LBL logo

Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate

Package with SRCC rating information for glazed flat-plate solar thermal collectors

Information

Package with records for SRCC rating information for glazed flat-plate solar thermal collector. All models in the GlazedFlatPlate package are tested according to the ASHRAE93 standard.

Extends from Modelica.Icons.MaterialPropertiesPackage (Icon for package containing property classes).

Package Content

NameDescription
Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_GuangdongFSPTY95 FP_GuangdongFSPTY95 FP - Guandong Fivestar Solar Energy Co, FS-PTY95-2.0
Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_SolahartKf FP_SolahartKf FP - Solahart Kf
Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_ThermaLiteHS20 FP_ThermaLiteHS20 FP - Therma-Lite, HS-20
Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_TRNSYSValidation FP_TRNSYSValidation Default values in the TRNSYS Simulation Studio SDHW example

Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_GuangdongFSPTY95

FP - Guandong Fivestar Solar Energy Co, FS-PTY95-2.0

Information

References

Ratings data taken from the Solar Rating and Certification Corporation website. SRCC# = 2012043A.

Extends from SolarCollectors.Data.GenericSolarCollector (Generic data record providing inputs for specific collector data records).

Parameters

TypeNameDefaultDescription
AreaATypTypes.Area.GrossGross or aperture area
AreaA2Area [m2]
MassmDry35Dry weight [kg]
VolumeV1.7/1000Fluid volume [m3]
Pressuredp_nominal235Pressure drop during test conditions [Pa]
RealmperA_flow_nominal0.02Mass flow rate per unit area of collector [kg/(s.m2)]
RealB0-0.21651st incident angle modifier coefficient
RealB10.0232nd incident angle modifier coefficient
Realy_intercept0.678Y intercept (Maximum efficiency)
Realslope-4.426Slope from rating data [W/(m2.K)]
RealIAMDiff0Incidence angle modifier from EN12975 ratings data
RealC10Heat loss coefficient from EN12975 ratings data
RealC20Temperature dependence of heat loss from EN12975 ratings data
IrradianceG_nominal1000Nominal solar irradiance specified in ratings data [W/m2]
TemperatureDifferencedT_nominal10Nominal temperature difference specified in ratings data [K]

Modelica definition

record FP_GuangdongFSPTY95 =
    SolarCollectors.Data.GenericSolarCollector (
    final ATyp=Types.Area.Gross,
    final A=2,
    final mDry=35,
    final V=1.7/1000,
    final dp_nominal=235,
    final mperA_flow_nominal=0.02,
    final B0=-0.2165,
    final B1=0.023,
    final y_intercept=0.678,
    final slope=-4.426,
    final IAMDiff=0,
    final C1=0,
    final C2=0,
    final G_nominal = 1000,
    final dT_nominal = 10) 
  "FP - Guandong Fivestar Solar Energy Co, FS-PTY95-2.0";

Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_SolahartKf

FP - Solahart Kf

Information

References

Ratings data taken from the Solar Rating and Certification Corporation website. SRCC# = 2012021A.

Extends from SolarCollectors.Data.GenericSolarCollector (Generic data record providing inputs for specific collector data records).

Parameters

TypeNameDefaultDescription
AreaATypTypes.Area.GrossGross or aperture area
AreaA2.003Area [m2]
MassmDry42Dry weight [kg]
VolumeV3.8/1000Fluid volume [m3]
Pressuredp_nominal93.89Pressure drop during test conditions [Pa]
RealmperA_flow_nominal0.0194Mass flow rate per unit area of collector [kg/(s.m2)]
RealB0-0.1371st incident angle modifier coefficient
RealB10.01662nd incident angle modifier coefficient
Realy_intercept0.775Y intercept (Maximum efficiency)
Realslope-5.103Slope from rating data [W/(m2.K)]
RealIAMDiff0Incidence angle modifier from EN12975 ratings data
RealC10Heat loss coefficient from EN12975 ratings data
RealC20Temperature dependence of heat loss from EN12975 ratings data
IrradianceG_nominal1000Nominal solar irradiance specified in ratings data [W/m2]
TemperatureDifferencedT_nominal10Nominal temperature difference specified in ratings data [K]

Modelica definition

record FP_SolahartKf =
    SolarCollectors.Data.GenericSolarCollector (
    final ATyp=Types.Area.Gross,
    final A=2.003,
    final mDry=42,
    final V=3.8/1000,
    final dp_nominal=93.89,
    final mperA_flow_nominal=0.0194,
    final B0=-0.137,
    final B1=0.0166,
    final y_intercept=0.775,
    final slope=-5.103,
    final IAMDiff=0,
    final C1=0,
    final C2=0,
    final G_nominal=1000,
    final dT_nominal=10) "FP - Solahart Kf";

Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_ThermaLiteHS20

FP - Therma-Lite, HS-20

Information

References

Ratings data taken from the Solar Rating and Certification Corporation website. SRCC# = 2012047A.

