Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511

Package for EN15411 data records

Information

This package contains data records for heat pump data according to European Norm 14511.

Package Content

Name Description
Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.SingleSplitRXM20R SingleSplitRXM20R Daikin_FTXM20R_RXM20R heating mode
Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.Vitocal251A08 Vitocal251A08 A2W Vitocal 251 by Viessmann
Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.WAMAK_WaterToWater_220kW WAMAK_WaterToWater_220kW 220 kW water to water with R513A

Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.SingleSplitRXM20R Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.SingleSplitRXM20R

Daikin_FTXM20R_RXM20R heating mode

Information

Performance data for Daikin FTXM20R_RXM20R for the heating mode.

Boundaries are for dry-bulb temperature. Pressure drops are not provided in the datasheet.

References

Daikin, Technical data book RXM-R https://www.heizman24.de/media/pdf/fa/50/2c/Daikin-RXM-R-Produktdatenbuch.pdf

Extends from Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.GenericHeatPump (Partial heat pump data).

Contents

TypeNameDefaultDescription
RealtabPEle[:, :][0, 258.15, 263.15, 268.15, ...Electrical power consumption table, T in K, Q_flow in W
MassFlowRatemCon_flow_nominal(9.33*1.2)/60Nominal mass flow rate in condenser [kg/s]
MassFlowRatemEva_flow_nominal(28.3*1.2)/60Nominal mass flow rate in evaporator [kg/s]
PressureDifferencedpCon_nominal0Nominal pressure drop in condenser [Pa]
PressureDifferencedpEva_nominal0Nominal pressure drop in evaporator [Pa]
StringdevIde"DaikinRXM20R"Name of the device
Booleanuse_TEvaOutForTabfalse=true to use evaporator outlet temperature for table data, false for inlet
Booleanuse_TConOutForTabfalse=true to use condenser outlet temperature for table data, false for inlet
RealtabQCon_flow[:, :][0, 258.15, 263.15, 268.15, ...Heating output table, T in K, Q_flow in W
RealtabUppBou[:, 2][253.15, 303.15; 291.15, 303...Points to define upper boundary for sink temperature
Booleanuse_TEvaOutForOpeEnvfalse=true to use evaporator outlet temperature for operational envelope, false for inlet
Booleanuse_TConOutForOpeEnvtrue=true to use condenser outlet temperature for operational envelope, false for inlet

Modelica definition

record SingleSplitRXM20R "Daikin_FTXM20R_RXM20R heating mode" extends Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.GenericHeatPump ( use_TConOutForOpeEnv=true, use_TEvaOutForOpeEnv=false, dpEva_nominal=0, dpCon_nominal=0, tabQCon_flow=[0,258.15, 263.15, 268.15, 273.15, 280.15, 283.15; 288.15,1190,1430,1670,1940,2590,2810; 293.15,1120,1360,1600, 1860,2500,2730; 295.15,1090,1330,1570,1830,2470,2690; 297.15,1060,1300,1540,1800,2430,2660; 298.15,1040,1280,1520,1780,2410,2640; 300.15,1010,1250,1490,1760,2380,2610], tabPEle=[0,258.15, 263.15, 268.15, 273.15, 280.15, 283.15; 288.15,320,340,360,460,490,510; 293.15,330,350,370,470,500,520; 295.15,340,360,370,480,500,520; 297.15,340,360,380,480,510,530; 298.15,340, 360,380,490,510,530; 300.15,350,370,380,490,520,540], mCon_flow_nominal=(9.33*1.2)/60, mEva_flow_nominal=(28.3*1.2)/60, tabUppBou=[253.15,303.15; 291.15,303.15], devIde="DaikinRXM20R", use_TConOutForTab=false, use_TEvaOutForTab=false); end SingleSplitRXM20R;

Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.Vitocal251A08 Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.Vitocal251A08

A2W Vitocal 251 by Viessmann

Information

Data from the planning book (Planungshandbuch) from Viessmann.

While the product exists in different sizes, this record contains the data for the subtype 251-A08. If you want to model the pressure losses of the device, check out the data sheet and the installed pumps. The pressure loss depends mostly on the hydraulic system according to the datasheet.

The nominal mass flow rate is calculated for the nominal point A7/W35, with a temperature spread of 5 K.

References

Viessmann, Planungshandbuch. https://www.haustechnik-handrich.de/media/pdf/54/c4/14/vie-pa-z022164.pdf.

Extends from GenericAirToWater (Partial record for air-to-water heat pump devices).

