<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Tianzhen Hong</style></author><author><style face="normal" font="default" size="100%">Cheng Li</style></author><author><style face="normal" font="default" size="100%">Da Yan</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Updates to the China Design Standard for Energy Efficiency  in Public Buildings</style></title><secondary-title><style face="normal" font="default" size="100%">Energy Policy</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">building design</style></keyword><keyword><style  face="normal" font="default" size="100%">building energy standard</style></keyword><keyword><style  face="normal" font="default" size="100%">China</style></keyword><keyword><style  face="normal" font="default" size="100%">energy efficiency</style></keyword><keyword><style  face="normal" font="default" size="100%">GB 50189</style></keyword><keyword><style  face="normal" font="default" size="100%">Public buildings</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2015</style></year><pub-dates><date><style  face="normal" font="default" size="100%">12/2015</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">87</style></volume><pages><style face="normal" font="default" size="100%">187-198</style></pages><abstract><style face="normal" font="default" size="100%">&lt;p&gt;The China Design Standard for Energy Efficiency in public buildings (GB 50189) debuted in 2005 when China completed the 10th Five-Year Plan. GB 50189-2005 played a crucial role in regulating the energy efficiency in Chinese commercial buildings. The standard was recently updated in 2014 to increase energy savings targets by 30% compared with the 2005 standard. This paper reviews the major changes to the standard, including expansion of energy efficiency coverage and more stringent efficiency requirements. The paper also discusses the interrelationship of the design standard with China&#039;s other building energy standards. Furthermore, comparisons are made with ASHRAE Standard 90.1-2013 to provide contrasting differences in efficiency requirements. Finally recommendations are provided to guide the future standard revision, focusing on three areas: (1) increasing efficiency requirements of building envelope and HVAC systems, (2) adding a whole-building performance compliance pathway and implementing a ruleset based automatic code baseline model generation in an effort to reduce the discrepancies of baseline models created by different tools and users, and (3) adding inspection and commissioning requirements to ensure building equipment and systems are installed correctly and operate as designed.&lt;/p&gt;</style></abstract><custom2><style face="normal" font="default" size="100%">LBNL-1004493</style></custom2></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Liping Wang</style></author><author><style face="normal" font="default" size="100%">Paul A. Mathew</style></author><author><style face="normal" font="default" size="100%">Xiufeng Pang</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Uncertainties in energy consumption introduced by building operations and weather for a medium-size office building</style></title><secondary-title><style face="normal" font="default" size="100%">Energy and Buildings</style></secondary-title><short-title><style face="normal" font="default" size="100%">Energy and Buildings</style></short-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Building Operations</style></keyword><keyword><style  face="normal" font="default" size="100%">energyplus</style></keyword><keyword><style  face="normal" font="default" size="100%">Monte Carlo Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Uncertainties</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2012</style></year><pub-dates><date><style  face="normal" font="default" size="100%">10/2012</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">53</style></volume><pages><style face="normal" font="default" size="100%">152 - 158</style></pages><custom2><style face="normal" font="default" size="100%">LBNL-5888E</style></custom2></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Prajesh Bhattacharya</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Unlocking Historical Data in Critical IT</style></title><secondary-title><style face="normal" font="default" size="100%">Data Center Dynamics Focus</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">12/2008</style></date></pub-dates></dates><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Michael Wetter</style></author><author><style face="normal" font="default" size="100%">Philip Haves</style></author><author><style face="normal" font="default" size="100%">Michael A. Moshier</style></author><author><style face="normal" font="default" size="100%">Edward F. Sowell</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Using SPARK as a Solver for Modelica</style></title><secondary-title><style face="normal" font="default" size="100%">SimBuild 2008</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">07/2008</style></date></pub-dates></dates><pub-location><style face="normal" font="default" size="100%">Berkeley, CA, USA</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Michael Wetter</style></author><author><style face="normal" font="default" size="100%">Philip Haves</style></author><author><style face="normal" font="default" size="100%">Michael A. Moshier</style></author><author><style face="normal" font="default" size="100%">Edward F. Sowell</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Using SPARK as a solver for Modelica</style></title><secondary-title><style face="normal" font="default" size="100%">Proc. of the 3rd SimBuild Conference</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2008</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ibpsa.us/simbuild2008/technical_sessions/SB08-DOC-TS03-1-Wetter.pdf</style></url></web-urls></urls><pub-location><style face="normal" font="default" size="100%">Berkeley, CA, USA</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Modelica is an object-oriented acausal modeling language that is well positioned to become a de-facto standard for expressing models of complex physical systems.  