opaque constructions).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | nLay | 2 | Number of layers |
| Material | material[nLay] | {Buildings.HeatTransfer.Data... | Layer by layer declaration of material, starting from outside to room-side |
| Emissivity | absIR_a | 0.9 | Infrared absorptivity of surface a (usually outside-facing surface) [1] |
| Emissivity | absIR_b | 0.9 | Infrared absorptivity of surface b (usually room-facing surface) [1] |
| Emissivity | absSol_a | 0.5 | Solar absorptivity of surface a (usually outside-facing surface) [1] |
| Emissivity | absSol_b | 0.5 | Solar absorptivity of surface b (usually room-facing surface) [1] |
| SurfaceRoughness | roughness_a | Buildings.HeatTransfer.Types... | Exterior surface roughness |
| Advanced | |||
| Integer | nSta[nLay] | {material[i].nSta for i in 1... | Number of states (do not overwrite, used to work around Dymola 2017 bug) |
Modelica definition
Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.PartitionConstructions.PartitionWall
Model of a partition wall. Air is neglected
Information
This is a model of a partition wall. It is used in every test cell to separate the test cell itself and the attached closet.
Extends from Buildings.HeatTransfer.Data.OpaqueConstructions.Generic (Thermal properties of opaque constructions).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Integer | nLay | 2 | Number of layers |
| Material | material[nLay] | {Buildings.HeatTransfer.Data... | Layer by layer declaration of material, starting from outside to room-side |
| Emissivity | absIR_a | 0.9 | Infrared absorptivity of surface a (usually outside-facing surface) [1] |
| Emissivity | absIR_b | 0.9 | Infrared absorptivity of surface b (usually room-facing surface) [1] |
| Emissivity | absSol_a | 0.5 | Solar absorptivity of surface a (usually outside-facing surface) [1] |
| Emissivity | absSol_b | 0.5 | Solar absorptivity of surface b (usually room-facing surface) [1] |
| SurfaceRoughness | roughness_a | Buildings.HeatTransfer.Types... | Exterior surface roughness |
| Advanced | |||
| Integer | nSta[nLay] | {material[i].nSta for i in 1... | Number of states (do not overwrite, used to work around Dymola 2017 bug) |