Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans
Air handlers and fans
Information
This package contains models used for validation purposes.
Extends from Modelica.Icons.Package (Icon for standard packages).
Package Content
| Name | Description | 
|---|---|
|  VAVMZBase | Configuration of multiple-zone VAV | 
|  VAVMZCoilElectricHeating | Configuration of multiple-zone VAV | 
|  VAVMZCoilEvaporatorMultiStage | Configuration of multiple-zone VAV | 
|  VAVMZCoilEvaporatorVariable | Configuration of multiple-zone VAV | 
|  VAVMZCoilWaterHeating3WVReheat | Configuration of multiple-zone VAV | 
|  VAVMZControlG36Airflow | Configuration of multiple-zone VAV | 
|  VAVMZControlG36Pressure | Configuration of multiple-zone VAV | 
|  VAVMZDedicatedDampersPressure | Configuration of multiple-zone VAV | 
|  VAVMZFanRelief | Configuration of multiple-zone VAV | 
|  VAVMZFanSupplyBlowThrough | Configuration of multiple-zone VAV | 
 Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZBase
Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZBase
Configuration of multiple-zone VAV
 
Information
This is a configuration model with the same default options as
Buildings.Templates.AirHandlersFans.VAVMultiZone
except for the following options.
| Component | Configuration | 
|---|---|
| Outdoor air section | No economizer | 
| Relief/return air section | No economizer | 
Extends from VAVMultiZone (Multiple-zone VAV).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumChiWat | Water | CHW medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVMultiZone | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Configuration | |||
| Integer | nZon | 2 | Number of served zones | 
| MixedAirWithDamper | secOutRel | Outdoor/relief/return air section | |
| None | fanSupBlo | redeclare inner Buildings.Te... | Supply fan - Blow through | 
| SingleVariable | fanSupDra | redeclare inner Buildings.Te... | Supply fan - Draw through | 
| WaterBasedHeating | coiHeaPre | redeclare inner Buildings.Te... | Heating coil in preheat position | 
| WaterBasedCooling | coiCoo | redeclare inner Buildings.Te... | Cooling coil | 
| None | coiHeaReh | redeclare inner Buildings.Te... | Heating coil in reheat position | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Out | Outdoor air intake | 
| FluidPort_b | port_Sup | Supply air | 
| FluidPort_b | port_SupCol | Dual duct cold deck air supply | 
| FluidPort_b | port_SupHot | Dual duct hot deck air supply | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_b | port_Rel | Relief (exhaust) air | 
| FluidPort_b | port_bChiWat | CHW return port | 
| FluidPort_a | port_aChiWat | CHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| Bus | bus | AHU control bus | 
| Bus | busWea | Weather bus | 
| Bus | busTer[nZon] | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZCoilElectricHeating
Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZCoilElectricHeating
Configuration of multiple-zone VAV
 
Information
This is a configuration model with the same default options as
Buildings.Templates.AirHandlersFans.VAVMultiZone
except for the following options.
| Component | Configuration | 
|---|---|
| Heating coil | Modulating electric heating coil - Preheat position | 
Extends from Buildings.Templates.AirHandlersFans.VAVMultiZone (Multiple-zone VAV).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumChiWat | Water | CHW medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVMultiZone | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Configuration | |||
| Integer | nZon | 2 | Number of served zones | 
| MixedAirWithDamper | secOutRel | Outdoor/relief/return air section | |
| None | fanSupBlo | redeclare inner Buildings.Te... | Supply fan - Blow through | 
| SingleVariable | fanSupDra | redeclare inner Buildings.Te... | Supply fan - Draw through | 
| WaterBasedCooling | coiCoo | redeclare inner Buildings.Te... | Cooling coil | 
| None | coiHeaReh | redeclare inner Buildings.Te... | Heating coil in reheat position | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Out | Outdoor air intake | 
| FluidPort_b | port_Sup | Supply air | 
| FluidPort_b | port_SupCol | Dual duct cold deck air supply | 
| FluidPort_b | port_SupHot | Dual duct hot deck air supply | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_b | port_Rel | Relief (exhaust) air | 
| FluidPort_b | port_bChiWat | CHW return port | 
| FluidPort_a | port_aChiWat | CHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| Bus | bus | AHU control bus | 
| Bus | busWea | Weather bus | 
| Bus | busTer[nZon] | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZCoilEvaporatorMultiStage
Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZCoilEvaporatorMultiStage
Configuration of multiple-zone VAV
 