Contents

TypeNameDefaultDescription
RealtabPEle[:, :][0, 253.15, 258.15, 266.15, ...Electrical power consumption table, T in K, Q_flow in W
MassFlowRatemCon_flow_nominal5600/5/4184Nominal mass flow rate in condenser [kg/s]
MassFlowRatemEva_flow_nominal2125/3600/1.204Nominal mass flow rate in evaporator [kg/s]
PressureDifferencedpCon_nominal0Nominal pressure drop in condenser [Pa]
PressureDifferencedpEva_nominal0Nominal pressure drop in evaporator [Pa]
StringdevIde"Vitocal251A08"Name of the device
Booleanuse_TEvaOutForTabfalse=true to use evaporator outlet temperature for table data, false for inlet
Booleanuse_TConOutForTabtrue=true to use condenser outlet temperature for table data, false for inlet
RealtabQCon_flow[:, :][0, 253.15, 258.15, 266.15, ...Heating output table, T in K, Q_flow in W
RealtabUppBou[:, 2][253.15, 333.15; 263.15, 363...Points to define upper boundary for sink temperature
Booleanuse_TEvaOutForOpeEnvfalse=true to use evaporator outlet temperature for operational envelope, false for inlet
Booleanuse_TConOutForOpeEnvtrue=true to use condenser outlet temperature for operational envelope, false for inlet

Modelica definition

record Vitocal251A08 "A2W Vitocal 251 by Viessmann" extends GenericAirToWater( dpEva_nominal=0, dpCon_nominal=0, tabUppBou=[253.15,333.15; 263.15,363.15; 313.15,363.15], use_TConOutForOpeEnv=true, use_TEvaOutForOpeEnv=false, tabQCon_flow=[ 0, 253.15, 258.15, 266.15, 275.15, 280.15, 283.15, 293.15, 303.15, 308.15; 308.15, 4490, 5170, 6470, 6790, 8000, 10210, 12330, 12310, 13090; 318.15, 4230, 4900, 6260, 6780, 8370, 9970, 11520, 13040, 12640; 328.15, 3780, 4710, 6030, 6830, 8380, 9940, 11500, 13070, 13110; 338.15, 0, 3170, 4610, 6320, 8140, 9550, 11290, 12100, 12180; 343.15, 0, 0, 3830, 5560, 7600, 8700, 11290, 12500, 12590], tabPEle=[ 0, 253.15, 258.15, 266.15, 275.15, 280.15, 283.15, 293.15, 303.15, 308.15; 308.15, 2128, 2238, 2396, 1835, 1633, 2006, 1720, 1465, 1558; 318.15, 2299, 2402, 2641, 2173, 2244, 2462, 2110, 1734, 1584; 328.15, 2305, 2631, 2899, 2493, 2669, 2915, 2556, 2164, 2081; 338.15, 0, 2032, 2478, 2760, 3095, 3375, 3085, 2521, 2511; 343.15, 0, 0, 2201, 2699, 3193, 3398, 3330, 2822, 2817], mEva_flow_nominal=2125/3600/1.204, mCon_flow_nominal=5600/5/4184, use_TConOutForTab=true, use_TEvaOutForTab=false, devIde="Vitocal251A08"); end Vitocal251A08;

Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.WAMAK_WaterToWater_220kW Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.WAMAK_WaterToWater_220kW

220 kW water to water with R513A

Information

Data for large scale (220 kW) water-to-water heat pump from WAMAK. Nominal pressure losses are the maximal values given in the datasheet, same for the nominal mass flow rates.

References

WAMAK, Produktblatt ver. 2023/24. WAMAK Product Sheets Application.

Extends from Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.GenericHeatPump (Partial heat pump data).

Contents

TypeNameDefaultDescription
RealtabPEle[:, :][0, 268.15, 269.15, 270.15, ...Electrical power consumption table, T in K, Q_flow in W
MassFlowRatemCon_flow_nominal29.07/3600*997Nominal mass flow rate in condenser [kg/s]
MassFlowRatemEva_flow_nominal27.35/3600*997Nominal mass flow rate in evaporator [kg/s]
StringdevIde"WAMAK_TWW220_WHR_HeavyDuty"Name of the device
Booleanuse_TEvaOutForTabfalse=true to use evaporator outlet temperature for table data, false for inlet
Booleanuse_TConOutForTabtrue=true to use condenser outlet temperature for table data, false for inlet
RealtabQCon_flow[:, :][0, 268.15, 269.15, 270.15, ...Heating output table, T in K, Q_flow in W
RealtabUppBou[:, 2][268.15, 328.15; 273.15, 333...Points to define upper boundary for sink temperature
Booleanuse_TEvaOutForOpeEnvfalse=true to use evaporator outlet temperature for operational envelope, false for inlet
Booleanuse_TConOutForOpeEnvtrue=true to use condenser outlet temperature for operational envelope, false for inlet

