<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>46</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Evan Mills</style></author><author><style face="normal" font="default" size="100%">Jessica Granderson</style></author><author><style face="normal" font="default" size="100%">Wanyu R. Chan</style></author><author><style face="normal" font="default" size="100%">Richard C. Diamond</style></author><author><style face="normal" font="default" size="100%">Philip Haves</style></author><author><style face="normal" font="default" size="100%">Bruce Nordman</style></author><author><style face="normal" font="default" size="100%">Paul A. Mathew</style></author><author><style face="normal" font="default" size="100%">Mary Ann Piette</style></author><author><style face="normal" font="default" size="100%">Gerald Robinson</style></author><author><style face="normal" font="default" size="100%">Stephen E. Selkowitz</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Green, Clean, &amp; Mean: Pushing the Energy Envelope in Tech Industry Buildings</style></title></titles><dates><year><style  face="normal" font="default" size="100%">2015</style></year><pub-dates><date><style  face="normal" font="default" size="100%">05/2015</style></date></pub-dates></dates><publisher><style face="normal" font="default" size="100%">Lawrence Berkeley National Laboratory</style></publisher><abstract><style face="normal" font="default" size="100%">&lt;p&gt;When it comes to innovation in energy and building performance, one can expect leading-edge activity from the technology sector. As front-line innovators in design, materials science, and information management, developing and operating high-performance buildings is a natural extension of their core business.&lt;/p&gt;&lt;p&gt;The energy choices made by technology companies have broad importance given their influence on society at large as well as the extent of their own energy footprint. Microsoft, for example, has approximately 250 facilities around the world (30 million square feet of floor area), with significant aggregate energy use of approximately 4 million kilowatt-hours per day.&lt;/p&gt;&lt;p&gt;There is a degree of existing documentation of efforts to design, build, and operate facilities in the technology sector. However, the material is fragmented and typically looks only at a single company, or discrete projects within a company.Yet, there is no single resource for corporate planners and decision makers that takes stock of the opportunities and documents sector-specific case studies in a structured manner. This report seeks to fill that gap, doing so through a combination of generalized technology assessments (“Key Strategies”) and case studies (“Flagship Projects”).&lt;/p&gt;</style></abstract><custom2><style face="normal" font="default" size="100%">LBNL-1005070E</style></custom2></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Liping Wang</style></author><author><style face="normal" font="default" size="100%">Paul A. Mathew</style></author><author><style face="normal" font="default" size="100%">Xiufeng Pang</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Uncertainties in energy consumption introduced by building operations and weather for a medium-size office building</style></title><secondary-title><style face="normal" font="default" size="100%">Energy and Buildings</style></secondary-title><short-title><style face="normal" font="default" size="100%">Energy and Buildings</style></short-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Building Operations</style></keyword><keyword><style  face="normal" font="default" size="100%">energyplus</style></keyword><keyword><style  face="normal" font="default" size="100%">Monte Carlo Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Uncertainties</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2012</style></year><pub-dates><date><style  face="normal" font="default" size="100%">10/2012</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">53</style></volume><pages><style face="normal" font="default" size="100%">152 - 158</style></pages><custom2><style face="normal" font="default" size="100%">LBNL-5888E</style></custom2></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Brian E. Coffey</style></author><author><style face="normal" font="default" size="100%">Sam Borgeson</style></author><author><style face="normal" font="default" size="100%">Stephen E. Selkowitz</style></author><author><style face="normal" font="default" size="100%">Joshua S. Apte</style></author><author><style face="normal" font="default" size="100%">Paul A. Mathew</style></author><author><style face="normal" font="default" size="100%">Philip Haves</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Towards a Very Low Energy Building Stock: Modeling the US Commercial Building Stock to Support Policy and Innovation Planning</style></title><secondary-title><style face="normal" font="default" size="100%">Building Research and Information</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2009</style></year></dates><volume><style face="normal" font="default" size="100%">37:5</style></volume><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;This paper describes the origin, structure and continuing development of a model of time varying energy consumption in the US commercial building stock. The model is based on a flexible structure that disaggregates the stock into various categories (e.g. by building type, climate, vintage and life-cycle stage) and assigns attributes to each of these (e.g. floor area and energy use intensity by fuel type and end use), based on historical data and user-defined scenarios for future projections. In addition to supporting the interactive exploration of building stock dynamics, the model has been used to study the likely outcomes of specific policy and innovation scenarios targeting very low future energy consumption in the building stock. Model use has highlighted the scale of the challenge of meeting targets stated by various government and professional bodies, and the importance of considering both new construction and existing buildings.&lt;/p&gt;</style></abstract><section><style face="normal" font="default" size="100%">610</style></section></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>10</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Tianzhen Hong</style></author><author><style face="normal" font="default" size="100%">Dale A. Sartor</style></author><author><style face="normal" font="default" size="100%">Paul A. Mathew</style></author><author><style face="normal" font="default" size="100%">Mehry Yazdanian</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Comparisons of HVAC Simulations between EnergyPlus and DOE-2.2 for data centers</style></title><secondary-title><style face="normal" font="default" size="100%">ASHRAE Conference</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">data center</style></keyword><keyword><style  face="normal" font="default" size="100%">doe-2</style></keyword><keyword><style  face="normal" font="default" size="100%">energy performance</style></keyword><keyword><style  face="normal" font="default" size="100%">energyplus</style></keyword><keyword><style  face="normal" font="default" size="100%">simulation</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2009</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">115 Part 1</style></volume><language><style face="normal" font="default" size="100%">eng</style></language></record></records></xml>