LBL logo

Buildings.Rooms.BaseClasses.Examples.BaseClasses

Package with base classes for Buildings.Rooms.BaseClasses.Examples

Information

This package contains base classes that are used to construct the models in Buildings.Rooms.BaseClasses.Examples.

Extends from Modelica.Icons.BasesPackage (Icon for packages containing base classes).

Package Content

Name Description
PartialInfraredRadiation Partial model to test infrared radiation inside the room

Buildings.Rooms.BaseClasses.Examples.BaseClasses.PartialInfraredRadiation

Partial model to test infrared radiation inside the room

Buildings.Rooms.BaseClasses.Examples.BaseClasses.PartialInfraredRadiation

Information

Extends from Buildings.Rooms.BaseClasses.ConstructionRecords (Data records for construction data).

Parameters

TypeNameDefaultDescription
Brick120dummyCon Dummy construction to assign a parameter to the instance
SingleClear3dummyGlaSys Dummy construction to assign a parameter to the instance
Exterior constructions
IntegernConExt1Number of exterior constructions
IntegernConExtWin1Number of window constructions
Partition constructions
IntegernConPar1Number of partition constructions
Boundary constructions
IntegernConBou1Number of constructions that have their outside surface exposed to the boundary of this room
IntegernSurBou1Number of surface heat transfer models that connect to constructions that are modeled outside of this room

Modelica definition

model PartialInfraredRadiation "Partial model to test infrared radiation inside the room" extends Buildings.Rooms.BaseClasses.ConstructionRecords( nConExt=1, nConExtWin=1, nConPar=1, nConBou=1, nSurBou=1, datConExt(each A=1), datConBou(each A=1), datConExtWin(each A=1, each hWin=1, each wWin=0.5), surBou(each A=1), datConPar(each A=1)); protected Buildings.HeatTransfer.Sources.FixedTemperature bouConExt[NConExt](each T=293.15) "Boundary condition"; Modelica.Thermal.HeatTransfer.Components.ThermalConductor conConExt[NConExt](each G= 100) "Heat conductor"; Modelica.Thermal.HeatTransfer.Components.ThermalConductor conConExtWin[ NConExtWin](each G=100) "Heat conductor"; Modelica.Thermal.HeatTransfer.Components.ThermalConductor conConExtWinFra[ NConExtWin](each G=100) "Heat conductor"; Modelica.Thermal.HeatTransfer.Components.ThermalConductor conConPar_a[NConPar](each G= 100) "Heat conductor"; Modelica.Thermal.HeatTransfer.Components.ThermalConductor conConPar_b[NConPar](each G= 100) "Heat conductor"; Modelica.Thermal.HeatTransfer.Components.ThermalConductor conConBou[NConBou](each G= 100) "Heat conductor"; Modelica.Thermal.HeatTransfer.Components.ThermalConductor conSurBou[NSurBou](each G= 100) "Heat conductor"; protected Buildings.HeatTransfer.Sources.FixedTemperature bouConExtWin[ NConExtWin](each T=293.15) "Boundary condition"; Buildings.HeatTransfer.Sources.FixedTemperature bouConExtWinFra[ NConExtWin](each T=293.15) "Boundary condition"; Buildings.HeatTransfer.Sources.FixedTemperature bouConPar_a[NConPar](each T= 293.15) "Boundary condition"; Buildings.HeatTransfer.Sources.FixedTemperature bouConPar_b[NConPar](each T= 293.15) "Boundary condition"; Buildings.HeatTransfer.Sources.FixedTemperature bouConBou[NConBou](each T=293.15) "Boundary condition"; Buildings.HeatTransfer.Sources.FixedTemperature bouSurBou[NSurBou](each T=293.15) "Boundary condition"; equation connect(bouConExt.port, conConExt.port_b); connect(bouConExtWin.port, conConExtWin.port_b); connect(bouConExtWinFra.port, conConExtWinFra.port_b); connect(bouConPar_a.port, conConPar_a.port_b); connect(bouConPar_b.port, conConPar_b.port_b); connect(bouConBou.port, conConBou.port_b); connect(bouSurBou.port, conSurBou.port_b); end PartialInfraredRadiation;

Automatically generated Mon May 4 10:27:16 2015.