Information
This is a configuration model with the same default options as
Buildings.Templates.AirHandlersFans.VAVMultiZone
except for the following options.
| Component | Configuration | 
|---|---|
| Cooling coil | Evaporator coil with multi-stage compressor | 
Extends from Buildings.Templates.AirHandlersFans.VAVMultiZone (Multiple-zone VAV).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumChiWat | Water | CHW medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVMultiZone | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Configuration | |||
| Integer | nZon | 2 | Number of served zones | 
| MixedAirWithDamper | secOutRel | Outdoor/relief/return air section | |
| None | fanSupBlo | redeclare inner Buildings.Te... | Supply fan - Blow through | 
| SingleVariable | fanSupDra | redeclare inner Buildings.Te... | Supply fan - Draw through | 
| WaterBasedHeating | coiHeaPre | redeclare inner Buildings.Te... | Heating coil in preheat position | 
| None | coiHeaReh | redeclare inner Buildings.Te... | Heating coil in reheat position | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Out | Outdoor air intake | 
| FluidPort_b | port_Sup | Supply air | 
| FluidPort_b | port_SupCol | Dual duct cold deck air supply | 
| FluidPort_b | port_SupHot | Dual duct hot deck air supply | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_b | port_Rel | Relief (exhaust) air | 
| FluidPort_b | port_bChiWat | CHW return port | 
| FluidPort_a | port_aChiWat | CHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| Bus | bus | AHU control bus | 
| Bus | busWea | Weather bus | 
| Bus | busTer[nZon] | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZCoilEvaporatorVariable
Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZCoilEvaporatorVariable
Configuration of multiple-zone VAV
 
Information
This is a configuration model with the same default options as
Buildings.Templates.AirHandlersFans.VAVMultiZone
except for the following options.
| Component | Configuration | 
|---|---|
| Cooling coil | Evaporator coil with variable speed compressor | 
Extends from Buildings.Templates.AirHandlersFans.VAVMultiZone (Multiple-zone VAV).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumChiWat | Water | CHW medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVMultiZone | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Configuration | |||
| Integer | nZon | 2 | Number of served zones | 
| MixedAirWithDamper | secOutRel | Outdoor/relief/return air section | |
| None | fanSupBlo | redeclare inner Buildings.Te... | Supply fan - Blow through | 
| SingleVariable | fanSupDra | redeclare inner Buildings.Te... | Supply fan - Draw through | 
| WaterBasedHeating | coiHeaPre | redeclare inner Buildings.Te... | Heating coil in preheat position | 
| None | coiHeaReh | redeclare inner Buildings.Te... | Heating coil in reheat position | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Out | Outdoor air intake | 
| FluidPort_b | port_Sup | Supply air | 
| FluidPort_b | port_SupCol | Dual duct cold deck air supply | 
| FluidPort_b | port_SupHot | Dual duct hot deck air supply | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_b | port_Rel | Relief (exhaust) air | 
| FluidPort_b | port_bChiWat | CHW return port | 
| FluidPort_a | port_aChiWat | CHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| Bus | bus | AHU control bus | 
| Bus | busWea | Weather bus | 
| Bus | busTer[nZon] | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZCoilWaterHeating3WVReheat
Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZCoilWaterHeating3WVReheat
Configuration of multiple-zone VAV
 
Information
This is a configuration model with the same default options as
Buildings.Templates.AirHandlersFans.VAVMultiZone
except for the following options.
| Component | Configuration | 
|---|---|
| Heating coil | Hot water coil - Three-way modulating valve - Reheat position | 
Extends from Buildings.Templates.AirHandlersFans.VAVMultiZone (Multiple-zone VAV).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumChiWat | Water | CHW medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVMultiZone | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Configuration | |||
| Integer | nZon | 2 | Number of served zones | 
| MixedAirWithDamper | secOutRel | Outdoor/relief/return air section | |
| None | fanSupBlo | redeclare inner Buildings.Te... | Supply fan - Blow through | 
| SingleVariable | fanSupDra | redeclare inner Buildings.Te... | Supply fan - Draw through | 
| WaterBasedCooling | coiCoo | redeclare inner Buildings.Te... | Cooling coil | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Out | Outdoor air intake | 
| FluidPort_b | port_Sup | Supply air | 
| FluidPort_b | port_SupCol | Dual duct cold deck air supply | 
| FluidPort_b | port_SupHot | Dual duct hot deck air supply | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_b | port_Rel | Relief (exhaust) air | 
| FluidPort_b | port_bChiWat | CHW return port | 
| FluidPort_a | port_aChiWat | CHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| Bus | bus | AHU control bus | 
| Bus | busWea | Weather bus | 
| Bus | busTer[nZon] | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZControlG36Airflow
Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZControlG36Airflow
Configuration of multiple-zone VAV
 
