LBL logo

Buildings.HeatTransfer.Conduction.BaseClasses.Examples

Collection of models that illustrate model use and test models

Information

This package contains examples for the use of models that can be found in Buildings.HeatTransfer.Conduction.BaseClasses.

Extends from Modelica.Icons.ExamplesPackage (Icon for packages containing runnable examples).

Package Content

NameDescription
Buildings.HeatTransfer.Conduction.BaseClasses.Examples.Temperature_u Temperature_u Approximation of specific internal energy versus temperature curve with cubic hermite cubic spline

Buildings.HeatTransfer.Conduction.BaseClasses.Examples.Temperature_u Buildings.HeatTransfer.Conduction.BaseClasses.Examples.Temperature_u

Approximation of specific internal energy versus temperature curve with cubic hermite cubic spline

Information

This example tests and demonstrates the implementation of the specific internal energy versus temperature T(u) relationship for phase-change problems. Cubic hermite interpolation and linear extrapolation is used to approximate the piece-wise linear T(u) relationship. A piece-wise linear T(u) relationship is assumed in all three chracteristic regions (solid, mushy and liquid). The example uses the functions Buildings.HeatTransfer.Conduction.BaseClasses.der_temperature_u and Buildings.HeatTransfer.Conduction.BaseClasses.temeprature_u. The first function is used to compute the derivatives at the support points, and the second function computes the temperature for a given specific internal energy.

The example also demonstrates the use of cubic hermite spline interpolation with two different settings: One produces an approximation of the T(u) relationship that is monotone, whereas the other does not enforce monotonicity. The latter one is used by default in the Buildings library, since it produces a higher accuracy in the mushy region, especially for materials in which phase-change transformation occurs in a wide temperature interval (see the figure below). The curves errNonMonotone and errMonotone represent the relative error between approximated and exact temperatures obtained for different specific internal energy values (right hand side figure).

image

Extends from Modelica.Icons.Example (Icon for runnable examples).

Parameters

TypeNameDefaultDescription
GenericmaterialMonotone Phase change material with monotone u-T relation
GenericmaterialNonMonotone Phase change material with non-monotone u-T relation
SpecificInternalEnergyud[Buildings.HeatTransfer.Conduction.nSupPCM] Support points [J/kg]
TemperatureTd[Buildings.HeatTransfer.Conduction.nSupPCM] Support points [K]
Realscale0.999Scale used to position the points 1,3,4 and 6 while T2=TSol and T5=TLiq
RealdT_du[Buildings.HeatTransfer.Conduction.nSupPCM] Derivatives at the support points - non-monotone, default in Modelica PCM [kg.K2/J]
RealdT_duMonotone[Buildings.HeatTransfer.Conduction.nSupPCM] Derivatives at the support points for monotone increasing cubic splines [kg.K2/J]
TemperatureDifferencedTChamaterialMonotone.TSol + mate...Characteristic temperature difference of the problem [K]

