Buildings.ThermalZones.ISO13790.Validation.BESTEST.Data
Data records for BESTEST validation
Information
This package contains data records for the BESTEST validation.
Extends from Modelica.Icons.MaterialPropertiesPackage (Icon for package containing property classes).
Package Content
| Name | Description | 
|---|---|
|  Case600FFResults | BESTEST comparison results free-floating | 
|  Case600Mass | BESTEST600 | 
|  Case600Results | BESTEST comparison results | 
|  Case900Mass | BESTEST900 | 
 Buildings.ThermalZones.ISO13790.Validation.BESTEST.Data.Case600FFResults
Buildings.ThermalZones.ISO13790.Validation.BESTEST.Data.Case600FFResults
BESTEST comparison results free-floating
Information
BESTEST results for annual heating and cooling loads in free-floating mode.
Extends from Modelica.Icons.Record (Icon for records).
Contents
| Type | Name | Default | Description | 
|---|---|---|---|
| Temperature | TavgMax | 299.05 | Maximum average annual air temperature [K] | 
| Temperature | TavgMin | 297.35 | Minimum average annual air temperature [K] | 
Modelica definition
 Buildings.ThermalZones.ISO13790.Validation.BESTEST.Data.Case600Mass
Buildings.ThermalZones.ISO13790.Validation.BESTEST.Data.Case600Mass
BESTEST600
Information
Thermal mass for Case600Mass.
Extends from Buildings.ThermalZones.ISO13790.Data.Generic (Generic data record for building thermal mass).
Contents
| Type | Name | Default | Description | 
|---|---|---|---|
| Thermal mass | |||
| Real | heaC | 42167 | Heat capacity per unit area of the floor [J/(K.m2)] | 
| Real | facMas | 2.95 | Effective mass area factor [1] | 
Modelica definition
 Buildings.ThermalZones.ISO13790.Validation.BESTEST.Data.Case600Results
Buildings.ThermalZones.ISO13790.Validation.BESTEST.Data.Case600Results
BESTEST comparison results
Information
BESTEST results for annual heating and cooling loads.
Extends from Modelica.Icons.Record (Icon for records).
Contents
| Type | Name | Default | Description | 
|---|---|---|---|
| Energy | EHeaMax | 20.5524E+09 | Maximum annual heating load [J] | 
| Energy | EHeaMin | 15.4656E+09 | Minimum annaul heating load [J] | 
| Energy | ECooMax | -26.2008E+09 | Maximum annual cooling load [J] | 
| Energy | ECooMin | -22.0932E+09 | Minimum annual cooling load [J] | 
| Power | PHeaMax | 4354 | Maximum peak heating load [W] | 
| Power | PHeaMin | 3437 | Minimum peak heating load [W] | 
| Power | PCooMax | -6827 | Maximum peak cooling load [W] | 
| Power | PCooMin | -5965 | Minimum peak cooling load [W] | 
Modelica definition
 Buildings.ThermalZones.ISO13790.Validation.BESTEST.Data.Case900Mass
Buildings.ThermalZones.ISO13790.Validation.BESTEST.Data.Case900Mass
BESTEST900
Information
Thermal mass for Case900Mass.
Extends from Buildings.ThermalZones.ISO13790.Data.Generic (Generic data record for building thermal mass).
Contents
| Type | Name | Default | Description | 
|---|---|---|---|
| Thermal mass | |||
| Real | heaC | 307750 | Heat capacity per unit area of the floor [J/(K.m2)] | 
| Real | facMas | 2.43 | Effective mass area factor [1] | 