Buildings.Fluid.SolarCollectors.BaseClasses
Package with base classes for Buildings.Fluid.SolarCollectors
Information
This package contains base classes that are used to construct the models in Buildings.Fluid.SolarCollectors.
Extends from Modelica.Icons.BasesPackage (Icon for packages containing base classes).
Package Content
Name | Description |
---|---|
ASHRAEHeatLoss | Calculate the heat loss of a solar collector per ASHRAE standard 93 |
ASHRAESolarGain | Calculate the solar heat gain of a solar collector per ASHRAE Standard 93 |
EN12975HeatLoss | Calculate the heat loss of a solar collector per EN12975 |
EN12975SolarGain | Model calculating solar gains per the EN12975 standard |
IAM | Function for incident angle modifer |
PartialHeatLoss | Partial heat loss model on which ASHRAEHeatLoss and EN12975HeatLoss are based |
PartialParameters | Partial model for parameters |
PartialSolarCollector | Partial model for solar collectors |
Examples | Collection of models that illustrate model use and test models |
Buildings.Fluid.SolarCollectors.BaseClasses.ASHRAEHeatLoss
Calculate the heat loss of a solar collector per ASHRAE standard 93
Information
This component computes the heat loss from the solar thermal collector to the environment. It is designed for use with ratings data collected in accordance with ASHRAE Standard 93. A negative heat loss indicates that heat is being lost to the environment.
This model calculates the heat loss to the ambient, for each segment i ∈ {1, ..., nseg} where nseg is the number of segments, as
Qlos,i = -slope Ac ⁄ nseg (Tenv-Tflu,i)
where slope < 0 is the slope for the heat loss, as specified in the ratings data, Ac is the collector area, Tenv is the environment temperature and Tflu,i is the fluid temperature in segment i ∈ {1, ..., nseg}.
This model reduces the heat loss rate to 0 when the fluid temperature is within 1 Kelvin of the minimum temperature of the medium model. The calculation is performed using the Buildings.Utilities.Math.Functions.smoothHeaviside function.
Implementation
ASHRAE uses the collector fluid inlet temperature to compute the heat loss (see Duffie and Beckmann, p. 293). However, unless the environment temperature which was present during the collector rating is known, which is not the case, one cannot compute a log mean temperature difference that would improve the UA calculation. Hence, this model is using the fluid temperature of each segment to compute the heat loss to the environment.
References
J.A. Duffie and W.A. Beckman 2006, Solar Engineering of Thermal Processes (3rd Edition),
John Wiley & Sons, Inc.
ASHRAE 93-2010 -- Methods of Testing to Determine the Thermal Performance of Solar
Collectors (ANSI approved)
Extends from Buildings.Fluid.SolarCollectors.BaseClasses.PartialHeatLoss (Partial heat loss model on which ASHRAEHeatLoss and EN12975HeatLoss are based).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Area | A_c | Area of the collector [m2] | |
Integer | nSeg | 3 | Number of segments |
Real | y_intercept | Y intercept (Maximum efficiency) | |
replaceable package Medium | PartialMedium | Medium in the component | |
SpecificHeatCapacity | cp_default | Specific heat capacity of the fluid at the default temperature [J/(kg.K)] | |
HeatFlowRate | QLos_nominal | slope*A_c*dT_nominal | Heat loss at nominal conditions, negative if heat flows from collector to environment [W] |
Real | slope | Slope from ratings data [W/(m2.K)] | |
Nominal condition | |||
Irradiance | G_nominal | Irradiance at nominal conditions [W/m2] | |
TemperatureDifference | dT_nominal | Ambient temperature minus fluid temperature at nominal conditions [K] | |
MassFlowRate | m_flow_nominal | Fluid flow rate at nominal conditions [kg/s] |
Connectors
Type | Name | Description |
---|---|---|
input RealInput | TEnv | Temperature of surrounding environment [K] |
input RealInput | TFlu[nSeg] | Temperature of the heat transfer fluid [K] |
output RealOutput | QLos[nSeg] | Limited heat loss rate at current conditions [W] |
Modelica definition
Buildings.Fluid.SolarCollectors.BaseClasses.ASHRAESolarGain
Calculate the solar heat gain of a solar collector per ASHRAE Standard 93
Information
This component computes the solar heat gain of the solar thermal collector. It only calculates the solar heat gain without considering the heat loss to the environment. This model uses ratings data according to ASHRAE93. The solar heat gain is calculated using Equations 555 - 559 in the referenced EnergyPlus documentation.