Information
This is a configuration model with the same default options as
Buildings.Templates.AirHandlersFans.VAVMultiZone
except for the following options.
| Component | Configuration | 
|---|---|
| Heating coil | Hot water coil - Two-way modulating valve - Preheat position | 
| Cooling coil | Chilled water coil - Two-way modulating valve | 
| Controller | Guideline 36 controller - Return fan with airflow tracking control | 
Extends from Buildings.Templates.AirHandlersFans.VAVMultiZone (Multiple-zone VAV).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumChiWat | Water | CHW medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVMultiZone | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Configuration | |||
| Integer | nZon | 2 | Number of served zones | 
| MixedAirWithDamper | secOutRel | Outdoor/relief/return air section | |
| None | fanSupBlo | redeclare inner Buildings.Te... | Supply fan - Blow through | 
| SingleVariable | fanSupDra | redeclare inner Buildings.Te... | Supply fan - Draw through | 
| None | coiHeaReh | redeclare inner Buildings.Te... | Heating coil in reheat position | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Out | Outdoor air intake | 
| FluidPort_b | port_Sup | Supply air | 
| FluidPort_b | port_SupCol | Dual duct cold deck air supply | 
| FluidPort_b | port_SupHot | Dual duct hot deck air supply | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_b | port_Rel | Relief (exhaust) air | 
| FluidPort_b | port_bChiWat | CHW return port | 
| FluidPort_a | port_aChiWat | CHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| Bus | bus | AHU control bus | 
| Bus | busWea | Weather bus | 
| Bus | busTer[nZon] | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZControlG36Pressure
Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZControlG36Pressure
Configuration of multiple-zone VAV
 
Information
This is a configuration model with the same default options as
Buildings.Templates.AirHandlersFans.VAVMultiZone
except for the following options.
| Component | Configuration | 
|---|---|
| Heating coil | Hot water coil - Two-way modulating valve - Preheat position | 
| Cooling coil | Chilled water coil - Two-way modulating valve | 
| Controller | Guideline 36 controller - Return fan with building pressure control | 
Extends from Buildings.Templates.AirHandlersFans.VAVMultiZone (Multiple-zone VAV).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumChiWat | Water | CHW medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVMultiZone | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Configuration | |||
| Integer | nZon | 2 | Number of served zones | 
| MixedAirWithDamper | secOutRel | Outdoor/relief/return air section | |
| None | fanSupBlo | redeclare inner Buildings.Te... | Supply fan - Blow through | 
| SingleVariable | fanSupDra | redeclare inner Buildings.Te... | Supply fan - Draw through | 
| None | coiHeaReh | redeclare inner Buildings.Te... | Heating coil in reheat position | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Out | Outdoor air intake | 
| FluidPort_b | port_Sup | Supply air | 
| FluidPort_b | port_SupCol | Dual duct cold deck air supply | 
| FluidPort_b | port_SupHot | Dual duct hot deck air supply | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_b | port_Rel | Relief (exhaust) air | 
| FluidPort_b | port_bChiWat | CHW return port | 
| FluidPort_a | port_aChiWat | CHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| Bus | bus | AHU control bus | 
| Bus | busWea | Weather bus | 
| Bus | busTer[nZon] | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZDedicatedDampersPressure
Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZDedicatedDampersPressure
Configuration of multiple-zone VAV
 
Information
This is a configuration model with the same default options as
Buildings.Templates.AirHandlersFans.VAVMultiZone
except for the following options.
| Component | Configuration | 
|---|---|
| Outdoor air section | Separate dedicated OA dampers with differential pressure sensor | 
Extends from Buildings.Templates.AirHandlersFans.VAVMultiZone (Multiple-zone VAV).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumChiWat | Water | CHW medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVMultiZone | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Configuration | |||
| Integer | nZon | 2 | Number of served zones | 
| None | fanSupBlo | redeclare inner Buildings.Te... | Supply fan - Blow through | 
| SingleVariable | fanSupDra | redeclare inner Buildings.Te... | Supply fan - Draw through | 
| WaterBasedHeating | coiHeaPre | redeclare inner Buildings.Te... | Heating coil in preheat position | 
| WaterBasedCooling | coiCoo | redeclare inner Buildings.Te... | Cooling coil | 
| None | coiHeaReh | redeclare inner Buildings.Te... | Heating coil in reheat position | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Out | Outdoor air intake | 
| FluidPort_b | port_Sup | Supply air | 
| FluidPort_b | port_SupCol | Dual duct cold deck air supply | 
| FluidPort_b | port_SupHot | Dual duct hot deck air supply | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_b | port_Rel | Relief (exhaust) air | 
| FluidPort_b | port_bChiWat | CHW return port | 
| FluidPort_a | port_aChiWat | CHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| Bus | bus | AHU control bus | 
| Bus | busWea | Weather bus | 
| Bus | busTer[nZon] | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZFanRelief
Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZFanRelief
Configuration of multiple-zone VAV
 
