Buildings.Fluid.DataCenters.Racks.Liquid.Data

Package with data records for racks

Information

This package contains data records for models of the package Buildings.Fluid.DataCenters.Racks.

Extends from Modelica.Icons.MaterialPropertiesPackage (Icon for package containing property classes).

Package Content

Name Description
Buildings.Fluid.DataCenters.Racks.Liquid.Data.Generic Generic Generic data record for liquid-cooled single-phase rack
Buildings.Fluid.DataCenters.Racks.Liquid.Data.OCP_1kW_OAM_PG25 OCP_1kW_OAM_PG25 OpenCompute example for 1 kW OAM with PG25 as working fluid
Buildings.Fluid.DataCenters.Racks.Liquid.Data.OCP_1kW_OAM_Water OCP_1kW_OAM_Water OpenCompute example for 1 kW OAM with DI water as working fluid
Buildings.Fluid.DataCenters.Racks.Liquid.Data.BaseClasses BaseClasses Package with base classes for data records

Buildings.Fluid.DataCenters.Racks.Liquid.Data.Generic Buildings.Fluid.DataCenters.Racks.Liquid.Data.Generic

Generic data record for liquid-cooled single-phase rack

Buildings.Fluid.DataCenters.Racks.Liquid.Data.Generic

Information

Generic data record for a liquid-cooled single-phase IT rack.

Extends from Buildings.Fluid.DataCenters.Racks.BaseClasses.Data.Generic (Generic data record for IT rack).

Contents

TypeNameDefaultDescription
Generic_R_m_flowtheRes Thermal resistance data
Nominal condition
HeatFlowRatePIT_nominal IT power consumption at u=1, also called Thermal Design Power (TDP) [W]
MassFlowRatem_flow_nominal Nominal mass flow rate [kg/s]
PressureDifferencedp_nominal50000Pressure drop at nominal mass flow rate [Pa]
Flow resistance
Realn1.85Flow exponent, n=1 for laminar, n=2 for turbulent
RealdeltaM0.3Fraction of nominal mass flow rate where transition to turbulent occurs

Modelica definition

record Generic "Generic data record for liquid-cooled single-phase rack" extends Buildings.Fluid.DataCenters.Racks.BaseClasses.Data.Generic; // Flow resistance parameter Modelica.Units.SI.PressureDifference dp_nominal(displayUnit="Pa") = 50000 "Pressure drop at nominal mass flow rate"; parameter Real n(min=1, max=2) = 1.85 "Flow exponent, n=1 for laminar, n=2 for turbulent"; parameter Real deltaM(min=1E-6) = 0.3 "Fraction of nominal mass flow rate where transition to turbulent occurs"; parameter BaseClasses.Generic_R_m_flow theRes "Thermal resistance data"; end Generic;

Buildings.Fluid.DataCenters.Racks.Liquid.Data.OCP_1kW_OAM_PG25 Buildings.Fluid.DataCenters.Racks.Liquid.Data.OCP_1kW_OAM_PG25

OpenCompute example for 1 kW OAM with PG25 as working fluid

Buildings.Fluid.DataCenters.Racks.Liquid.Data.OCP_1kW_OAM_PG25

Information

This specification is for a 1 kW Open Accelerator Module (OAM) based on the Open Compute Project (OCP) report by Chen et al. (2023). The data is based on Figure 7, which is for a single cold plate with PG25 as the working fluid.

Note: The values for dp_nominal, n and deltaM are generic, as no data for these parameters were found.

References

Cheng Chen, Dennis Trieu, Tejas Shah, Allen Guo, Jaylen Cheng, Christopher Chapman, Sukhvinder Kang, Eran Dagan, Assaf Dinstag, Jane Yao. OCP OAI SYSTEM LIQUID COOLING GUIDELINES. 2023.

Extends from Buildings.Fluid.DataCenters.Racks.Liquid.Data.Generic (Generic data record for liquid-cooled single-phase rack).

Contents

TypeNameDefaultDescription
Nominal condition
HeatFlowRatePIT_nominal IT power consumption at u=1, also called Thermal Design Power (TDP) [W]
MassFlowRatem_flow_nominal Nominal mass flow rate [kg/s]
PressureDifferencedp_nominal50000Pressure drop at nominal mass flow rate [Pa]
Flow resistance
Realn1.85Flow exponent, n=1 for laminar, n=2 for turbulent
RealdeltaM0.3Fraction of nominal mass flow rate where transition to turbulent occurs

Modelica definition

record OCP_1kW_OAM_PG25 "OpenCompute example for 1 kW OAM with PG25 as working fluid" extends Buildings.Fluid.DataCenters.Racks.Liquid.Data.Generic( theRes( V_flow={0.4,0.5,0.6,0.7,0.8,0.9,1.0,1.2,1.4, 1.6,1.8,2.0,2.2,2.4}/60/1000, R={0.0389,0.0325,0.0300,0.0280,0.0265,0.0255, 0.0245,0.0230,0.0220,0.0214,0.0209,0.0204,0.0200,0.0197})); end OCP_1kW_OAM_PG25;

Buildings.Fluid.DataCenters.Racks.Liquid.Data.OCP_1kW_OAM_Water Buildings.Fluid.DataCenters.Racks.Liquid.Data.OCP_1kW_OAM_Water

OpenCompute example for 1 kW OAM with DI water as working fluid

Buildings.Fluid.DataCenters.Racks.Liquid.Data.OCP_1kW_OAM_Water

Information

This specification is for a 1 kW Open Accelerator Module (OAM) based on the Open Compute Project (OCP) report by Chen et al. (2023). The data is based on Figure 8, which is for a single cold plate with deionized (DI) water as the working fluid.

Note: The values for dp_nominal, n and deltaM are generic, as no data for these parameters were found.

References

Cheng Chen, Dennis Trieu, Tejas Shah, Allen Guo, Jaylen Cheng, Christopher Chapman, Sukhvinder Kang, Eran Dagan, Assaf Dinstag, Jane Yao. OCP OAI SYSTEM LIQUID COOLING GUIDELINES. 2023.

Extends from Buildings.Fluid.DataCenters.Racks.Liquid.Data.Generic (Generic data record for liquid-cooled single-phase rack).

Contents

TypeNameDefaultDescription
Nominal condition
HeatFlowRatePIT_nominal IT power consumption at u=1, also called Thermal Design Power (TDP) [W]
MassFlowRatem_flow_nominal Nominal mass flow rate [kg/s]
PressureDifferencedp_nominal50000Pressure drop at nominal mass flow rate [Pa]
Flow resistance
Realn1.85Flow exponent, n=1 for laminar, n=2 for turbulent
RealdeltaM0.3Fraction of nominal mass flow rate where transition to turbulent occurs

Modelica definition

record OCP_1kW_OAM_Water "OpenCompute example for 1 kW OAM with DI water as working fluid" extends Buildings.Fluid.DataCenters.Racks.Liquid.Data.Generic( theRes( V_flow={2.0,3.0,4.0,5.0}/60/1000, R={0.0172,0.0160,0.0154,0.0151}) ); end OCP_1kW_OAM_Water;