Package Content

Name Description
Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_GuangdongFSPTY95 FP_GuangdongFSPTY95 FP - Guandong Fivestar Solar Energy Co, FS-PTY95-2.0
Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_SolahartKf FP_SolahartKf FP - Solahart Kf
Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_TRNSYSValidation FP_TRNSYSValidation Default values in the TRNSYS Simulation Studio SDHW example
Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_ThermaLiteHS20 FP_ThermaLiteHS20 FP - Therma-Lite, HS-20

Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_GuangdongFSPTY95 Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_GuangdongFSPTY95

FP - Guandong Fivestar Solar Energy Co, FS-PTY95-2.0

Information

References

Ratings data taken from the Solar Rating and Certification Corporation website. SRCC# = 2012043A.

Extends from SolarCollectors.Data.GenericSolarCollector (Generic data record providing inputs for specific collector data records).

Parameters

TypeNameDefaultDescription
AreaATypTypes.Area.GrossGross or aperture area
AreaA2Area [m2]
MassmDry35Dry weight [kg]
VolumeV1.7/1000Fluid volume [m3]
PressureDifferencedp_nominal235Pressure drop during test conditions [Pa]
RealmperA_flow_nominal0.02Mass flow rate per unit area of collector [kg/(s.m2)]
RealB0-0.21651st incident angle modifier coefficient
RealB10.0232nd incident angle modifier coefficient
Realy_intercept0.678Y intercept (Maximum efficiency)
Realslope-4.426Slope from rating data [W/(m2.K)]
RealIAMDiff0Incidence angle modifier from EN12975 ratings data
RealC10Heat loss coefficient from EN12975 ratings data
RealC20Temperature dependence of heat loss from EN12975 ratings data
IrradianceG_nominal1000Nominal solar irradiance specified in ratings data [W/m2]
TemperatureDifferencedT_nominal10Nominal temperature difference specified in ratings data [K]

Modelica definition

record FP_GuangdongFSPTY95 = SolarCollectors.Data.GenericSolarCollector ( final ATyp=Types.Area.Gross, final A=2, final mDry=35, final V=1.7/1000, final dp_nominal=235, final mperA_flow_nominal=0.02, final B0=-0.2165, final B1=0.023, final y_intercept=0.678, final slope=-4.426, final IAMDiff=0, final C1=0, final C2=0, final G_nominal = 1000, final dT_nominal = 10) "FP - Guandong Fivestar Solar Energy Co, FS-PTY95-2.0";

Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_SolahartKf Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_SolahartKf

FP - Solahart Kf

Information

References

Ratings data taken from the Solar Rating and Certification Corporation website. SRCC# = 2012021A.

Extends from SolarCollectors.Data.GenericSolarCollector (Generic data record providing inputs for specific collector data records).

Parameters

TypeNameDefaultDescription
AreaATypTypes.Area.GrossGross or aperture area
AreaA2.003Area [m2]
MassmDry42Dry weight [kg]
VolumeV3.8/1000Fluid volume [m3]
PressureDifferencedp_nominal93.89Pressure drop during test conditions [Pa]
RealmperA_flow_nominal0.0194Mass flow rate per unit area of collector [kg/(s.m2)]
RealB0-0.1371st incident angle modifier coefficient
RealB10.01662nd incident angle modifier coefficient
Realy_intercept0.775Y intercept (Maximum efficiency)
Realslope-5.103Slope from rating data [W/(m2.K)]
RealIAMDiff0Incidence angle modifier from EN12975 ratings data
RealC10Heat loss coefficient from EN12975 ratings data
RealC20Temperature dependence of heat loss from EN12975 ratings data
IrradianceG_nominal1000Nominal solar irradiance specified in ratings data [W/m2]
TemperatureDifferencedT_nominal10Nominal temperature difference specified in ratings data [K]

Modelica definition

record FP_SolahartKf = SolarCollectors.Data.GenericSolarCollector ( final ATyp=Types.Area.Gross, final A=2.003, final mDry=42, final V=3.8/1000, final dp_nominal=93.89, final mperA_flow_nominal=0.0194, final B0=-0.137, final B1=0.0166, final y_intercept=0.775, final slope=-5.103, final IAMDiff=0, final C1=0, final C2=0, final G_nominal=1000, final dT_nominal=10) "FP - Solahart Kf";

Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_TRNSYSValidation Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_TRNSYSValidation

Default values in the TRNSYS Simulation Studio SDHW example

Information

Default values in the TRNSYS Simualtion Studio SDHW example. No value for dp_nominal was provided in TRNSYS, so 100 Pascal was used as a placeholder.