To simulate a model expressed in Modelica, it needs to be translated into executable code. For generating run-time efficient code, such a translation needs to employ algebraic formula manipulations. As the SPARK solver has been shown to be competitive for generating such code but currently cannot be used with the Modelica language, we report in this paper how SPARK&#039;s symbolic and numerical algorithms can be implemented in OpenModelica, an open-source implementation of a Modelica modeling and simulation environment. We also report benchmark results that show that for our air flow network simulation benchmark, the SPARK solver is competitive with Dymola, which is believed to provide the best solver for Modelica.&lt;/p&gt;</style></abstract><custom2><style face="normal" font="default" size="100%">LBNL-634E</style></custom2></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">James O&#039;Donnell</style></author><author><style face="normal" font="default" size="100%">Marcus Keane</style></author><author><style face="normal" font="default" size="100%">Vladimir Bazjanac</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Utilisation of Whole Building Energy Simulation Output to Provide Optimum Decision Support for Building Managers</style></title><secondary-title><style face="normal" font="default" size="100%">SimBuild 2008</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2008</style></year></dates><pub-location><style face="normal" font="default" size="100%">Berkeley, CA</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Alberto Hernandez</style></author><author><style face="normal" font="default" size="100%">Flávio Neto</style></author><author><style face="normal" font="default" size="100%">Augusto Sanzovo Fiorelli</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Use of Simulation Tools for Managing Buildings Energy Demand</style></title><secondary-title><style face="normal" font="default" size="100%">Proc. Building Simulation 2007</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2007</style></year><pub-dates><date><style  face="normal" font="default" size="100%">09/2007</style></date></pub-dates></dates><pub-location><style face="normal" font="default" size="100%">Beijing, China</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Brian Ó Gallachóir</style></author><author><style face="normal" font="default" size="100%">Marcus Keane</style></author><author><style face="normal" font="default" size="100%">Elmer Morrissey</style></author><author><style face="normal" font="default" size="100%">James O&#039;Donnell</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Using Indicators to Profile Energy Consumption and Inform Energy Policy in a University - A Case Study in Ireland</style></title><secondary-title><style face="normal" font="default" size="100%">Energy and Buildings</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">building energy performance</style></keyword><keyword><style  face="normal" font="default" size="100%">Energy in services sector</style></keyword><keyword><style  face="normal" font="default" size="100%">energy policy</style></keyword><keyword><style  face="normal" font="default" size="100%">University</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2007</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2007</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">39</style></volume><pages><style face="normal" font="default" size="100%">913-922</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;The services sector has the least amount of energy end use data available, which poses significant challenges to companies within the sector attempting to benchmark their energy performance and inform energy management decisions. This paper explores through a case study analysis the use of simple performance indicators and how additional data and new metrics can greatly enhance the understanding of energy trends and in particular the assessment of building energy performance. The country chosen for the analysis is Ireland, where the services sector has experienced high energy demand growth since 1990 (4.1% annually) compared with the EU-15 (1.5% annually). Despite this growth, the available energy data is poor, in particular for the public service sub-sectors. The case study chosen is an institution within the education sub-sector, University College Cork. The paper presents some simple energy performance indicators that have been used to date to inform energy policy. The paper then introduces new approaches and tools for assessing energy performance in buildings and how these may be utilised to improve the energy policy decision making and energy management. It discusses how these approaches are been implemented for buildings with separate functions, presents some initial results and discusses future planned work.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">8</style></issue><section><style face="normal" font="default" size="100%">913</style></section></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Yu Joe Huang</style></author><author><style face="normal" font="default" size="100%">Norman Bourassa</style></author><author><style face="normal" font="default" size="100%">Walter F. Buhl</style></author><author><style face="normal" font="default" size="100%">Ender Erdem</style></author><author><style face="normal" font="default" size="100%">Robert J. Hitchcock</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Using EnergyPlus for California Title-24 Compliance Calculations</style></title><secondary-title><style face="normal" font="default" size="100%">SimBuild 2006</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2006</style></date></pub-dates></dates><pub-location><style face="normal" font="default" size="100%">Cambridge, MA, USA</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Yu Joe Huang</style></author><author><style face="normal" font="default" size="100%">Norman Bourassa</style></author><author><style face="normal" font="default" size="100%">Walter F. Buhl</style></author><author><style face="normal" font="default" size="100%">Ender Erdem</style></author><author><style face="normal" font="default" size="100%">Robert