Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.DividingWalls
Walls used to divide test beds and cells
Information
This package contains models of walls used to separate rooms, test cells, and test beds in the LBNL FLEXLAB facility.
Extends from Modelica.Icons.MaterialPropertiesPackage (Icon for package containing property classes).
Package Content
Name | Description |
---|---|
CellAndElectricalDividingWall | Wall separating FLEXLAB test cells from the adjoining electrical rooms |
ClosetAndElectricalDividingWall | Wall separating FLEXLAB closets from the adjoining electrical rooms |
TestBedDividingWall | Wall separating test beds |
TestCellDividngWall | Wall separating test cells within a test bed |
Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.DividingWalls.CellAndElectricalDividingWall
Wall separating FLEXLAB test cells from the adjoining
electrical rooms
Information
This is a construction of a dividing wall commonly found in FLEXLAB test cells. It is used to divide one test cell from another (cell A and cell B) as well as separate the test cell from the connected electrical room.
Extends from Buildings.HeatTransfer.Data.OpaqueConstructions.Generic (Thermal properties of opaque constructions).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Integer | nLay | 5 | Number of layers |
Material | material[nLay] | {Buildings.HeatTransfer.Data... | Layer by layer declaration of material, starting from outside to room-side |
Emissivity | absIR_a | 0.9 | Infrared absorptivity of surface a (usually outside-facing surface) [1] |
Emissivity | absIR_b | 0.9 | Infrared absorptivity of surface b (usually room-facing surface) [1] |
Emissivity | absSol_a | 0.5 | Solar absorptivity of surface a (usually outside-facing surface) [1] |
Emissivity | absSol_b | 0.5 | Solar absorptivity of surface b (usually room-facing surface) [1] |
SurfaceRoughness | roughness_a | Buildings.HeatTransfer.Types... | Exterior surface roughness |
Modelica definition
Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.DividingWalls.ClosetAndElectricalDividingWall
Wall separating FLEXLAB closets from the adjoining
electrical rooms
Information
This is a dividing wall found in FLEXLAB test cells. It is commonly used to separate the electrical room and closet.
Extends from Buildings.HeatTransfer.Data.OpaqueConstructions.Generic (Thermal properties of opaque constructions).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Integer | nLay | 6 | Number of layers |
Material | material[nLay] | {Buildings.HeatTransfer.Data... | Layer by layer declaration of material, starting from outside to room-side |
Emissivity | absIR_a | 0.9 | Infrared absorptivity of surface a (usually outside-facing surface) [1] |
Emissivity | absIR_b | 0.9 | Infrared absorptivity of surface b (usually room-facing surface) [1] |
Emissivity | absSol_a | 0.5 | Solar absorptivity of surface a (usually outside-facing surface) [1] |
Emissivity | absSol_b | 0.5 | Solar absorptivity of surface b (usually room-facing surface) [1] |
SurfaceRoughness | roughness_a | Buildings.HeatTransfer.Types... | Exterior surface roughness |
Modelica definition
Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.DividingWalls.TestBedDividingWall
Wall separating test beds
Information
This is a dividing wall commonly found in FLEXLAB test cells. It is used to separate one test cell from another (For example, it is found between test cells X2B and X3A).
Extends from Buildings.HeatTransfer.Data.OpaqueConstructions.Generic (Thermal properties of opaque constructions).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Integer | nLay | 10 | Number of layers |
Material | material[nLay] | {Buildings.HeatTransfer.Data... | Layer by layer declaration of material, starting from outside to room-side |
Emissivity | absIR_a | 0.9 | Infrared absorptivity of surface a (usually outside-facing surface) [1] |
Emissivity | absIR_b | 0.9 | Infrared absorptivity of surface b (usually room-facing surface) [1] |
Emissivity | absSol_a | 0.5 | Solar absorptivity of surface a (usually outside-facing surface) [1] |
Emissivity | absSol_b | 0.5 | Solar absorptivity of surface b (usually room-facing surface) [1] |
SurfaceRoughness | roughness_a | Buildings.HeatTransfer.Types... | Exterior surface roughness |
Modelica definition
Buildings.ThermalZones.Detailed.FLEXLAB.Data.Constructions.OpaqueConstructions.DividingWalls.TestCellDividngWall
Wall separating test cells within a test bed
Information
This is a dividing wall used to separate test cells within a given test bed. For example, it is installed between test cells X3A and X3B.
Extends from Buildings.HeatTransfer.Data.OpaqueConstructions.Generic (Thermal properties of opaque constructions).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Integer | nLay | 7 | Number of layers |
Material | material[nLay] | {Buildings.HeatTransfer.Data... | Layer by layer declaration of material, starting from outside to room-side |
Emissivity | absIR_a | 0.9 | Infrared absorptivity of surface a (usually outside-facing surface) [1] |
Emissivity | absIR_b | 0.9 | Infrared absorptivity of surface b (usually room-facing surface) [1] |
Emissivity | absSol_a | 0.5 | Solar absorptivity of surface a (usually outside-facing surface) [1] |
Emissivity | absSol_b | 0.5 | Solar absorptivity of surface b (usually room-facing surface) [1] |
SurfaceRoughness | roughness_a | Buildings.HeatTransfer.Types... | Exterior surface roughness |