The solar radiation absorbed by the panel is identified using Eq 559 from the EnergyPlus documentation. It is
QFlow[i]=Ac/nSeg (FR(τα) K(τα)net (GDir (1-shaCoe)+GDif,Sky+GDif,Gnd))
where QFlow[i] is the heat gain in each segment, A c is the area of the collector, nSeg is the user-specified number of segments in the simulation, FR(τα) is the maximum collector efficiency, K(τα)net is the incidence angle modifier, GDir is the direct solar radiation, shaCoe is the user-specified shading coefficient, GDif,Sky is the diffuse solar radiation from the sky, and GDif,Gnd is the diffuse radiation from the ground.
The solar radiation equation indicates that the collector is divided into
multiple segments. The number of segments used in the simulation is specified
by the user (parameter: nSeg
). The area of an individual segment
is identified by dividing the collector area by the total number of segments.
The term shaCoe
is used to define the percentage of the collector
that is shaded.
The incidence angle modifier used in the solar radiation equation is found using Eq 556 from the EnergyPlus documentation. It is
K(τα),net=(GBeam K(τα), Beam+GDif,Sky K(τα),Sky+GDif,Gnd K(τα),Gnd) / (Gbeam+GDif,Sky+G Dif,Gnd)
where K(τα),net is the net incidence angle modified, GBeam is the beam radiation, K(τα),Beam is the incidence angle modifier for beam radiation, GDif,Sky is the diffuse radiation from the sky, K(τα),Sky is the incidence angle modifier for radiation from the sky, GDif, Gnd is the diffuse radiation from the ground, and K(τα),Gnd is the incidence angle modifier for diffuse radiation from the ground.
Each incidence angle modifier is calculated using Eq 555 from the EnergyPlus documentation. It is
K(τα),x=1+b0 (1/cos(θ)-1)+b1 (1/cos(θ)-1)2
where x can refer to beam, sky or ground. θ is the incidence angle. For beam radiation θ is found via standard geometry. The incidence angle for sky and ground diffuse radiation are found using, respectively, Eq 557 and 558 from the EnergyPlus documentation. They are
θsky=59.68-0.1388 til+0.001497 til2
θgnd=90.0-0.5788 til+0.002693 til2
where θsky is the incidence angle for diffuse radiation from the sky, til is the tilt of the solar thermal collector, and θgnd is the incidence angle for diffuse radiation from the ground.
These two equations must be evaluated in degrees. The necessary unit conversions are made internally.
This model reduces the heat gain rate to 0 W when the fluid temperature is within 1 degree C of the maximum temperature of the medium model. The calculation is performed using the Buildings.Utilities.Math.Functions.smoothHeaviside function.
References
EnergyPlus 7.0.0 Engineering Reference,
October 13, 2011.
