Line 15: | Line 15: |
1. Windows 32 bit: [[attachment:win32.zip]] | 1. Click on [[attachment:bcvtb_win32.zip]] to download the bcvtb.dll for Windows 32 bit. 1. Click on [[attachment:bcvtb_win64.zip]] to download the bcvtb.dll for Windows 64 bit. |
This page describes how to fix a bug in the dll of EnergyPlus 7.1.0, build12 that may occur when exchanging a large amount of data in each time step. The error message that EnergyPlus writes to its .err file is
ExternalInterface starts first data exchange. Error: No digits were found in getDoubleCheckError. Further characters after number: Sending EXIT_FAILURE = : 1 **FATAL:Error in ExternalInterface: Check EnergyPlus *.err file.
To fix the bug, proceed as follows:
Windows
- Install the BCVTB version 1.1.0
Download the bcvtb.dll for your architecture and copy it to the EnergyPlus directory, such as C:\Program Files\EnergyPlus-7-0-0. This will replace the existing file with the same name.
Click on bcvtb_win32.zip to download the bcvtb.dll for Windows 32 bit.
Click on bcvtb_win64.zip to download the bcvtb.dll for Windows 64 bit.