Information
This is a configuration model with the same default options as
Buildings.Templates.AirHandlersFans.VAVMultiZone
except for the following options.
| Component | Configuration | 
|---|---|
| Relief/return air section | Relief fan with two-position relief damper | 
| Return fan | No fan | 
| Relief fan | Single fan - Variable speed | 
Extends from Buildings.Templates.AirHandlersFans.VAVMultiZone (Multiple-zone VAV).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumChiWat | Water | CHW medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVMultiZone | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Configuration | |||
| Integer | nZon | 2 | Number of served zones | 
| None | fanSupBlo | redeclare inner Buildings.Te... | Supply fan - Blow through | 
| SingleVariable | fanSupDra | redeclare inner Buildings.Te... | Supply fan - Draw through | 
| WaterBasedHeating | coiHeaPre | redeclare inner Buildings.Te... | Heating coil in preheat position | 
| WaterBasedCooling | coiCoo | redeclare inner Buildings.Te... | Cooling coil | 
| None | coiHeaReh | redeclare inner Buildings.Te... | Heating coil in reheat position | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Out | Outdoor air intake | 
| FluidPort_b | port_Sup | Supply air | 
| FluidPort_b | port_SupCol | Dual duct cold deck air supply | 
| FluidPort_b | port_SupHot | Dual duct hot deck air supply | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_b | port_Rel | Relief (exhaust) air | 
| FluidPort_b | port_bChiWat | CHW return port | 
| FluidPort_a | port_aChiWat | CHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| Bus | bus | AHU control bus | 
| Bus | busWea | Weather bus | 
| Bus | busTer[nZon] | Terminal unit control bus | 
Modelica definition
 Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZFanSupplyBlowThrough
Buildings.Templates.AirHandlersFans.Validation.UserProject.AirHandlersFans.VAVMZFanSupplyBlowThrough
Configuration of multiple-zone VAV
 
Information
This is a configuration model with the same default options as
Buildings.Templates.AirHandlersFans.VAVMultiZone
except for the following options.
| Component | Configuration | 
|---|---|
| Supply fan | Single fan - Variable speed - Blow-through position | 
Extends from Buildings.Templates.AirHandlersFans.VAVMultiZone (Multiple-zone VAV).
Parameters
| Type | Name | Default | Description | 
|---|---|---|---|
| replaceable package MediumAir | Air | Air medium | |
| replaceable package MediumChiWat | Water | CHW medium | |
| replaceable package MediumHeaWat | Water | HHW medium | |
| VAVMultiZone | dat | redeclare Buildings.Template... | Design and operating parameters | 
| Configuration | |||
| Integer | nZon | 2 | Number of served zones | 
| MixedAirWithDamper | secOutRel | Outdoor/relief/return air section | |
| WaterBasedHeating | coiHeaPre | redeclare inner Buildings.Te... | Heating coil in preheat position | 
| WaterBasedCooling | coiCoo | redeclare inner Buildings.Te... | Cooling coil | 
| None | coiHeaReh | redeclare inner Buildings.Te... | Heating coil in reheat position | 
| Dynamics | |||
| Conservation equations | |||
| Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state | 
| Assumptions | |||
| Boolean | allowFlowReversalLiq | true | = true to allow flow reversal, false restricts to design direction - CHW and HW side | 
| Advanced | |||
| Diagnostics | |||
| Boolean | show_T | false | = true, if actual temperature at ports of subcomponents is computed | 
Connectors
| Type | Name | Description | 
|---|---|---|
| FluidPort_a | port_Out | Outdoor air intake | 
| FluidPort_b | port_Sup | Supply air | 
| FluidPort_b | port_SupCol | Dual duct cold deck air supply | 
| FluidPort_b | port_SupHot | Dual duct hot deck air supply | 
| FluidPort_a | port_Ret | Return air | 
| FluidPort_b | port_Rel | Relief (exhaust) air | 
| FluidPort_b | port_bChiWat | CHW return port | 
| FluidPort_a | port_aChiWat | CHW supply port | 
| FluidPort_b | port_bHeaWat | HHW return port | 
| FluidPort_a | port_aHeaWat | HHW supply port | 
| Bus | bus | AHU control bus | 
| Bus | busWea | Weather bus | 
| Bus | busTer[nZon] | Terminal unit control bus | 