ASHRAE 93-2010 -- Methods of Testing to Determine the Thermal Performance of Solar
Collectors (ANSI approved)
Extends from Modelica.Blocks.Icons.Block (Basic graphical layout of input/output block), SolarCollectors.BaseClasses.PartialParameters (Partial model for parameters).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Area | A_c | Area of the collector [m2] | |
Integer | nSeg | 3 | Number of segments |
Real | y_intercept | Y intercept (Maximum efficiency) | |
replaceable package Medium | Modelica.Media.Interfaces.Pa... | Medium in the system | |
Real | B0 | 1st incident angle modifer coefficient | |
Real | B1 | 2nd incident angle modifer coefficient | |
Angle | til | Surface tilt [rad] | |
Shading | |||
Boolean | use_shaCoe_in | false | Enable input connector for shaCoe |
Real | shaCoe | 0 | Shading coefficient 0.0: no shading, 1.0: full shading |
Connectors
Type | Name | Description |
---|---|---|
replaceable package Medium | Medium in the system | |
input RealInput | shaCoe_in | Shading coefficient |
input RealInput | TFlu[nSeg] | [K] |
input RealInput | HSkyDifTil | Diffuse solar irradiation on a tilted surfce from the sky [W/m2] |
input RealInput | HGroDifTil | Diffuse solar irradiation on a tilted surfce from the ground [W/m2] |
input RealInput | incAng | Incidence angle of the sun beam on a tilted surface [rad] |
input RealInput | HDirTil | Direct solar irradiation on a tilted surfce [W/m2] |
output RealOutput | QSol_flow[nSeg] | Solar heat gain [W] |
Modelica definition
Buildings.Fluid.SolarCollectors.BaseClasses.EN12975HeatLoss
Calculate the heat loss of a solar collector per EN12975
Information
This component computes the heat loss from the solar thermal collector to the environment. It is designed anticipating ratings data collected in accordance with EN12975. A negative heat loss indicates that heat is being lost to the environment.
This model calculates the heat loss to the ambient, for each segment i ∈ {1, ..., nseg} where nseg is the number of segments, as
Qlos,i = Ac ⁄ nseg (Tenv-Tflu,i) (C1 - C2 (Tenv-Tflu,i))
where C1 > 0 is the heat loss coefficient from EN12975 ratings data, C2 ≥ 0 is the temperature dependence of heat loss from EN12975 ratings data, Ac is the collector area, Tenv is the environment temperature and Tflu,i is the fluid temperature in segment i ∈ {1, ..., nseg}.
This model reduces the heat loss rate to 0 when the fluid temperature is within 1 Kelvin of the minimum temperature of the medium model. The calculation is performed using the Buildings.Utilities.Math.Functions.smoothHeaviside function.
Implementation
EN 12975 uses the arithmetic average temperature of the collector fluid inlet and outlet temperature to compute the heat loss (see Duffie and Beckmann, p. 293). However, unless the environment temperature that was present during the collector rating is known, which is not the case, one cannot compute a log mean temperature difference that would improve the UA calculation. Hence, this model is using the fluid temperature of each segment to compute the heat loss to the environment. If the arithmetic average temperature were used, then segments at the collector outlet could be cooled below the ambient temperature, which violates the 2nd law of Thermodynamics.
References
CEN 2006, European Standard 12975-1:2006, European Committee for Standardization
Extends from Buildings.Fluid.SolarCollectors.BaseClasses.PartialHeatLoss (Partial heat loss model on which ASHRAEHeatLoss and EN12975HeatLoss are based).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Area | A_c | Area of the collector [m2] | |
Integer | nSeg | 3 | Number of segments |
Real | y_intercept | Y intercept (Maximum efficiency) | |
replaceable package Medium | PartialMedium | Medium in the component | |
SpecificHeatCapacity | cp_default | Specific heat capacity of the fluid at the default temperature [J/(kg.K)] | |
HeatFlowRate | QLos_nominal | -A_c*(C1*dT_nominal - C2*dT_... | Heat loss at nominal conditions, negative if heat flows from collector to environment [W] |
CoefficientOfHeatTransfer | C1 | C1 from ratings data [W/(m2.K)] | |
Real | C2 | C2 from ratings data [W/(m2.K2)] | |
Nominal condition | |||
Irradiance | G_nominal | Irradiance at nominal conditions [W/m2] | |
TemperatureDifference | dT_nominal | Ambient temperature minus fluid temperature at nominal conditions [K] | |
MassFlowRate | m_flow_nominal | Fluid flow rate at nominal conditions [kg/s] |
Connectors
Type | Name | Description |
---|---|---|
input RealInput | TEnv | Temperature of surrounding environment [K] |
input RealInput | TFlu[nSeg] | Temperature of the heat transfer fluid [K] |
output RealOutput | QLos[nSeg] | Limited heat loss rate at current conditions [W] |
Modelica definition
Buildings.Fluid.SolarCollectors.BaseClasses.EN12975SolarGain
Model calculating solar gains per the EN12975 standard
Information
This component computes the solar heat gain of the solar thermal collector. It only calculates the solar heat gain without considering the heat loss to the environment. This model performs calculations using ratings data from EN12975. The solar heat gain is calculated using Equation 559 in the referenced EnergyPlus documentation. The calculation is modified somewhat to use coefficients from EN12975.