Extends from SolarCollectors.Data.GenericSolarCollector (Generic data record providing inputs for specific collector data records).

Parameters

TypeNameDefaultDescription
AreaATypTypes.Area.GrossGross or aperture area
AreaA1.97Area [m2]
MassmDry26Dry weight [kg]
VolumeV2.8/1000Fluid volume [m3]
Pressuredp_nominal242.65Pressure drop during test conditions [Pa]
RealmperA_flow_nominal0.1777Mass flow rate per unit area of collector [kg/(s.m2)]
RealB0-0.06931st incident angle modifier coefficient
RealB1-0.23722nd incident angle modifier coefficient
Realy_intercept0.762Y intercept (Maximum efficiency)
Realslope-3.710Slope from rating data [W/(m2.K)]
RealIAMDiff0Incidence angle modifier from EN12975 ratings data
RealC10Heat loss coefficient from EN12975 ratings data
RealC20Temperature dependence of heat loss from EN12975 ratings data
IrradianceG_nominal1000Nominal solar irradiance specified in ratings data [W/m2]
TemperatureDifferencedT_nominal10Nominal temperature difference specified in ratings data [K]

Modelica definition

record FP_ThermaLiteHS20 =
    SolarCollectors.Data.GenericSolarCollector (
    final ATyp=Types.Area.Gross,
    final A=1.97,
    final mDry=26,
    final V=2.8/1000,
    final dp_nominal=242.65,
    final mperA_flow_nominal=0.1777,
    final B0=-0.0693,
    final B1=-0.2372,
    final y_intercept=0.762,
    final slope=-3.710,
    final IAMDiff=0,
    final C1=0,
    final C2=0,
    final G_nominal = 1000,
    final dT_nominal = 10) "FP - Therma-Lite, HS-20";

Buildings.Fluid.SolarCollectors.Data.GlazedFlatPlate.FP_TRNSYSValidation

Default values in the TRNSYS Simulation Studio SDHW example

Information

Default values in the TRNSYS Simualtion Studio SDHW example. No value for dp_nominal was provided in TRNSYS, so 1000 was used as a placeholder.

Extends from SolarCollectors.Data.GenericSolarCollector (Generic data record providing inputs for specific collector data records).

Parameters

TypeNameDefaultDescription
AreaATypTypes.Area.GrossGross or aperture area
AreaA5Area [m2]
MassmDry8.6Dry weight [kg]
VolumeV0.6/1000Fluid volume [m3]
Pressuredp_nominal100Pressure drop during test conditions [Pa]
RealmperA_flow_nominal0.0111Mass flow rate per unit area of collector [kg/(s.m2)]
RealB0-0.21st incident angle modifier coefficient
RealB1-02nd incident angle modifier coefficient
Realy_intercept0.8Y intercept (Maximum efficiency)
Realslope-3.6111Slope from rating data [W/(m2.K)]
RealIAMDiff0Incidence angle modifier from EN12975 ratings data
RealC10Heat loss coefficient from EN12975 ratings data
RealC20Temperature dependence of heat loss from EN12975 ratings data
IrradianceG_nominal800Nominal solar irradiance specified in ratings data [W/m2]
TemperatureDifferencedT_nominal10Nominal temperature difference specified in ratings data [K]

Modelica definition

record FP_TRNSYSValidation =
    SolarCollectors.Data.GenericSolarCollector (
    ATyp=Types.Area.Gross,
    A=5,
    mDry=8.6,
    V=0.6/1000,
    dp_nominal=100,
    mperA_flow_nominal=0.0111,
    B0=-0.2,
    B1=-0,
    y_intercept=0.8,
    slope=-3.6111,
    IAMDiff=0,
    C1=0,
    C2=0,
    G_nominal=800,
    dT_nominal=10) 
  "Default values in the TRNSYS Simulation Studio SDHW example";

Automatically generated Wed Feb 12 08:16:59 2014.