J. Hitchcock</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Using EnergyPlus for California Title-24 compliance calculations</style></title><secondary-title><style face="normal" font="default" size="100%">SimBuild 2006</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2006</style></date></pub-dates></dates><pub-location><style face="normal" font="default" size="100%">Cambridge, MA</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;For the past decade, the non-residential portion of California&#039;s Title-24 building energy standard has relied on &lt;em&gt;DOE-2.1E&lt;/em&gt; as the reference computer simulation program for development as well as compliance. However, starting in 2004, the California Energy Commission has been evaluating the possible use of EnergyPlus as the reference program in future revisions of Title-24. As part of this evaluation, the authors converted the Alternate Compliance Method (ACM) certification test suite of 150 &lt;em&gt;DOE-2&lt;/em&gt; files to &lt;em&gt;EnergyPlus&lt;/em&gt;, and made parallel &lt;em&gt;DOE-2&lt;/em&gt; and &lt;em&gt;EnergyPlus&lt;/em&gt; runs for this extensive set of test cases. A customized version of &lt;em&gt;DOE-2.1E&lt;/em&gt; named doe2ep was developed to automate the conversion process. This paper describes this conversion process, including the difficulties in establishing an apples-to-apples comparison between the two programs, and summarizes how the &lt;em&gt;DOE-2&lt;/em&gt; and &lt;em&gt;EnergyPlus&lt;/em&gt; results compare for the ACM test cases.&lt;/p&gt;</style></abstract><call-num><style face="normal" font="default" size="100%">LBNL-61527</style></call-num><custom1><style face="normal" font="default" size="100%">&lt;p&gt;Simulation Research Group&lt;/p&gt;</style></custom1><custom2><style face="normal" font="default" size="100%">LBNL-61527</style></custom2></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Zheng, B</style></author><author><style face="normal" font="default" size="100%">Xiufeng Pang</style></author><author><style face="normal" font="default" size="100%">Mingsheng Liu</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Using a Fan Air Flow Station to Control Building Static Pressure in a VAV System</style></title><secondary-title><style face="normal" font="default" size="100%">the 2005 International Solar Energy Conference</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2005</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2005</style></date></pub-dates></dates><pub-location><style face="normal" font="default" size="100%">Orlando, FL</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Wangda Zuo</style></author><author><style face="normal" font="default" size="100%">Tianyi Yang</style></author><author><style face="normal" font="default" size="100%">Wenyan Zou</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Updating traditional CRM system by terminal server</style></title><secondary-title><style face="normal" font="default" size="100%">Journal of Chongqing University (Natural Science Edition)</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2004</style></year></dates><volume><style face="normal" font="default" size="100%">27</style></volume><pages><style face="normal" font="default" size="100%">94-95</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><issue><style face="normal" font="default" size="100%">1</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Philip Haves</style></author><author><style face="normal" font="default" size="100%">Paul F. Linden</style></author><author><style face="normal" font="default" size="100%">Guilherme Carrilho da Graça</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Use of Simulation in the Design of a Large Naturally Ventilated Office Building</style></title><secondary-title><style face="normal" font="default" size="100%">Building Services Engineering Research &amp; Technology</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2004</style></year></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://bse.sagepub.com/content/25/3/211</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">25</style></volume><pages><style face="normal" font="default" size="100%">211-221</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">The design for the new Federal Building for San Francisco includes an office tower that is to be naturally ventilated. The EnergyPlus thermal simulation program was used to evaluate different ventilation strategies for space cooling and rationalize the design of the façade. The strategies include ventilation driven by different combinations of wind, internal stack and external stack. The simulation results indicate that wind-driven ventilation can maintain adequate comfort even during hot periods. Computational fluid dynamics was used to study the airflow and temperature distribution in the occupied spaces arising from different combinations of window openings and outside conditions and thereby inform both the design of the windows and the control strategy.</style></abstract><issue><style face="normal" font="default" size="100%">3</style></issue><custom2><style face="normal" font="default" size="100%">LBNL-56011</style></custom2></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Philip Haves</style></author><author><style face="normal" font="default" size="100%">Guilherme Carrilho da Graça</style></author><author><style face="normal" font="default" size="100%">Paul F. Linden</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Use of Simulation in the Design of a Large Naturally Ventilated Commercial Office Building</style></title><secondary-title><style face="normal" font="default" size="100%">Building Simulation ’03</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2003</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2003</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.inive.org/members_area/medias/pdf/Inive/IBPSA/UFSC912.pdf</style></url></web-urls></urls><pub-location><style face="normal" font="default" size="100%">Eindhoven, Netherlands</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language><custom2><style face="normal" font="default" size="100%">LBNL-56011</style></custom2></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Prajesh