The equation used to calculate solar gain is a modified version of Eq 559 from the EnergyPlus documentation. It is
QFlow[i] = Ac/nSeg FR(τα) (K (τα),Beam GBeam (1-shaCoe)+KDiff G Diff),
where QFlow[i] is the heat gained in each segment, A
c is the area of the collector, nSeg
is the number of
segments in the collector, FR(τα) is the maximum
efficiency of the collector, K(τα),Beam is the
incidence angle modifier for beam radiation, GBeam is the
current beam radiation on the collector, shaCoe
is the shading
coefficient, KDiff is the incidence angle modifier for
diffuse radiation and GDiff is the diffuse
radiation striking the surface.
The solar radiation equation indicates that the collector is divided into
multiple segments. The number of segments used in the simulation is specified
using the parameter nSeg
. The area of an individual segment is
identified by dividing the collector area by the total number of segments. The
parameter shaCoe
is used to define the percentage of the collector
which is shaded. The main difference between this model and the ASHRAE model
is the handling of diffuse radiation. The ASHRAE model contains calculated
incidence angle modifiers for both sky and ground diffuse radiation
while this model uses a coefficient from test data for diffuse radiation.
The incidence angle modifier for beam radiation is calculated using Eq 555 from the EnergyPlus documentation, as
K(τα),Beam=1+b0 (1/cos(θ)-1)+b1 (1/cos(θ)-1)2,
where K(τα),Beam is the incidence angle modifier for beam radiation, b0 is the first incidence angle modifier coefficient, θ is the incidence angle and b1 is the second incidence angle modifier coefficient.
This model reduces the heat gain rate to 0 W when the fluid temperature is within 1 degree C of the maximum temperature of the medium model. The calculation is performed using the Buildings.Utilities.Math.Functions.smoothHeaviside function.
References
EnergyPlus 7.0.0 Engineering Reference,
October 13, 2011.
CEN 2006, European Standard 12975-1:2006, European Committee for Standardization
Extends from Modelica.Blocks.Icons.Block (Basic graphical layout of input/output block), SolarCollectors.BaseClasses.PartialParameters (Partial model for parameters).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Area | A_c | Area of the collector [m2] | |
Integer | nSeg | 3 | Number of segments |
Real | y_intercept | Y intercept (Maximum efficiency) | |
replaceable package Medium | Modelica.Media.Interfaces.Pa... | Medium in the system | |
Real | B0 | 1st incident angle modifer coefficient | |
Real | B1 | 2nd incident angle modifer coefficient | |
Real | iamDiff | Incidence angle modifier for diffuse radiation | |
Shading | |||
Boolean | use_shaCoe_in | false | Enables an input connector for shaCoe |
Real | shaCoe | 0 | Shading coefficient 0.0: no shading, 1.0: full shading |
Connectors
Type | Name | Description |
---|---|---|
replaceable package Medium | Medium in the system | |
input RealInput | shaCoe_in | Time varying input for the shading coefficient |
input RealInput | HSkyDifTil | Diffuse solar irradiation on a tilted surfce from the sky [W/m2] |
input RealInput | incAng | Incidence angle of the sun beam on a tilted surface [rad] |
input RealInput | HDirTil | Direct solar irradiation on a tilted surfce [W/m2] |
output RealOutput | QSol_flow[nSeg] | Solar heat gain [W] |
input RealInput | TFlu[nSeg] | [K] |
Modelica definition
Buildings.Fluid.SolarCollectors.BaseClasses.IAM
Function for incident angle modifer
Information
Overview
This function computes the incidence angle modifier for solar insolation striking the surface of the solar thermal collector. It is calculated using Eq 555 in the EnergyPlus 7.0.0 Engineering Reference.