Extends from SolarCollectors.Data.GenericSolarCollector (Generic data record providing inputs for specific collector data records).

Parameters

TypeNameDefaultDescription
AreaATypTypes.Area.GrossGross or aperture area
AreaA5Area [m2]
MassmDry8.6Dry weight [kg]
VolumeV0.6/1000Fluid volume [m3]
PressureDifferencedp_nominal100Pressure drop during test conditions [Pa]
RealmperA_flow_nominal0.0111Mass flow rate per unit area of collector [kg/(s.m2)]
RealB0-0.21st incident angle modifier coefficient
RealB1-02nd incident angle modifier coefficient
Realy_intercept0.8Y intercept (Maximum efficiency)
Realslope-3.6111Slope from rating data [W/(m2.K)]
RealIAMDiff0Incidence angle modifier from EN12975 ratings data
RealC10Heat loss coefficient from EN12975 ratings data
RealC20Temperature dependence of heat loss from EN12975 ratings data
IrradianceG_nominal800Nominal solar irradiance specified in ratings data [W/m2]
TemperatureDifferencedT_nominal10Nominal temperature difference specified in ratings data [K]

Modelica definition

record FP_TRNSYSValidation = SolarCollectors.Data.GenericSolarCollector ( ATyp=Types.Area.Gross, A=5, mDry=8.6, V=0.6/1000, dp_nominal=100, mperA_flow_nominal=0.0111, B0=-0.2, B1=-0, y_intercept=0.8, slope=-3.6111, IAMDiff=0, C1=0, C2=0, G_nominal=800, dT_nominal=10) "Default values in the TRNSYS Simulation Studio SDHW example";

Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_ThermaLiteHS20 Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_ThermaLiteHS20

FP - Therma-Lite, HS-20

Information

References

Ratings data taken from the Solar Rating and Certification Corporation website. SRCC# = 2012047A.

Extends from SolarCollectors.Data.GenericSolarCollector (Generic data record providing inputs for specific collector data records).

Parameters

TypeNameDefaultDescription
AreaATypTypes.Area.GrossGross or aperture area
AreaA1.97Area [m2]
MassmDry26Dry weight [kg]
VolumeV2.8/1000Fluid volume [m3]
PressureDifferencedp_nominal242.65Pressure drop during test conditions [Pa]
RealmperA_flow_nominal0.1777Mass flow rate per unit area of collector [kg/(s.m2)]
RealB0-0.06931st incident angle modifier coefficient
RealB1-0.23722nd incident angle modifier coefficient
Realy_intercept0.762Y intercept (Maximum efficiency)
Realslope-3.710Slope from rating data [W/(m2.K)]
RealIAMDiff0Incidence angle modifier from EN12975 ratings data
RealC10Heat loss coefficient from EN12975 ratings data
RealC20Temperature dependence of heat loss from EN12975 ratings data
IrradianceG_nominal1000Nominal solar irradiance specified in ratings data [W/m2]
TemperatureDifferencedT_nominal10Nominal temperature difference specified in ratings data [K]

Modelica definition

record FP_ThermaLiteHS20 = SolarCollectors.Data.GenericSolarCollector ( final ATyp=Types.Area.Gross, final A=1.97, final mDry=26, final V=2.8/1000, final dp_nominal=242.65, final mperA_flow_nominal=0.1777, final B0=-0.0693, final B1=-0.2372, final y_intercept=0.762, final slope=-3.710, final IAMDiff=0, final C1=0, final C2=0, final G_nominal = 1000, final dT_nominal = 10) "FP - Therma-Lite, HS-20";