Package with performance data for solar thermal collectors. All solar collector data package names begin with an abbreviation of the type of collector it is. The abbreviations are as follows:
Name | Description |
---|---|
Concentrating | Package with SRCC rating information for concentrating solar thermal collectors |
GlazedFlatPlate | Package with SRCC rating information for glazed flat-plate solar thermal collectors |
Tubular | Package with SRCC rating information for tubular solar thermal collectors |
GenericSolarCollector | Generic data record providing inputs for specific collector data records |
Generic data file which is used for the Buildings.Fluid.Solarcollectors.BaseClasses.PartialSolarCollector model. Establishes the base inputs needed to create model-specific data packages.
Type | Name | Default | Description |
---|---|---|---|
Area | ATyp | Gross or aperture area | |
Area | A | Area [m2] | |
Mass | mDry | Dry weight [kg] | |
Volume | V | Fluid volume [m3] | |
Pressure | dp_nominal | Pressure drop during test conditions [Pa] | |
Real | mperA_flow_nominal | Mass flow rate per unit area of collector [kg/(s.m2)] | |
Real | B0 | 1st incident angle modifier coefficient | |
Real | B1 | 2nd incident angle modifier coefficient | |
Real | y_intercept | Y intercept (Maximum efficiency) | |
Real | slope | Slope from rating data [W/(m2.K)] | |
Real | IAMDiff | Incidence angle modifier from EN12975 ratings data | |
Real | C1 | Heat loss coefficient from EN12975 ratings data | |
Real | C2 | Temperature dependence of heat loss from EN12975 ratings data | |
Irradiance | G_nominal | Nominal solar irradiance specified in ratings data [W/m2] | |
TemperatureDifference | dT_nominal | Nominal temperature difference specified in ratings data [K] |
record GenericSolarCollector "Generic data record providing inputs for specific collector data records" parameter SolarCollectors.Types.Area ATyp "Gross or aperture area"; parameter Modelica.SIunits.Area A "Area"; parameter Modelica.SIunits.Mass mDry "Dry weight"; parameter Modelica.SIunits.Volume V "Fluid volume"; parameter Modelica.SIunits.Pressure dp_nominal "Pressure drop during test conditions"; parameter Real mperA_flow_nominal(unit="kg/(s.m2)") "Mass flow rate per unit area of collector"; parameter Real B0 "1st incident angle modifier coefficient"; parameter Real B1 "2nd incident angle modifier coefficient"; parameter Real y_intercept "Y intercept (Maximum efficiency)"; parameter Real slope(unit = "W/(m2.K)") "Slope from rating data"; parameter Real IAMDiff "Incidence angle modifier from EN12975 ratings data"; parameter Real C1 "Heat loss coefficient from EN12975 ratings data"; parameter Real C2 "Temperature dependence of heat loss from EN12975 ratings data"; parameter Modelica.SIunits.Irradiance G_nominal "Nominal solar irradiance specified in ratings data"; parameter Modelica.SIunits.TemperatureDifference dT_nominal "Nominal temperature difference specified in ratings data";end GenericSolarCollector;