Bhattacharya</style></author><author><style face="normal" font="default" size="100%">Patrick E. Phelan</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Understanding the Behavior of an F1-ATPase Biomolecular Motor Using Brownian Dynamics Simulation</style></title><secondary-title><style face="normal" font="default" size="100%">US-Japan Nanotherm Seminar: Nanoscale Thermal Science and Engineering</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2002</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2002</style></date></pub-dates></dates><pub-location><style face="normal" font="default" size="100%">Berkeley, CA</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Philip Haves</style></author><author><style face="normal" font="default" size="100%">Tim I. Salsbury</style></author><author><style face="normal" font="default" size="100%">David Claridge</style></author><author><style face="normal" font="default" size="100%">Mingsheng Liu</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Use of Whole Building Simulation in On-Line Performance Assessment: Modeling and Implementation Issues</style></title><secondary-title><style face="normal" font="default" size="100%">Building Simulation ’01</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2001</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2001</style></date></pub-dates></dates><pub-location><style face="normal" font="default" size="100%">Rio de Janeiro</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;The application of model-based performance assessment at the whole building level is explored. The information requirements for a simulation to predict the actual performance of a particular real building, as opposed to estimating the impact of design options, are addressed with particular attention to common sources of input error and important deficiencies in most simulation models. The role of calibrated simulations is discussed. The communication requirements for passive monitoring and active testing are identified and the possibilities for using control system communications protocols to link on-line simulation and energy management and control systems are discussed. The potential of simulation programs to act as &quot;plug-and-play&quot; components on building control networks is discussed.&lt;/p&gt;</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Mary Ann Piette</style></author><author><style face="normal" font="default" size="100%">Satkartar T. Khalsa</style></author><author><style face="normal" font="default" size="100%">Philip Haves</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Use of an Information Monitoring and Diagnostic System for Commissioning and Ongoing Operations</style></title><secondary-title><style face="normal" font="default" size="100%">8th National Conference on Building Commissioning PECI</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2000</style></year><pub-dates><date><style  face="normal" font="default" size="100%">05/2000</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://imds.lbl.gov/pubs/paper383.pdf</style></url></web-urls></urls><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">This paper discusses a demonstration of a technology to address the problem that buildings do not perform as well as anticipated during design. We partnered with an innovative building operator to evaluate a prototype Information Monitoring and Diagnostic System (IMDS). The IMDS consists of a set of high-quality sensors, data acquisition software and hardware, and data visualization software, including a web-based remote access system that can be used to identify control problems and equipment faults. The IMDS allowed the operators to make more effective use of the control system, freeing up time to take care of other tenant needs. The operators report observing significant improvements in building comfort, potentially improving tenant health and productivity. Reduction in hours to operate the building are worth about $20,000 per year, which alone could pay for the IMDS in about five years. A control system retrofit based on findings from the IMDS is expected to reduce energy use by 20 percent over the next year, worth over $30,000 per year in energy cost savings. The operators recommend that similar technology be adopted in other buildings. While the current IMDS is oriented toward manual, human-based diagnostic techniques, we also evaluated automated diagnostic techniques. Strategies for utilizing results from this demonstration to influence commercial building performance monitoring for commissioning and operations will be discussed. Background</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Philip Haves</style></author><author><style face="normal" font="default" size="100%">Arthur L. Dexter</style></author><author><style face="normal" font="default" size="100%">Jorgensen, D.R.</style></author><author><style face="normal" font="default" size="100%">Keck-Voon Ling</style></author><author><style face="normal" font="default" size="100%">Geng, G.</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Use of a Building Emulator to Develop Techniques for Improved Commissioning and Control of HVAC Systems</style></title><secondary-title><style face="normal" font="default" size="100%">ASHRAE Transactions</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">air conditioning</style></keyword><keyword><style  face="normal" font="default" size="100%">automatic</style></keyword><keyword><style  face="normal" font="default" size="100%">commissioning</style></keyword><keyword><style  face="normal" font="default" size="100%">computer programs</style></keyword><keyword><style  face="normal" font="default" size="100%">controls</style></keyword><keyword><style  face="normal" font="default" size="100%">energy management</style></keyword><keyword><style  face="normal" font="default" size="100%">heating</style></keyword><keyword><style  face="normal" font="default" size="100%">ventilation</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">1991</style></year></dates><volume><style face="normal" font="default" size="100%">97</style></volume><language><style