Modelica definition

record WAMAK_WaterToWater_220kW "220 kW water to water with R513A" extends Buildings.Fluid.HeatPumps.ModularReversible.Data.TableData2D.GenericHeatPump ( dpEva_nominal(displayUnit="kPa") = 40000, dpCon_nominal(displayUnit="kPa") = 40000, tabUppBou=[ 268.15, 328.15; 273.15, 333.15; 283.15, 343.15; 293.15, 353.15], mEva_flow_nominal=27.35/3600*997, mCon_flow_nominal=29.07/3600*997, tabPEle=[0, 268.15, 269.15, 270.15, 271.15, 272.15, 273.15, 274.15, 275.15, 276.15, 277.15, 278.15, 279.15, 280.15, 281.15, 282.15, 283.15, 284.15, 285.15, 286.15, 287.15, 288.15, 289.15, 290.15, 291.15, 292.15, 293.15, 294.15, 295.15, 296.15, 297.15, 298.15, 299.15, 300.15, 301.15, 302.15, 303.15, 304.15, 305.15, 306.15, 307.15, 308.15, 309.15, 310.15, 311.15, 312.15, 313.15, 314.15, 315.15, 316.15, 317.15, 318.15; 328.15, 30100, 30100, 30100, 30100, 30100, 30100, 30100, 30100, 30100, 30100, 30200, 30200, 30200, 30200, 30200, 30300, 30300, 30300, 30400, 30400, 30400, 30500, 30500, 30600, 30600, 30700, 30700, 30800, 30800, 30900, 31000, 31000, 31100, 31200, 31200, 31300, 31400, 31500, 31500, 31600, 31700, 31800, 31900, 32000, 32100, 32200, 32300, 32400, 32500, 32600, 32700; 333.15, 0, 0, 0, 0, 0, 33500, 33500, 33500, 33500, 33500, 33500, 33500, 33600, 33600, 33600, 33600, 33600, 33600, 33600, 33700, 33700, 33700, 33700, 33800, 33800, 33900, 33900, 33900, 34000, 34000, 34100, 34100, 34200, 34200, 34300, 34300, 34400, 34400, 34500, 34600, 34600, 34700, 34800, 34900, 34900, 35000, 35100, 35200, 35300, 35400, 35400; 343.15, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 41700, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41600, 41700, 41700, 41700, 41700, 41700, 41800, 41800, 41800, 41900, 41900, 41900, 42000, 42000, 42100, 42100; 353.15, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 51400, 51400, 51300, 51300, 51200, 51200, 51200, 51100, 51100, 51000, 51000, 51000, 50900, 50900, 50900, 50800, 50800, 50800, 50800, 50700, 50700, 50700, 50700, 50600, 50600, 50600], tabQCon_flow=[0, 268.15, 269.15, 270.15, 271.15, 272.15, 273.15, 274.15, 275.15, 276.15, 277.15, 278.15, 279.15, 280.15, 281.15, 282.15, 283.15, 284.15, 285.15, 286.15, 287.15, 288.15, 289.15, 290.15, 291.15, 292.15, 293.15, 294.15, 295.15, 296.15, 297.15, 298.15, 299.15, 300.15, 301.15, 302.15, 303.15, 304.15, 305.15, 306.15, 307.15, 308.15, 309.15, 310.15, 311.15, 312.15, 313.15, 314.15, 315.15, 316.15, 317.15, 318.15; 328.15, 65800, 68000, 70200, 72400, 74800, 77200, 79700, 82300, 84900, 87700, 90500, 93400, 96400, 99500, 102600, 105900, 109300, 112800, 116400, 120100, 123900, 127800, 131900, 136100, 140400, 144800, 149300, 154000, 158800, 163800, 168900, 174100, 179500, 185000, 190700, 196600, 202600, 208700, 215000, 221500, 228200, 235000, 242000, 249200, 256500, 264100, 271800, 279700, 287800, 296100, 304600; 333.15, 0, 0, 0, 0, 0, 75200, 77600, 80000, 82500, 85000, 87700, 90400, 93200, 96100, 99100, 102100, 105300, 108600, 111900, 115400, 119000, 122600, 126400, 130300, 134400, 138500, 142800, 147200, 151700, 156300, 161100, 166100, 171100, 176300, 181700, 187200, 192800, 198600, 204600, 210700, 217000, 223400, 230000, 236800, 243800, 250900, 258200, 265700, 273400, 281200, 289300; 343.15, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 95000, 97700, 100500, 103300, 106300, 109400, 112500, 115800, 119100, 122600, 126100, 129800, 133600, 137500, 141500, 145600, 149900, 154300, 158800, 163500, 168200, 173200, 178200, 183400, 188800, 194300, 199900, 205700, 211700, 217800, 224100, 230600, 237200, 244000, 250900, 258100; 353.15, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 114300, 117300, 120500, 123700, 127000, 130500, 134100, 137700, 141500, 145400, 149500, 153600, 157900, 162300, 166800, 171500, 176300, 181300, 186400, 191700, 197100, 202600, 208300, 214200, 220200, 226400], devIde="WAMAK_TWW220_WHR_HeavyDuty", use_TConOutForTab=true, use_TEvaOutForTab=false); end WAMAK_WaterToWater_220kW;