Notice
As stated in EnergyPlus7.0.0 the incidence angle equation performs poorly at angles greater than 60 degrees. This model outputs 0 whenever the incidence angle is greater than 60 degrees.
References
EnergyPlus 7.0.0 Engineering Reference, October 13, 2011.
Inputs
Type | Name | Default | Description |
---|---|---|---|
Angle | incAng | Incident angle [rad] | |
Real | B0 | 1st incident angle modifer coefficient | |
Real | B1 | 2nd incident angle modifer coefficient |
Outputs
Type | Name | Description |
---|---|---|
Real | incAngMod | Incident angle modifier coefficient |
Modelica definition
Buildings.Fluid.SolarCollectors.BaseClasses.PartialHeatLoss
Partial heat loss model on which ASHRAEHeatLoss and EN12975HeatLoss are based
Information
This component is a partial model used as the base for Buildings.Fluid.SolarCollectors.BaseClasses.ASHRAEHeatLoss and Buildings.Fluid.SolarCollectors.BaseClasses.EN12975HeatLoss. It contains the input, output and parameter declarations which are common to both models. More detailed information is available in the documentation for the extending classes.
Extends from Modelica.Blocks.Icons.Block (Basic graphical layout of input/output block), SolarCollectors.BaseClasses.PartialParameters (Partial model for parameters).
Parameters
Type | Name | Default | Description |
---|---|---|---|
Area | A_c | Area of the collector [m2] | |
Integer | nSeg | 3 | Number of segments |
Real | y_intercept | Y intercept (Maximum efficiency) | |
replaceable package Medium | Modelica.Media.Interfaces.Pa... | Medium in the component | |
SpecificHeatCapacity | cp_default | Specific heat capacity of the fluid at the default temperature [J/(kg.K)] | |
HeatFlowRate | QLos_nominal | Heat loss at nominal conditions, negative if heat flows from collector to environment [W] | |
Nominal condition | |||
Irradiance | G_nominal | Irradiance at nominal conditions [W/m2] | |
TemperatureDifference | dT_nominal | Ambient temperature minus fluid temperature at nominal conditions [K] | |
MassFlowRate | m_flow_nominal | Fluid flow rate at nominal conditions [kg/s] |
Connectors
Type | Name | Description |
---|---|---|
replaceable package Medium | Medium in the component | |
input RealInput | TEnv | Temperature of surrounding environment [K] |
input RealInput | TFlu[nSeg] | Temperature of the heat transfer fluid [K] |
output RealOutput | QLos[nSeg] | Limited heat loss rate at current conditions [W] |
Modelica definition
Buildings.Fluid.SolarCollectors.BaseClasses.PartialParameters
Partial model for parameters
Information
Partial parameters used in all solar collector models
Parameters
Type | Name | Default | Description |
---|---|---|---|
Area | A_c | Area of the collector [m2] | |
Integer | nSeg | 3 | Number of segments |
Real | y_intercept | Y intercept (Maximum efficiency) |
Modelica definition
Buildings.Fluid.SolarCollectors.BaseClasses.PartialSolarCollector
Partial model for solar collectors
Information
This component is a partial model of a solar thermal collector. It can be expanded to create solar collector models based on either ASHRAE93 or EN12975 ratings data.
Notice
As mentioned in the reference, the SRCC incident angle modifier equation coefficients are only valid for incident angles of 60 degrees or less. Because these curves behave poorly for angles greater than 60 degrees the model does not calculatue either direct or diffuse solar radiation gains when the incidence angle is greater than 60 degrees.
The heat capacity of the collector without fluid is
estimated based on the dry mass and the specific heat capacity of copper.
This heat capacity is then added to the model by increasing the size of the fluid
volume. Note that in earlier implementations, there was a separate model to take into
account this heat capacity. However, this led to a translation error if glycol
was used as the medium, because during the translation, the function T_ph
for
Modelica.Media.Incompressible.Examples.Glycol47 had to be differentiated,
but this function is not differentiable.
References
EnergyPlus 7.0.0 Engineering Reference,
October 13, 2011.