face="normal" font="default" size="100%">eng</style></language><issue><style face="normal" font="default" size="100%">1</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Philip Haves</style></author><author><style face="normal" font="default" size="100%">Arthur L. Dexter</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Use of a Building Emulator to Evaluate Control Strategies Implemented in Commercial BEMS</style></title><secondary-title><style face="normal" font="default" size="100%">Building Environmental Performance &#039;91</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">1991</style></year><pub-dates><date><style  face="normal" font="default" size="100%">04/1991</style></date></pub-dates></dates><pub-location><style face="normal" font="default" size="100%">Cantebury, England</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Hossein Vaezi-Nejad</style></author><author><style face="normal" font="default" size="100%">E. Hutter</style></author><author><style face="normal" font="default" size="100%">Philip Haves</style></author><author><style face="normal" font="default" size="100%">Arthur L. Dexter</style></author><author><style face="normal" font="default" size="100%">George E. Kelly</style></author><author><style face="normal" font="default" size="100%">Pierre Nusgens</style></author><author><style face="normal" font="default" size="100%">Shengwei Wang</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Use of Building Emulators to Evaluate the Performance of Building Energy Management Systems</style></title><secondary-title><style face="normal" font="default" size="100%">Building Simulation &#039;91</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">1991</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/1991</style></date></pub-dates></dates><pub-location><style face="normal" font="default" size="100%">Nice, France</style></pub-location><pages><style face="normal" font="default" size="100%">209-213</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Three complementary approaches may be used in the evaluation of the performance of building control systems-simulation, emulation and field testing. In emulation a real-time simulation of the building and HVAC plant is connected to a real building energy management system (BEMS) via a hardware interface. Emulation has the advantage of allowing controlled, repeatable experiments whilst testing real devices that may contain proprietary algorithms. Building emulators have been developed by the authors in the context of lEA Annex 17, which is concerned with the use of simulation to evaluate the performance of BEMS. The paper discusses different approaches to the design of building emulators and describes the different architectures, hardware and software used by the authors. The problem of evaluating the overall performance of BEMS is discussed and results are presented that illustrate the use of emulators to investigate the influence of the tuning of local loop controls on building performance.&lt;/p&gt;</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Joseph H. Eto</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">On Using Degree-days to Account for the Effects of Weather on Annual Energy Use in Office Buildings</style></title><secondary-title><style face="normal" font="default" size="100%">Energy and Buildings</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">1988</style></year><pub-dates><date><style  face="normal" font="default" size="100%">09/1988</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">12</style></volume><abstract><style face="normal" font="default" size="100%">&lt;p&gt;To better quantify the effects of conservation measures, degree.day-based techniques are commonly used to isolate weather.induced changes in building energy use. In this paper, we use a building energy simulation model, which allows us to hold fixed all influences on energy use besides weather, to evaluate several degree-day-based techniques. The evaluation is applied to simulated electricity and natural gas consumption for two large office building prototypes located in five U.8. climates. We review the development of degree day- based, weather-normalization techniques to identify issues for applying the techniques &lt;strong&gt;to &lt;/strong&gt;office buildings and then evaluate the accuracy of the techniques with the simulated data. We conclude that, for the two office building prototypes and five U.8. locations examined, most techniques perform reasonably well; accuracy, in predicting annual consumption, is generally better than 10%. Our major finding is that accuracy among individual techniques is overwhelmed by circumstances outside the control of the analyst, namely, the choice of the initial year from which the normalization estimates are made.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue><section><style face="normal" font="default" size="100%">113</style></section></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Arthur L. Dexter</style></author><author><style face="normal" font="default" size="100%">Mahroo M. Eftekhari</style></author><author><style face="normal" font="default" size="100%">Philip Haves</style></author><author><style face="normal" font="default" size="100%">Fábio Gonçalves Jota</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">The Use of Dynamic Simulation Models to Evaluate Algorithms for Building Energy Control: Experience with HVACSIM+</style></title><secondary-title><style face="normal" font="default" size="100%">International Congress on Building Energy Management</style></secondary-title><tertiary-title><style face="normal" font="default" size="100%">Proceedings of ICBEM’87</style></tertiary-title></titles><dates><year><style  face="normal" font="default" size="100%">1987</style></year><pub-dates><date><style  face="normal" font="default" size="100%">09/1987</style></date></pub-dates></dates><pub-location><style face="normal" font="default" size="100%">Lausanne, Switzerland</style></pub-location><volume><style face="normal" font="default" size="100%">8</style></volume><language><style face="normal" font="default" size="100%">eng</style></language></record></records></xml>