Buildings.Templates.ZoneEquipment.Validation.UserProject.ZoneEquipment
Zone equipment
Information
This package contains models used for validation purposes.
Extends from Modelica.Icons.Package (Icon for standard packages).
Package Content
| Name | Description | 
|---|---|
|  VAVBoxCoolingOnly | Configuration of VAV terminal unit cooling only | 
|  VAVBoxCoolingOnlyControlG36 | Configuration of VAV terminal unit cooling only | 
|  VAVBoxReheatControlG36 | Configuration of VAV terminal unit with reheat | 
 Buildings.Templates.ZoneEquipment.Validation.UserProject.ZoneEquipment.VAVBoxCoolingOnly
Buildings.Templates.ZoneEquipment.Validation.UserProject.ZoneEquipment.VAVBoxCoolingOnly
Configuration of VAV terminal unit cooling only
 
Information
This is a configuration model with the same default options as Buildings.Templates.ZoneEquipment.VAVBoxCoolingOnly.
Extends from Buildings.Templates.ZoneEquipment.VAVBoxCoolingOnly (VAV terminal unit cooling only).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVBox | dat | redeclare Buildings.Template... | Design and operating parameters | 
| VAV damper | |||
| Modulating | damVAV | redeclare inner Buildings.Te... | VAV damper | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Sup | Supply air from AHU | 
| FluidPort_a | port_SupCol | Dual duct cold deck air supply from AHU | 
| FluidPort_a | port_SupHot | Dual duct hot deck air supply from AHU | 
| FluidPort_b | port_Dis | Discharge air | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| Bus | bus | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.ZoneEquipment.Validation.UserProject.ZoneEquipment.VAVBoxCoolingOnlyControlG36
Buildings.Templates.ZoneEquipment.Validation.UserProject.ZoneEquipment.VAVBoxCoolingOnlyControlG36
Configuration of VAV terminal unit cooling only
 
Information
This is a configuration model with the same default options as
Buildings.Templates.ZoneEquipment.VAVBoxReheat
except for the following options.
| Component | Configuration | 
|---|---|
| Controller | Guideline 36 controller | 
Extends from Buildings.Templates.ZoneEquipment.VAVBoxCoolingOnly (VAV terminal unit cooling only).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVBox | dat | redeclare Buildings.Template... | Design and operating parameters | 
| VAV damper | |||
| Modulating | damVAV | redeclare inner Buildings.Te... | VAV damper | 
| Controller | |||
| G36VAVBoxCoolingOnly | ctl | redeclare replaceable Buildi... | Control selections | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Sup | Supply air from AHU | 
| FluidPort_a | port_SupCol | Dual duct cold deck air supply from AHU | 
| FluidPort_a | port_SupHot | Dual duct hot deck air supply from AHU | 
| FluidPort_b | port_Dis | Discharge air | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| Bus | bus | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.ZoneEquipment.Validation.UserProject.ZoneEquipment.VAVBoxReheatControlG36
Buildings.Templates.ZoneEquipment.Validation.UserProject.ZoneEquipment.VAVBoxReheatControlG36
Configuration of VAV terminal unit with reheat
 
Information
This is a configuration model with the same default options as
Buildings.Templates.ZoneEquipment.VAVBoxReheat
except for the following options.
| Component | Configuration | 
|---|---|
| Controller | Guideline 36 controller | 
Extends from Buildings.Templates.ZoneEquipment.VAVBoxReheat (VAV terminal unit with reheat).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVBox | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Heating coil | |||
| WaterBasedHeating | coiHea | redeclare inner Buildings.Te... | Heating coil | 
| VAV damper | |||
| Modulating | damVAV | redeclare inner Buildings.Te... | VAV damper | 
| Controller | |||
| G36VAVBoxReheat | ctl | redeclare replaceable Buildi... | Control selections | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Sup | Supply air from AHU | 
| FluidPort_a | port_SupCol | Dual duct cold deck air supply from AHU | 
| FluidPort_a | port_SupHot | Dual duct hot deck air supply from AHU | 
| FluidPort_b | port_Dis | Discharge air | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| Bus | bus | Terminal unit control bus | 