CEN 2006, European Standard 12975-1:2006, European Committee for Standardization
Extends from Buildings.Fluid.Interfaces.LumpedVolumeDeclarations (Declarations for lumped volumes), Buildings.Fluid.Interfaces.TwoPortFlowResistanceParameters (Parameters for flow resistance for models with two ports), Buildings.Fluid.Interfaces.PartialTwoPortInterface (Partial model transporting fluid between two ports without storing mass or energy).
Parameters
Type | Name | Default | Description |
---|---|---|---|
replaceable package Medium | PartialMedium | Medium in the component | |
Integer | nSeg | 3 | Number of segments used to discretize the collector model |
Angle | azi | Surface azimuth (0 for south-facing; -90 degree for east-facing; +90 degree for west facing [rad] | |
Angle | til | Surface tilt (0 for horizontally mounted collector) [rad] | |
Real | rho | Ground reflectance [1] | |
HeatCapacity | C | 385*perPar.mDry | Heat capacity of solar collector without fluid (default: cp_copper*mDry*nPanels) [J/K] |
Nominal condition | |||
PressureDifference | dp_nominal | dp_nominal_final | Pressure difference [Pa] |
MassFlowRate | m_flow_nominal | m_flow_nominal_final | Nominal mass flow rate [kg/s] |
Shading | |||
Boolean | use_shaCoe_in | false | Enables an input connector for shaCoe |
Real | shaCoe | 0 | Shading coefficient. 0.0: no shading, 1.0: full shading |
Area declarations | |||
NumberSelection | nColType | Buildings.Fluid.SolarCollect... | Selection of area specification format |
Integer | nPanels | 0 | Desired number of panels in the simulation |
Area | totalArea | 0 | Total area of panels in the simulation [m2] |
Configuration declarations | |||
SystemConfiguration | sysConfig | Buildings.Fluid.SolarCollect... | Selection of system configuration |
Dynamics | |||
Conservation equations | |||
Dynamics | energyDynamics | Modelica.Fluid.Types.Dynamic... | Type of energy balance: dynamic (3 initialization options) or steady state |
Real | mSenFac | 1 | Factor for scaling the sensible thermal mass of the volume |
Advanced | |||
Dynamics | |||
Dynamics | massDynamics | energyDynamics | Type of mass balance: dynamic (3 initialization options) or steady state, must be steady state if energyDynamics is steady state |
MassFlowRate | m_flow_small | 1E-4*abs(m_flow_nominal) | Small mass flow rate for regularization of zero flow [kg/s] |
Diagnostics | |||
Boolean | show_T | false | = true, if actual temperature at port is computed |
Initialization | |||
AbsolutePressure | p_start | Medium.p_default | Start value of pressure [Pa] |
Temperature | T_start | Medium.T_default | Start value of temperature [K] |
MassFraction | X_start[Medium.nX] | Medium.X_default | Start value of mass fractions m_i/m [kg/kg] |
ExtraProperty | C_start[Medium.nC] | fill(0, Medium.nC) | Start value of trace substances |
ExtraProperty | C_nominal[Medium.nC] | fill(1E-2, Medium.nC) | Nominal value of trace substances. (Set to typical order of magnitude.) |
Flow resistance | |||
Boolean | computeFlowResistance | true | =true, compute flow resistance. Set to false to assume no friction |
Boolean | from_dp | false | = true, use m_flow = f(dp) else dp = f(m_flow) |
Boolean | linearizeFlowResistance | false | = true, use linear relation between m_flow and dp for any flow rate |
Real | deltaM | 0.1 | Fraction of nominal flow rate where flow transitions to laminar |
Assumptions | |||
Boolean | allowFlowReversal | true | = false to simplify equations, assuming, but not enforcing, no flow reversal |
Connectors
Type | Name | Description |
---|---|---|
FluidPort_a | port_a | Fluid connector a (positive design flow direction is from port_a to port_b) |
FluidPort_b | port_b | Fluid connector b (positive design flow direction is from port_a to port_b) |
input RealInput | shaCoe_in | Shading coefficient |
Bus | weaBus | Weather data bus |