Modelica definition

model Temperature_u 
  "Approximation of specific internal energy versus temperature curve with cubic hermite cubic spline"
  extends Modelica.Icons.Example;
  // Phase-change properties
  parameter Buildings.HeatTransfer.Data.SolidsPCM.Generic
      materialMonotone(
               TSol=273.15+30.9,
               TLiq=273.15+40.0,
               LHea=1000000,
               c=920,
               ensureMonotonicity=true,
               d=1000,
               k=1,
               x=0.2) "Phase change material with monotone u-T relation";
  parameter Buildings.HeatTransfer.Data.SolidsPCM.Generic
      materialNonMonotone(TSol=273.15+30.9,
               TLiq=273.15+40.0,
               LHea=1000000,
               c=920,
               ensureMonotonicity=false,
               d=1000,
               k=1,
               x=0.2) "Phase change material with non-monotone u-T relation";
  parameter Modelica.SIunits.SpecificInternalEnergy ud[Buildings.HeatTransfer.Conduction.nSupPCM](each fixed=false) 
    "Support points";
  parameter Modelica.SIunits.Temperature Td[Buildings.HeatTransfer.Conduction.nSupPCM](each fixed=false) 
    "Support points";
  parameter Real scale=0.999 
    "Scale used to position the points 1,3,4 and 6 while T2=TSol and T5=TLiq";
  parameter Real dT_du[Buildings.HeatTransfer.Conduction.nSupPCM](each fixed=false, each unit="kg.K2/J") 
    "Derivatives at the support points - non-monotone, default in Modelica PCM";
  parameter Real[Buildings.HeatTransfer.Conduction.nSupPCM] dT_duMonotone(each fixed=false, each unit="kg.K2/J") 
    "Derivatives at the support points for monotone increasing cubic splines";
  Modelica.SIunits.SpecificInternalEnergy u "Specific internal energy";
  Modelica.SIunits.Temperature T 
    "Temperature for given u without monotone interpolation";
  Modelica.SIunits.Temperature TMonotone 
    "Temperature for given u with monotone interpolation";
  Modelica.SIunits.Temperature TExa "Exact value of temperature";
  Real errMonotone 
    "Relative temperature error between calculated value with monotone interpolation and exact temperature";
  Real errNonMonotone 
    "Relative temperature error between calculated value with non-monotone interpolation and exact temperature";

 parameter Modelica.SIunits.TemperatureDifference dTCha = materialMonotone.TSol+materialMonotone.TLiq 
    "Characteristic temperature difference of the problem";
protected 
  function relativeError "Relative error"
    input Modelica.SIunits.Temperature T "Approximated temperature";
    input Modelica.SIunits.Temperature TExa "Exact temperature";
    input Modelica.SIunits.TemperatureDifference dTCha 
      "Characteristic temperature difference";
    output Real relErr "Relative error";
  algorithm 
    relErr :=(T - TExa)/dTCha;
  end relativeError;

  constant Real conFac(unit="1/s") = 1 
    "Conversion factor to satisfy unit check";
initial algorithm 
  // Calculate derivatives at support points (non-monotone)
  (ud, Td, dT_du) :=
    Buildings.HeatTransfer.Conduction.BaseClasses.der_temperature_u(
    materialNonMonotone);
  // Calculate derivatives at support points (monotone);
 (ud, Td, dT_duMonotone) :=
    Buildings.HeatTransfer.Conduction.BaseClasses.der_temperature_u(
    materialMonotone);
algorithm 
  u :=  2.5e5+time*(1.5*materialMonotone.c*(materialMonotone.TLiq-273.15)+materialMonotone.LHea)*conFac;

  // Calculate T based on non-monotone interpolation
  T := Buildings.HeatTransfer.Conduction.BaseClasses.temperature_u(
       ud=ud,
       Td=Td,
       dT_du=dT_du,
       u=u);
  // Calculate T based on monotone interpolation
  TMonotone := Buildings.HeatTransfer.Conduction.BaseClasses.temperature_u(
       ud=ud,
       Td=Td,
       dT_du=dT_duMonotone,
       u=u);
  //Relative errors of obtained temperatures by using monotone and non-monotone
  //interpolation against exact values of tempratures taken from the T(u) curve
  if time>=1.e-05 then
    if u <= materialMonotone.c*materialMonotone.TSol then
      // Solid region
      TExa           := u/materialMonotone.c;
    elseif u >= materialMonotone.c*materialMonotone.TLiq+materialMonotone.LHea then
      // Liquid region
      TExa           := (u-materialMonotone.LHea)/materialMonotone.c;
   else
      // Region of phase transition
      TExa:=((u + materialMonotone.LHea*materialMonotone.TSol/(materialMonotone.TLiq
         - materialMonotone.TSol))/(materialMonotone.c + materialMonotone.LHea/(
        materialMonotone.TLiq - materialMonotone.TSol)));
    end if;
  else
    TExa :=T;
  end if;
  errNonMonotone := relativeError(T=T,         TExa=TExa, dTCha=  dTCha);
  errMonotone    := relativeError(T=TMonotone, TExa=TExa, dTCha=  dTCha);

end Temperature_u;